6
The finishing panels provided (to be installed on the long front
side and also on the back, on mod. 180x90) ensure adequate
ventilation, which is necessary for the air-water mixture during
the whirlpool use, while also allowing access to the electrome-
chanical parts under the tub.
Jacuzzi® panels ensure that it is possible to inspect the de-
vices installed under the tub for any maintenance which may be
required. It is therefore not advisable to perform recessed instal-
lation or to use other panelling systems.
NOTE for mod. 180x90:
If the tub is installed with the back
against the wall, it is more difficult to access devices located under
the back, even if access is not completely prevented.
Electrical safety
Jacuzzi®” hydromassage products are safe appliances, manufac-
tured according to
EN 60335.2.60, EN 55014 and EN 55014-2
.
They are tested during production to guarantee user safety.
Installation must be carried out by qualified and authorized per-
sonnel, in compliance with current national provisions.
It is the responsibility of the installer to select proper
materials, carry out the work correctly and check the
condition of the system to which the unit will be con-
nected and the unit itself in order to ensure user safety.
Jacuzzi® whirlpool baths are Class “1” appliances and thus must
be securely anchored and permanently connected to the electric
mains and earth system
without any intermediate connections
.
The electrical system and earth system of the building
must be in working order and must comply with the le-
gal provisions and specific regulations in force in the
country of use.
An appropriate device must be provided, as part of the
fixture and installed in compliance with current regu-
lations, which disconnects the equipment from the
mains.
For connection to the mains, it is necessary to install a disconnect-
ing multiple-pole switch that provides full disconnection under
overvoltage category III conditions and place it in an area that com-
plies with the safety prescriptions for bathrooms.
The switch and other electrical devices must be located,
in compliance with regulations, in an area that cannot
be reached by the person using the appliance.
If the building’s electrical system is not able to guaran-
tee a stabile power supply, it is recommended to install
a voltage stabiliser that suitably dimensioned for the
required power upstream of the equipment.
The installation of electrical devices and other equipment (sock-
ets, switches, etc.) in the bathroom must be in strict accordance
with the legal requirements and regulations for each country. In
particular, no electrical installations are to be made within the
area surrounding the appliance in a range of 60 cm horizontally
and 225 cm vertically.
2
2
3
3
0
1
3
0
1
0,6 m
0,6 m
0,6 m
2,25 m
Connection to the electrical system of the building must be
made using a sheathed cable with characteristics not inferior to
type
H 05 VV-F 3x2.5 mm
2
.
The appliance comes equipped with an LED lighting system, in
compliance with Regulation
EN 62471:2009
.
The electrical system of the building must be equipped
with a 0.03 A differential switch.
Parts which contain electrical components, with the
exception of remote control devices, must be placed or
attached in such a way so they do not fall into the tub.
Powered components and appliances must be accessi-
ble to those persons in the tub.
The Jacuzzi® whirlpool baths are fitted with a terminal,
located near the pump and labelled with the symbol
, for the equipotential connection of the surround-
ing metal components, as required by EN 60335.2.60
standards.
WARNING: Disconnect electrical power supply to the tub
before any servicing operation.
6
Summary of Contents for J-SHA
Page 15: ...15 EN 60335 2 60...