E
N
G
L
IS
H
MOTOR
SERVICE ACCESS
(WITH INTEGRAL SKIRT)
REMOVABLE SKIRT
ACCESS PANELS
ACCESS AREA
20"
36"
24"
18"
B
A
C
SERVICE ACCESS
(CORNER BATHS)
A - Preferred access
B - Acceptable alternative if access
A
is not possible
C - Additional access for equipment (Optional)
RIGHT HAND UNIT SHOWN
NOTE:
Left hand unit access is on the opposite
side (mirror Image).
(45,7 cm)
(50,8 cm)
(60 cm)
(91,4 cm)
MOTOR
AREA
A
AREA
B
FRONT
In some cases, access may not have been provided because of
the design of the bath environment and having full understanding
that in this case, it may be necessary to remove the unit for service.
If this is the case, diagnosing a problem may not be possible
without complete access to the plumbing system. This would ne-
cessitate the removal of the unit. Although this practice is not com-
monly implemented, it is an acceptable method.
In some cases access may have been provided in Area A but
service is required in Area B which requires the unit to be pulled for
service and reinstalled.
If service access has not been provided, it is the homeowner's
responsibility to remove the bath and provide the required
access, should a repair become necessary.
Service Access
For partially or fully sunken installations, allow for access to ser-
vice connections. It is the installer's responsibility to provide suffi-
cient service access. The recommended minimum dimensions al-
lowable for service to the bath are shown in the "Service Access"
illustration and on the ROUGH-IN drawing for that tub.
Provide adequate area around unit for air circulation for cooling
the motor and to supply sufficient air to the jets. Do not insulate this
area or around motor.
Optional RapidHeat
TM
Service Access
Where tubs have been ordered with the optional RapidHeat
TM
heater consider an additional service access.
If service access has not been provided, it is the home owners
responsibility to remove the bath and provide the required
access, should a repair become necessary.
Service Access with Skirt
An optional skirt fits along the side of the bath for above-floor
installations and is also an access panel for servicing. Allow a space
of at least 8 inches away from the bath for skirt removal.
The skirt is designed to accommodate the added height of the
tile, linoleum, or other floor coverings up to 1-1/4" (31,75 mm) above
the floor, and will be flush with the floor when installed.
More detailed instructions on skirt installation are provided with
the optional skirt assembly.
Service Access with Integral Skirt
Service access is through the removable skirt panels.
MOTOR
18"
18"
12"
ALTERNATE
ACCESS
PREFERRED
ACCESS
SERVICE ACCESS
(WITHOUT SKIRT)
FRONT
(30,5 cm)
12"
(30,5 cm)
(45,7 cm)
(45,7 cm)
18"
12"
SERVICE ACCESS
(BG55, CAPELLA 60 FRONT LEFT MOTOR CORNER BATH ONLY)
Preferred access area
(30,5 cm)
(45,7 cm)
20
Jacuzzi Whirlpool Bath K272000AF 7/06
INSTALLATION INSTRUCTIONS