41
Troubleshooting...
lack of electric energy
command not accepted
insufficient water level
1
lack of electric energy
the selected hydromassage pro-
gramme is finished
(each programme
has its own duration, after which time,
the hydromassage stops on its own)
insufficient water level
1
- check that the main switch is not off and/
or that the system is not faulty (contact your
trusted electrician)
- try to keep the key on the remote control held
down again (also follow the instructions in the
relative chapters)
- add water until it covers the highest nozzles
on the backrest, so they are immersed and
keep the key held down once again
- check that the main switch is not off and/
or that the system is not faulty (contact your
trusted electrician)
- where desired, re-start the hydromassage (re-
fer to the relative chapter)
- add water and restore to the level; if the func-
tion does not automatically re-start, re-start it
by holding the relative key down once again.
Hydromassage
does not start
The hydromassage stops
of its own accord
W
e always recommend carefully reading the manual before using your tub; in the instance
that there is an issue, refer to the following guide (some operation faults are presented
on the J.touch remote control display by the switching on and/or flashing of remote control
keys).
the outlet nozzles are closed
poor hydromassage intensity
obstructed air outlets and/or hydro-
massage
- open the nozzles (refer to Chapter “prelimi-
nary operations - some recommendations”)
- use "+" on the remote control, as indicated in
the relative chapters.
- clean the outlets as described in the Chap-
ter “Maintenance”; where this is not sufficient,
contact a Jacuzzi® Support Centre.
The "strength" of the hydromas-
sage has got weaker;
not many air bubbles come out of
the larger hydromassage outlets