23

Q

Models with Jacuzzi® Eco-Heat/CoolPower heat pump 

(

11a-11b-11c

) The heat pump can be positioned anywhere as 

long as it is no further than 10 m away from the hot tub.
  The heat pump must be installed in such a way that it cannot 
be accessed by anyone without using keys or tools, and it must 
be protected from water and weathering (it must also be suit-
ably ventilated).
  For more information, see the documentation provided with 
the heat pump.

  

If the hot tub is connected, for periodic filling,  to the 
mains system that supplies drinking water, this con-
nection must be carried out in compliance with the 
EN1717 norm, using “AA”, “AB” or “AD” anti-pollution 
protection procedures. For further information, we 
recommend you contact your water supply company 
and/or your plumber.

 

 

ATTENTION: (IEC 60335-1) The pressure of the hydraulic 
system that supplies the equipment must not exceed 600 
kPa (6 bar); if the equipment is provided with one or more 
solenoid valves for the water supply, the pressure must 
have a minimum value of 35 kPa (0.35 bar).

Q

The customer must make provisions for a ground drainage 

point of suitable dimensions and that can be inspected for any 
cleaning that may be required (

 

8a-8b-8c, det. P1

).

Q

Models with the Jacuzzi® Performance spa-pack: 

connec-

tion must also be provided to the drain for periodic backwash 
and possible emptying of the sand filter installed on the spa-
pak, as well as electrical and plumbing connection between the 
spa-pak and the MaxiJacuzzi® (see the corresponding installa-
tion manual). 

   

CAUTION: Before preparing the drainage point, con-
tact your local authority for information on the regula-
tions for draining chemically treated water.

Q

 (

 

8a-8b-8c,

) Especially if the 

installation is performed in-

side

, it is recommended to

 install a collection pit (

P2/P3

) below 

the base of the

hot tub

(which will be perforated).As there is a 

large amount of water in the hot tub, this is a useful precaution 
if water accidentally escapes and collects inside the base itself.

NOTES: 

- The collection pit will be connected to the main drain pit.

(

8a-8b-8c, detail A

)  For periodic emptying of the hot tub, 

proceed as follows: connect a hose to the drain valve, first re-
moving the plug and screw on the fitting with its gasket. 

NOTE:

 

if you decide to connect the hot tub permanently to the 

ground drainage point, we recommend you install a valve below, 
bypassing the valve installed in the factory.

Electrical preparations

Q

The electrical connection for the hot tub (

8a-8b-8c, part.B/

B1

) can be made as follows:

Models equipped with "Easy Mini" electric box

 

- single-phase line (220-240V 1~)

 

 -  three-phase line consisting of 2 phase cond neutral 

conductor (380-415V 2N~)

Models equipped with "VS2" electric box

 

- single-phase line (220-240V 1~)

 

 -  three-phase line consisting of 2 phase cond neutral 

conductor (380-415V 2N~)

 

 -  three-phase line consisting of 3 phase cond neutral 

conductor (380-415V 3N~)

Q

The rated power supply voltage of the equipment is al-

ways 220-240V.

Q

The equipment can also be installed in Countries where 

the 220-240V voltage is supplied by a two-phase system. For 
the connection please refer to the instruction manual.

Q

The installer must in any case use properly protected cables 

with a suitable cross-section 

(220-240 V~: min. 4 mm

; 380-415 

V~: min. 2,5 mm

2

)

, with characteristics not inferior to type H 05 

VV-F.

Q

Models with the Performance spa-pak:  

provide a cable for 

the electrical connection of the spa-pak pump to the hot tub 
box.

Q

Models with heat exchanger 

Connect the electrical box for 

the hot tub with the devices that control the circulation of the 
hot water in the primary heat exchanger circuit 

(see the wiring 

diagram, installation manual)

. For this purpose, there is a termi-

nal (220-240V/16A) in the electrical box to which the circulation 
pump or other equivalent device can be connected.

  

Position the pipes that power the exchanger away 
from the electric power supply cable.

Q

Models with a supplementary heater (optional):  

prepare a 

separate power supply line (

220-240 V~: min. 4 mm

2

); this line 

may be prepared near the main line (or the one that supplies the 
hot tub, see (

8a-8b-8c, det.B

).

Refer to the respective manual for the correct installation of the 
heater.

Q

Models with Jacuzzi® Eco-Heat/CoolPower heat pump: 

provide an electric cable for connecting the pump to the electric 
box. 

(for more information, see the documentation provided with 

the heat pump).

Q

Provision of a timer with time switch - "silence" function

(Only models with VS2 electronic box)

This function prevents the automatic start of the pumps (filtering 

Summary of Contents for lodge M

Page 1: ...ns for preinstallation KEEP CAREFULLY Fiche tecnique de pre installation CONSERVER AVEC SOIN Vorinstallationsblatt SORGF LTIG AUFBEWAHREN Ficha t cnica de preinstalaci n CONSERVAR CON CUIDADO LODGE M...

Page 2: ......

Page 3: ...ITALIANO 16 ENGLISH 20 FRAN AIS 25 DEUTSCH 30 ESPA OL 34 39 Disegni 4 15 Drawings 4 15 Dessins 4 15 Zeichnungen 4 15 Dibujos 4 15 4 15 LODGE M L S LODGE M L S PERFORMANCE LODGE M L S ECOHEAT COOLPOWER...

Page 4: ...ion version idro Version Hydro versi n hidr omasaje idro LODGE L versione idro hydro version version idro Version Hydro versi n hidr omasaje idro silverwood silverwood built in built in cm cm Tolleran...

Page 5: ...version idro Version Hydro versi n hidr omasaje idro silverwood built in cm 2 built in silverwood Tolleranza dimensionale e o di rettilineit 13 mm Dimensional and or straightness tolerance 13 mm Tol r...

Page 6: ...6 A A A A A 5 4 3 vedere Posizionamento della spa see Positioning the hot tub voir Positionnement du spa siehe Aufstellen desWhirlpools v ase Colocaci n de la minipiscina...

Page 7: ...7 20 mm 2 2 4 4 5 5 1 3 3 6 7...

Page 8: ...1 2 3 4 B B A B P2 P2 P1 12 max A 8 e 8 8A cm LODGE M timer cap Predisposizioni elettriche timer chp Electrical preparations minuteur chap Pr parations lectriques Timer Kap Elektrische Vorbereitungen...

Page 9: ...L 1 5m P2 B 12 max A B P1 14 e 14 A P2 8B cm LODGE L timer cap Predisposizioni elettriche timer chp Electrical preparations minuteur chap Pr parations lectriques Timer Kap Elektrische Vorbereitungen...

Page 10: ...1 e B B1 46 46 A P2 P3 185 22 165 7 P3 P2 P2 B1 B 25 37 8C cm LODGE S timer cap Predisposizioni elettriche timer chp Electrical preparations minuteur chap Pr parations lectriques Timer Kap Elektrische...

Page 11: ...11 X1 X2 MAX 4 m AP AP AP 9 X1 cm X2 cm LODGE M 13 LODGE L 23 LODGE S 20 3 4 IN OUT 53 10 38 10 C C 10A LODGE M LODGE M L LODGE S cm...

Page 12: ...12 3 4 IN OUT 10 C 30 10 7 C 3 4 IN 10 77 10 45 C C OUT 10C 10B LODGE S LODGE L cm cm...

Page 13: ...dels without full foam mod les sans full foam Modelle ohne full foam modelos sin full foam full foam LODGE M ECOHEAT COOLPOWER LODGE M ECOHEAT COOLPOWER modelli con full foam models with full foam mod...

Page 14: ...foam models without full foam mod les sans full foam Modelle ohne full foam modelos sin full foam full foam modelli con full foam models with full foam mod les avec full foam Modelle mit full foam mod...

