background image

6

The finishing panels provided (to be installed on the long front 
side and also on the back, on mod. 180x90)  ensure adequate 
ventilation, which is necessary for the air-water mixture during 
the whirlpool use, while also allowing access to the electrome-
chanical parts under the tub.
  Jacuzzi® panels ensure that it is possible to inspect the de-
vices installed under the tub for any maintenance which may be 
required. It is therefore not advisable to perform recessed instal-
lation or to use other panelling systems. 

 

NOTE for mod. 180x90:

 

If the tub is installed with the back 

against the wall, it is more difficult to access devices located under 
the back, even if access is not completely prevented.

Electrical safety

Jacuzzi®” hydromassage products are safe appliances, manufac-
tured according to 

EN 60335.2.60, EN 55014 and EN 55014-2

.

They are tested during production to guarantee user safety.
Installation must be carried out by qualified and authorized per-
sonnel, in compliance with current national provisions.

  

It is the responsibility of the installer to select proper 
materials, carry out the work correctly and check the 
condition of the system to which the unit will be con-
nected and the unit itself in order to ensure user safety. 

 

 

Jacuzzi® whirlpool baths are Class “1” appliances and thus must 
be securely anchored and permanently connected to the electric 
mains and earth system 

without any intermediate connections

.

  

The electrical system and earth system of the building 
must be in working order and must comply with the le-
gal provisions and specific regulations in force in the 
country of use.

  

An appropriate device must be provided, as part of the 
fixture and installed in compliance with current regu-
lations, which disconnects the equipment from the 
mains.

For connection to the mains, it is necessary to install a disconnect-
ing multiple-pole switch that provides full disconnection under 
overvoltage category III conditions and place it in an area that com-
plies with the safety prescriptions for bathrooms. 

  

The switch and other electrical devices must be located, 
in compliance with regulations, in an area that cannot 
be reached by the person using the appliance.

  

If the building’s electrical system is not able to guaran-
tee a stabile power supply, it is recommended to install 
a voltage stabiliser that suitably dimensioned for the 
required power upstream of the equipment.

The installation of electrical devices and other equipment (sock-
ets, switches, etc.) in the bathroom must be in strict accordance 
with the legal requirements and regulations for each country. In 
particular, no electrical installations are to be made within the 
area surrounding the appliance in a range of 60 cm horizontally 
and 225 cm vertically.

2

2

3

3

0

1

3

0

1

0,6 m

0,6 m

0,6 m

2,25 m

Connection to the electrical system of the building must be 
made using a sheathed cable with characteristics not inferior to 
type 

H 05 VV-F 3x2.5 mm

2

.

 

 

The appliance comes equipped with an LED lighting system, in 
compliance with Regulation 

EN 62471:2009

.

  

The electrical system of the building must be equipped 
with a 0.03 A differential switch.

  

Parts which contain electrical components, with the 
exception of remote control devices, must be placed or 
attached in such a way so they do not fall into the tub. 
Powered components and appliances must be accessi-
ble to those persons in the tub.

   

The Jacuzzi® whirlpool baths are fitted with a terminal, 
located near the pump and labelled with the symbol 

, for the equipotential connection of the surround-

ing metal components, as required by EN 60335.2.60 
standards. 

 

 WARNING: Disconnect electrical power supply to the tub 
before any servicing operation.

6

Summary of Contents for J-SHA

Page 1: ...zione Instructions for preinstallation Fiche tecnique de pre installation Vorinstallationsblatt Ficha t cnica de preinstalaci n Vasche idro Whirlpool baths Baignoires d hydromassage Whirlpoolwannen Ba...

Page 2: ...gs are not scaled Avertissements Toutes les mesures sont exprim es en centim tres Les dessins report s ne sont pas l chelle Warnung S mtliche Ma angaben in cm Die Zeichnungen sind nicht im Ma stab Adv...

Page 3: ...sta rif scheda rispettiva e che sia stato opportunamente dimensionato Alcuni modelli prevedono l installazione di un sistema d il luminazione a pavimento fare riferimento alla rispettiva scheda di pre...

Page 4: ...rete si impone l installazione di un interrut tore di sezionamento omnipolare che assicuri la completa discon nessione nelle condizioni della categoria di sovratensione III questo dispositivo deve es...

Page 5: ...m is capable of delivering the required power see respective speci fication sheet and that it is appropriately sized Some models provide for installation of a floor lighting system refer to the respec...

Page 6: ...isconnects the equipment from the mains For connection to the mains it is necessary to install a disconnect ing multiple pole switch that provides full disconnection under overvoltage category III con...

Page 7: ...abitation soit en me sure de distribuer la puissance n cessaire r f fiche sp ci fique et que celle ci soit opportun ment dimensionn e Certains mod les pr voient l installation d un syst me d clairage...

Page 8: ...le raccordement au r seau il est indispensable d installer un interrupteur de sectionnement omnipolaire garantissant une com pl te d connexion dans les conditions de la cat gorie de surten sion III c...

Page 9: ...vorausgesetzt dass die Spannung zwischen den beiden Phasen bei 220 240 V liegt ACHTUNG bei den Modellen mit Heizger t sich davon berzeugen dass die elektrische Anlage des Geb udes die erforderliche Le...

Page 10: ...Stromnetz muss eine geeignete Vorrichtung vorgesehen sein die fes ten Bestandteil der Anlage bildet und gem den gel tenden Bestimmungen zu installieren ist F r den Netzanschluss ist ein allpoliger Tre...

Page 11: ...resedequelainstalaci nel ctricadeledificiopueda suministrarlapotenciarequerida ref fichacorrespondiente yquehayasidodimensionadacorrectamente Algunos modelos prev n la instalaci n de un sistema de ilu...

Page 12: ...as vigentes que desconecte el equipo de la red el ctrica Para la conexi n a la red es necesario instalar un interruptor de cor te omnipolar que garantice la completa desconexi n en las condi ciones de...

Page 13: ...13 Jacuzzi Jacuzzi Europe S p A 50 c 6 6a 6b 6c 45 c 1 Y Aquasoul J Sha Sharp Maxima 2 220 240 2 220 240 2 IEC 60335 1 A2 600 a 6 X 3 3a 3b DB EN 1717 15 14 4 4a 14 1 2 5 13...

Page 14: ...a J Sha Mi J Sha Mi Corner B 180x90 Jacuzzi C 180x90 Jacuzzi EN 60335 2 60 EN 55014 EN 55014 2 Jacuzzi 1 III 60 225 c 2 2 3 3 0 1 3 0 1 0 6m 0 6m 0 6m 2 25 m H 05 VV F 3x2 5 2 EN 62471 2009 0 03 A Jac...

Page 15: ...15 EN 60335 2 60...

Page 16: ...A Company of Jacuzzi Brands Corp USA Jacuzzi Bathroom Espa a C Comte urgell 252 local 4 08036 Barcelona Phone 34 932 385 031 Fax 34 932 385 032 www jacuzzi es info es jacuzzi eu I dati e le caratteris...

Reviews: