Cycle Valve Strainer
(Pinnacle, Quantum and Triton Only)
If there is a decreased water flow from the six-jet wave seat, the cycle valve strainer should be cleaned. The spa
must be drained before accessing the strainer. To access the strainer, remove all the screws securing the skirt
indicated. Locate the knurled union and unscrew it. Separate the union from the cycle valve and remove the strainer.
Clean by flushing any debris. After cleaning, replace the strainer by reversing the above procedure. Refill the spa.
Before reinstalling the skirt, check for leaks with the jet pumps operating.
REMOVE THIS PANEL
TO ACCESS STRAINER
FRONT
CYCLE VALVE
UNSCREW THIS UNION
STRAINER
O-RING
18
REMOVE THIS PANEL
TO ACCESS STRAINER
FRONT
PINNACLE
QUANTUM
CYCLE VALVE STRAINER
MAINTENANCE
FRONT
REMOVE THIS PANEL
FOR CYCLE VALVE
STRAINER ACCESS
TRITON
Summary of Contents for Laser
Page 1: ...Platinum Series Spas WHIRLPOOL BATH R Owner s Manual...
Page 26: ...24...