Page 15: ...ll foam models without full foam mod les sans full foam Modelle ohne full foam modelos sin full foam full foam modelli con full foam models with full foam mod les avec full foam Modelle mit full foam...

Page 16: ...i elet tromeccanici e le tubazioni sono contenuti entro il perimetro Lo skimmer contiene 1 cartuccia filtrante superficie filtrante 4 6 m2 50 ft2 che garantisce un ottima filtrazione dell acqua Assorb...

Page 17: ...icurare uno spazio ottimale per la rimozione dei pannelli e le eventuali manu tenzioni nonch garantire l accesso alle apparecchiature presenti nel vano vasca Il sito in cui verr installata la spa va p...

Page 18: ...re di calore 10a 10b 10c part C Forare la base della minipiscina nel punto indicato per predi sporre l alimentazione dello scambiatore Q Prevedere anche il collegamento del circuito primario con l imp...

Page 19: ...orre un cavo per il collegamento elettrico della pompa alla cassetta elettrica per i dettagli fare riferimento alla documentazione allegata alla pompa di calore Q Predisposizione di un timer o interru...

Page 20: ...riche del gas eventuali pedane metalliche perimetrali ecc Q L apparecchiatura provvista di sistema d illuminazione a led conforme alle norme EN 62471 ATTENZIONE Scollegare l impianto dalla linea di al...

Page 21: ...imary inlet MAX temperature 50 C Connections 3 4 Primary circuit flow rate 38 l min Primary pressure drop 0 271 M H2 O The electrical system that powers the hot tub must absolutely be sized for maximu...

Page 22: ...moved more easily The size of the built in space in the floor is obtained from that of the base of the hot tub 1a 1b 1c NOTE between the floor embedding and the panels it is ad visable to leave enough...

Page 23: ...oving the plug and screw on the fitting with its gasket NOTE if you decide to connect the hot tub permanently to the ground drainage point we recommend you install a valve below bypassing the valve in...

Page 24: ...and that it ensures safe ty of use also concerning maintenance work and the possibility to examine the system Q The Jacuzzi spas are class 1 appliances and therefore they must be permanently connecte...

Page 25: ...tre Le skimmer contient 1 cartouche filtrante surface filtrante 4 6 m2 50 ft2 garantissant une filtration de l eau excel lente Absorption maximale de l installation LODGE M L S k 230 V j puissance ab...

Page 26: ...etien n cessaires N anmoins si l on souhaite installer le spa contre deux murs il faudra imp rativement garantir un espace optimal pour le retrait des panneaux et pour les ventuelles op ra tions d ent...

Page 27: ...l de 1 m les d nivellements sup rieurs risquent de r duire le d bit de la pompe de filtrage Le spa pak doit tre install de mani re ne pas tre accessible aux personnes non munies de cl ou ustensiles et...

Page 28: ...manuel correspondant Q Mod les avec pompe chaleur Jacuzzi EcoHeat Cool Power pr voir un c ble pour le branchement lectrique de la pompe sur le bo tier lectrique pour plus de d tails se r f rer la docu...

Page 29: ...ion lectrique de l immeuble ne serait pas en mesure d assurer une alimentation stable il est conseill d installer un stabilisateur de tension avant l appareil opportun ment dimension n pour la puissan...

Page 30: ...alb des u eren Beckenrandes Der Skimmer enth lt 1 Filterkartusche Filteroberfl che 4 6 m2 50 ft2 welche eine optimale Filterung des Wassers gew hrleis tet Max Stromaufnahme der Anlage LODGE M L S k be...

Page 31: ...t und ge wartet werden k nnen Soll der Whirlpool an mehreren W nden angestellt wer den muss unbedingt ausreichend Platz f r den Ausbau der Paneele und die etwaige Wartung sowie der Zugriff auf die Ger...

