background image

Inspection and Shipping Claim

Check for shipping damage upon receipt of the spa.

Jacuzzi Whirlpool Bath is not responsible for damage to
the spa sustained during shipment.  If damage is evident
before unpacking, refer to instructions regarding ship-
ping claims on the outside of the carton and immediately
file a claim with the carrier.

Once the spa has been removed from the carton

and before it is permanently installed, check the spa
completely for damage.  Fill the shell with water and
operate the system (refer to Operating Instructions) to
check for leaks which may have resulted from improper
shipping or handling.  All Jacuzzi Whirlpool Bath spas
are factory tested for proper operation and water tight
connections prior to shipment.  If leaks or other problems
are detected, immediately notify your Jacuzzi Whirlpool
Bath dealer, Authorized Service Agent, or call Jacuzzi
Whirlpool Bath, (800) 288-4002 for Warranty Service.

NOTE:  Damage or defects which could have been
discovered and repaired prior to installation and
which are claimed after final installation of the spa,
are excluded from our warranty.

5

Positioning Your Spa

Because your spa is portable, you can locate it just

about anywhere you wish—on a deck, patio, or even
indoors.  Just be sure to position it above ground in an
area with good drainage and on a level, continuous
surface which can support the weight of the spa when
filled with water and people.  You must also provide
access to the spa's equipment for service and general
maintenance.  See specifications sheet for minimum
service access requirements.

Electrical Requirements

Your Platinum Series spa (except the Triton) re-

quires a 230 VAC, 50 AMP, 4-wire, grounded type GFCI
protected electrical service with copper conductors, and
must be in a separate circuit having no other appliance
connected in that circuit.  If you do not have this kind of
circuit, a qualified electrician should install the neces-
sary wiring.  A wiring diagram is provided on the inside
cover of the electrical control box.  Inadequately sized
wiring may cause the unit to malfunction and bring about
permanent damage to the spa’s electrical system.  The
circuit must also have a ground wire in order to take
advantage of the designed-in safety features of the spa.
A bond wire must also be used.  Bond according to
procedure described on the next page.

WARNING:  Without proper grounding and bonding,
a system malfunction may cause fatal shock.

INSTALLATION

Summary of Contents for Laser

Page 1: ...Platinum Series Spas WHIRLPOOL BATH R Owner s Manual...

Page 2: ...ery Use care when entering and exiting DANGER Risk of child drowning Do not permit children to use this product unless they are closely supervised The use of a locked cover is highly recommended to pr...

Page 3: ...Pinnacle Triton Only __________________________________________ 14 Maintenance Water Quality and Water Chemistry __________________________________________ 15 Filtration _____________________________...

Page 4: ...950 lb 432 kg ELECTRICAL REQUIREMENTS 230 VAC 4 Wire 50 AMP 60 Hz GFCI Protected Dedicated Separate Circuit OPERATING GALLONAGE 550 U S gal 2082 liters TOTAL WEIGHT FLOOR LOADING 6732 lb 3060 kg 105 l...

Page 5: ...dicated Separate Circuit OPERATING GALLONAGE 375 U S gal 1419 liters TOTAL WEIGHT FLOOR LOADING 4771lb 2169 kg 105 lb sq ft 512 kg m2 Product specifications are subject to change without notice 3 PLAT...

Page 6: ...GFCI Protected Dedicated Separate Circuit OPERATING GALLONAGE 390 U S gal 1477 liters TOTAL WEIGHT FLOOR LOADING 5335 lb 2420 kg 104 lb sq ft 509 kg m2 TRITON Product specifications are subject to ch...

Page 7: ...Spa Because your spa is portable you can locate it just about anywhere you wish on a deck patio or even indoors Just be sure to position it above ground in an area with good drainage and on a level co...

Page 8: ...Outdoor Installation If you install the spa outdoors we recommend that you provide a concrete pad for it to rest on To do this construct forms for a 4 thick level pad Install a 10 gauge wire mesh 6 x...

Page 9: ...s normal operating level which is to the water level indicator mark on the skimmer frame Turn ON the circuit breakers at the main electrical panel At the control panel on the spa rim press the JETS bu...

Page 10: ...on pump and heater could be irreparably damaged Not heeding this caution will nullify the warranty In addition to damaging the unit operating the spa with insufficient water could cause a fire 8 Initi...

Page 11: ...is started with this button it will automatically stop after 30 minutes of operation Blower Starts or stops the blower for aeration in the spa Blower operates in all functions The blower will also au...

Page 12: ...ill not be activated Panel Lock The panel lock is provided to prevent tampering with the control panel When the panel lock is engaged all the automatic spa functions will operate normally Press these...

Page 13: ...tonsaredeactivated Whenpressed the set temperature will appear with a double arrow next to it Display Messages These are some of the messages you will see on the center display Message Meaning Battery...

Page 14: ...urth press of the button will turn the light OFF The lights automatically turn OFF after 4 hours of operation The remote batteries have an anticipated life of 3 years depending on usage If batteries n...

Page 15: ...im For maximum air induction rotate each control knob fully counter clockwise to the largest circle For fewer air bubbles decrease the amount of air induction by rotating the control knobs clockwise W...

Page 16: ...installation instructions NOTE the quality of AM reception will vary by locality Jacuzzi Whirlpool Bath is not responsible for the quality of AM reception PUSH DOOR CLOSED TO LATCH PUSH HERE OPEN OUTE...

Page 17: ...tured in the filters may bring about various undesirable water quality conditions These conditions can be corrected with the use of spa treatment chemicals which are available from your Jacuzzi Whirlp...

Page 18: ...150 gallons of spa water Scrub the spa surfaces with this solution to remove any oily deposits This will ensure that any bacteria or algae which are resistant to the normal disinfectant level are kil...

Page 19: ...k for collection of debris such as leaves hair etc and cleaned as necessary To clean the basket remove it from the skimmer by pulling it out then backflush it with water from a garden hose and reinsta...

Page 20: ...d unscrew it Separate the union from the cycle valve and remove the strainer Clean by flushing any debris After cleaning replace the strainer by reversing the above procedure Refill the spa Before rei...

Page 21: ...this page as long periods without maintenance of water quality could be detrimental to the spa Another means of maintaining minimum water qual ity while away for less than two weeks is to follow the...

Page 22: ...t cloth and wiped clean Use sparingly in small amounts to avoid contaminating the spa water If the water line is heavily soiled it may be advisable to lower the water level 2 3 inches before cleaning...

Page 23: ...h content of solids in water F Filter motor plug not connected to the electrical cabinet A Leak in suction line discharge line or connections B Excessive evaporation and or splashing A Low water level...

Page 24: ...line C Vibrating parts attached to motor or support brackets D Low water level E Damaged or worn motor bear ings F Impeller rubbing inside case G Debris inside pump A Worn or damaged pump seal A Power...

Page 25: ...SPA SHELL SAVE FOR LATER REINSTALLATION IF DESIRED CUT PIPE HERE INSTALL AND CEMENT 3 4 PVC CAP HERE TEE LOCATED ON DISCHARGE PIPING SUGGESTED MODIFICATION REFER TO LOCAL CODES FOR REQUIREMENTS 1 1 2...

Page 26: ...24...

Page 27: ...e time of delivery All other spa components including the wood cabinet factory installed ozone generator and stereo system including CD player speakers grills etc are warranted against malfunction due...

Page 28: ...itation anyofthefollowing connections supplied by the installer of the equipment improper voltage supply or unauthorized electrical modification incorrect operation or lack of proper routine maintenan...