Jacuzzi Whirlpool Bath K272000AF 7/06
General Whirlpool Bath Troubleshooting Guide
PROBABLE CAUSES
PROBLEM
REMEDY
NOTE: If unit is within the warranty period, contact Jacuzzi Whirlpool Bath Service Support
at 1- (800)- 288-4002 with bath's serial
number before work is started. The Serial Number is located on the Specification/Serial Number Plate. See page 30.
Pump/Motor does not start.
Pump/Motor operates but no fully
adjustable jets are functioning.
Pump/Motor operates but air is not
injected into water.
Pump/motor does not shutoff.
Water leakage from pump unions.
Pump/motor shuts off by itself or with
wall timer, before set time elapses.
No power to pump/motor.
Pump/motor not plugged in.
Magic Touch switch - air tube not
connected to switch or to air switch
on pump/motor.
Pump/motor faulty.
Jets are closed.
Suction cover may be clogged.
Air valves closed.
Magic Touch switch - air tube not
connected to switch or to air switch
on pump/motor.
Motor power cord not connected to
control box.
If a wall timer is used, the timer is
defective
Overtightened, O-ring may be
pinched or improperly seated, under
tightened.
Motor thermal protection has
deactivated pump/motor due to
overheating. (Supply voltage low.)
GFCI tripped.
Inadequate supply wiring.
Reset GFCI.
Insert plug(s) fully into outlet(s). Units
with electronic controls: Motor plugs into
control box and control box plugs into
GFCI receptacle. Units with manual
controls: Motor plugs into GFCI recep-
tacle.
Reconnect tube to Magic Touch switch
or to air switch pump/motor.
Replace pump/motor assembly.
Open jets by rotating counterclockwise.
With motor turned off, remove safety
cover and remove any debris.
Replace
suction cover before operating.
Open air control valves.
Reconnect tube to Magic Touch switch
or to air switch pump/motor.
Reconnect motor power cord to control
box.
Replace timer.
Untighten unions check and reseat O-
ring. If O-ring has been pinched out of
shape, replace (refer to Service Support
number below). When tightening union
nuts,
hand tighten only
.
Let motor cool; thermal protection will
reset. Check for proper ventilation.
(Check supply voltage.)
Reset GFCI. If it continues to trip do not
use this unit. Disconnect the unit and
have the problem corrected by a
licensed electrician before using.
Consult a licensed electrician to correct
wiring to unit.