21
Maximum absorption of the system (
L
ODGE
M, L, S)
(k): at 230 V
- (j): absorbed power
(
): with 3 kW heater
(x): see Chapter. “Electrical preparations”
Q
“
BLOWER
WITH
HEATER
/
HEAT
EXCHANGER
”
VERSION
Power supply (x)
Total consumption
(with heater)
Total consumption
(with heat exchanger)
Spa-Pak
(optional)
Volt
220-240 ~ 50/60 12(16
)
(k)
3,7
(k)
2,7(3,7
)
(j)
0,85
(j)
2,5
(k)
Hertz
Ampere
Ampere
kW
kW
Ampere
0,5
(j)
kW
Q
“
HYDRO
WITH
HEATER
/
HEAT
EXCHANGER
”
VERSION
Power supply (x)
Total consumption
(with heater)
Total consumption
(with heat exchanger)
Spa-Pak
(optional)
Volt
220-240 ~ 50/60 17 (21
)
(k)
8,8
(k)
3,85 (4,85
)
(j)
1,95
(j)
2,5
(k)
Hertz
Ampere
Ampere
kW
kW
Ampere
0,5
(j)
kW
Q
“
HYDRO
WITH
HEATER
”
VERSION
FOR
J
ACUZZI
®
ECO
-
HEAT
/
COOL
POWER
HEAT
PUMP
Power supply (x)
Total consumption
(with heater)
Spa-Pak
(optional)
Volt
220-240 ~ 50/60 16 (20,5
)
(k)
3,7 (4,7
)
(j)
2,5
(k)
Hertz
Ampere
kW
Ampere
0,5
(j)
kW
Q
“
HYDRO
+
BLOWER
WITH
HEATER
/
HEAT
EXCHANGER
”
VERSION
Power supply (x)
Total consumption
(with heater)
Total consumption
(with heat xchanger)
Spa-Pak
(optional)
Volt
220-240 ~ 50/60 20 (24
)
(k)
11
(k)
4,55 (5,55
)
(j)
2,6
(j)
2,5
(k)
Hertz
Ampere
Ampere
kW
kW
Ampere
0,5
(j)
kW
Q
“
HYDRO
+
BLOWER
WITH
HEATER
”
VERSION
FOR
J
ACUZZI
®
ECO
-
HEAT
/
COOL
POWER
HEAT
PUMP
Power supply (x)
Total consumption
(with heater)
Spa-pack
(optional)
Volt
220-240 ~ 50/60 19 (23
)
(k)
4,35 (5,35
)
(j)
2.5
(k)
Hertz
Ampere
kW
Ampere
0.5
(j)
kW
Q
SUPPLEMENTARY
HEATER
(
OPTIONAL
)
Power supply (x)
Total consumption
Volt
220-240 ~ 50/60
26
(k)
6
(j)
Hertz
Ampere
kW
Q
HEAT
EXCHANGER
- Primary inlet MAX temperature ....................................................50 °C
- Connections .......................................................................................... 3/4”
- Primary circuit flow rate ........................................................... 38 l/min
- Primary pressure drop ....................................................... 0,271 M H
2
O
The electrical system that powers the hot tub must
absolutely
be sized for maximum consumption
(as indicated in the respec-
tive tables)
.
Weights
Q
L
ODGE
M
Net weight
average volume
of use
water volume
MAX
Total max. weight
kg
litres
litres
kg
~ 260
~ 880
~ 1100
~ 1360
support
area
concentrated load
on support area
m
2
kg/ m
2
~ 3
~ 453
Q
L
ODGE
L
Net weight
average volume
of use
water volume
MAX
Total max. weight
kg
litres
litres
kg
~ 348
~ 1420
~ 1820
~ 2168
support
area
concentrated load
on support area
m
2
kg/ m
2
~ 3,95
~ 550
Q
L
ODGE
S
Net weight
average volume
of use
water volume
MAX
Total max. weight
kg
litri
litri
kg
~ 245
~ 750
~ 950
~ 1195
support
area
concentrated load
on support area
m
2
kg/ m
2
~ 2,45
~ 488
User safety
Q
If installed by qualified personnel in compliance with the in-
structions in the enclosed installation manual, the system does
not present any risks for the user. However, safety is also contin-
gent upon appropriate use, according to the provisions in the
respective manual, while the user must delegate the operations
described in the installation manual to qualified personnel.
Q
It is important to make sure that personnel tasked to install
or manage the system are qualified as per legal requirements in
effect in the country where installation is carried out.
Q
This appliance uses and generates radio waves. If it is not installed
and used as
indicated, it can interfere with the reception of television and radio
programmes.
However, in special cases this may happen even if the instructions
provided are followed.
Summary of Contents for lodge M
Page 2: ......
Page 7: ...7 20 mm 2 2 4 4 5 5 1 3 3 6 7...
Page 12: ...12 3 4 IN OUT 10 C 30 10 7 C 3 4 IN 10 77 10 45 C C OUT 10C 10B LODGE S LODGE L cm cm...