Page 32: ...lpool mit einem maximalen H henun terschied von 1 m installiert werden gr ere H henunterschie de k nnen die Leistung der Filterpumpe herabsetzen Der Spa pak muss so installiert werden dass er f r Pers...

Page 33: ...lemme 220 240V 16A vorhan den an die eine Umw lzpumpe oder eine gleichwertigeVorrich tung anzuschlie en ist Die Rohre die den W rmetauscher versorgen m s sen einen ausreichenden Abstand vom Stromkabel...

Page 34: ...so angebracht oder befestigt sein dass sie nicht in die Wanne fallen k nnen Bauteile und Ger te unter Spannung d rfen nicht f r diejenigen die sich im Whirlpool befinden zu g nglich sein Sollte die e...

Page 35: ...electromec nicos y las tuber as caben dentro del per metro El skimmer incorpora 1 cartucho filtrante superficie filtrante 4 6 m2 50 ft2 para garantizar la mejor filtraci n del agua Consumo m ximo de...

Page 36: ...dejar obligatoriamente un espacio adecuado para la retirada de los paneles y las tareas de mantenimiento necesarias as como garantizar el acceso a los aparatos contenidos en el compartimento de la ba...

Page 37: ...a y los fen menos atmosf ricos adem s se debe garantizar una ventilaci n adecuada Q Modelos con intercambiador de calor 10a 10b 10c det C Taladre la base de la minipiscina en el punto indicado para pr...

Page 38: ...la principal es decir la que alimenta la minipiscina v ase 8a 8b 8c det B Para la correcta instalaci n del calentador consulte el manual correspondiente Q Modelos con bomba de calor Jacuzzi EcoHeat C...

Page 39: ...el ctrica del inmueble no permite garantizar una alimentaci n estable se recomienda instalar antes del equipo un estabilizador de tensi n debidamente dimensionado para la potencia del aparato Q Para...

Page 40: ...ak 220 240 50 60 12 16 k 3 7 k 2 7 3 7 j 0 85 j 2 5 k A A A 0 5 j Q IDRO x Spa Pak 220 240 50 60 17 21 k 8 8 k 3 85 4 85 j 1 95 j 2 5 k A A A 0 5 j Q IDRO JACUZZI ECO HEAT COOL POWER x Spa Pak 220 240...

Page 41: ...41 Q LODGE M 260 880 1100 1360 2 2 3 453 Q LODGE L 348 1420 1820 2168 2 2 3 95 550 Q LODGE S 245 750 950 1195 2 2 2 45 488 Q Q Q Q 4 spa Jacuzzi Europe Q Jacuzzi EcoHeat CoolPower 11a 11b 11c spa spa...

Page 42: ...5 Q spa 3 spa Q spa pak Performance Jacuzzi 9 spa pak 4 spa spa pak spa pak spa 1 spa pak Q 10a 10b 10c C Q Q spa Q Jacuzzi EcoHeat CoolPower 11a 11b 11c 10 EN1717 AA AB AD IEC 60335 1 600 a 6 35 a 0...

Page 43: ...N VS2 220 240 1 2 380 415 2N 3 380 415 3N Q 220 240 Q 220 240 Q H 05 VV F 220 240 V min 4 mm2 380 415 V min 2 5 mm2 Q spa pak Performance spa pak Q 220 240 16A Q 220 240 4 2 8a 8b 8c B B1 Q Jacuzzi Ec...

Page 44: ...44 spa Spa Jacuzzi EN 60335 2 60 EN 61000 EN 55014 Q Q Spa Jacuzzi 1 0 03 A TE T Q III Q spa spa Q EN 60335 2 60 8a 8b 8c part e Q EN 62471...

Page 45: ...45...

Page 46: ...46...

Page 47: ...47...

Page 48: ...as modificaciones que considere oportunas sin obligaci n de preaviso o de sustituci n Jacuzzi Europe S p A JACUZZI EUROPE S p A S S Pontebbana km 97 200 33098 Valvasone Arzene PN ITALIA Tel 39 0434 85...

Reviews: