background image

ENGLISH

21

Jacuzzi Whirlpool Bath   K339000X   3/06

Electronic Control Panel Operation 

(with optional Chromotherapy/Illumatherapy

TM

 lighting)

All tubs in this product line come with electronic controls and standard Chromotherapy or Illumatherapy

TM

.  Read and follow the

operation instructions for the control system of your unit.

General Functions

This Jacuzzi tub is equipped with a seven button electronic control panel.  The seven button panel controls a two speed pump/
motor, Chromotherapy or Illumatherapy

TM

 lighting, air controls, and wave control.  LED lights (in the control panel) indicate function

levels.  When switching between functions, the LED for the inactive functions will dim and the active function will brighten.

The bath is equipped with a water level sensor(s).  When the water level is 

below

 the sensor, the pump/motor can 

not

 be

activated.  If the ON/OFF pump/motor button is pressed at this time, the pump/motor will not operate.  When the water goes
above the water level sensor, the pump/motor can be activated.  If the water level drops below the level sensor, the pump/motor
will shut 

OFF

.  To restart the pump/motor after the water level goes above the level sensor, the ON/OFF pump/motor button must

be pressed.  The pump/motor will automatically shut off 30 minutes after the pump/motor was turned on.

NOTE: 

Ensure the water level sensor located inside the bath is free of any soap or dirt buildup.

Bath Light 

Right Air Valve 

Left Air Valve 

Left Air Valve 
Status LED 

Right Air Valve 
Status LED 

Pump/Motor 
Status LED 

ON/OFF 

Pump/Motor 

Wave Function 

Toggle Buttons

OPERATING INSTRUCTIONS (cont'd)

Normal Operation 

(with the bath filled to the proper level)

Pump/Motor Switch 

(ON/OFF )

Pressing the 

 button will turn ON the two speed pump/

motor at HIGH speed.  Pressing a second time will turn OFF
the pump/motor. To change speeds use the Toggle buttons.

Pump/Motor Status LED

 When the pump/motor is ON at HIGH speed all four LED

indicator lights will be lit.  When the pump/motor is ON at
LOW speed the bottom LED indicator light will be lit.

Left Air Valve Switch

Pressing this 

 button will acitvate the left air valves use

the Toggle buttons to increase/decrease air flow to the left set
of jets.  The air flow can be adjusted from no air to maximum
air.

Left Air Valve Status LED

 The Left Air Valve Status LED will show four LED lights at

maximum air and only one LED light when the air is turned
OFF.  Each additional LED indicates more air flow.

Right Air Valve Switch

Pressing this 

 button will acitvate the right air valves. Use

the Toggle buttons to increase/decrease air flow to the right
set of jets.  The air flow can be adjusted from no air to maxi-
mum air.

Right Air Valve Status LED

The Right Air Valve Status LED will show four LED lights at

maximum air and only one LED light when the air is turned
OFF.  Each additional LED indicates more air flow.

Bath Light Switch 

(ON/OFF )

Pressing this 

 button will turn ON the white bath light(s).

Pressing the Toggle buttons at this time will increase or de-
crease light intensity.  Pressing the  button a second time will
access the saved favorite color.  To cycle lighting colors use
the Toggle button. Pressing the Toggle button again will stop
the light cycling.  The color displayed when the cycle has been
stopped will be saved as your favorite color.  Pressing the
button a third time to turn OFF the light.

NOTE: When switching between functions, the LED for
the inactive functions will dim and the active function will
brighten.

Wave Function Switch 

(ON/OFF )

Pressing this 

 button activates wave action by opening

and closing both right and left air valves. Pressing a second
time will turn OFF the wave action.

Toggle Buttons

The Toggle buttons, up 

 and down 

, act on each of the

other buttons to increase, decrease, or modify functionality.
Use the up arrow to increase and the down arrow to decrease.

• Pressing a toggle button after pressing the Pump/Motor
button will increase or decrease speeds on the Pump/Mo-
tor. If the pump/motor is on HIGH speed press the down
arrow to select LOW speed.  If the pump/motor is on LOW
speed press the up arrow to select HIGH speed.

• Pressing an up or down toggle button after pressing the
Bath Light button once will increase or decrease the white
light brightness.  Pressing an up or down toggle button
after pressing the Bath Light button twice will begin cycling
the light colors.  Leave the colors cycling or press the same
toggle button again to stop the color cycling.  With the lights
stopped on a color pressing the Bath Light button a third
time will turn OFF the light. (A favorite color will be saved
ONLY when the cycling has been stopped on that color
and then turned OFF.)

Summary of Contents for Luxury/Designer Bath Series K339000X

Page 1: ...uct registration card provided with your unit Write and save the model and serial number of your unit below Date Purchased ____________________________________________________________ Purchased From _...

Page 2: ...N ELECTRIC SHOCK DO NOT USE THIS HYDROMASSAGE BATHTUB DISCONNECT THE HYDROMASSAGE BATHTUB AND HAVE THE PROBLEM CORRECTED BY A QUALIFIED SERVICE REPRESENTATIVE BEFORE USING WARNING FOR PERMANENTLY CONN...

Page 3: ...BY THE MANUFACTURERS WARNING TOAVOIDINJURY EXERCISECAUTIONWHENENTERINGOREXITINGTHEHYDROMASSAGEBATHTUB WARNING KEEP BODY AND HAIR A MINIMUM OF 6 15 2 cm AWAY FROM SUCTION FITTING AT ALL TIMES WHEN THE...

Page 4: ...______ 19 Clean Up After Installation _______________________________________________________________ 19 Operating Instructions __________________________________________________________________ 20 22...

Page 5: ...he carrier For definitions of warranty coverage and limitations refer to the published warranty information packed with the product All bath units are factory tested for proper operation and watertigh...

Page 6: ...ed P N P187000 16 1 4 413 mm A 13 1 2 343 mm B Factory Installed Intake S749000 Heater Factory Installed Intake S749000 Heater Factory Installed Intake S749000 Heater Factory Installed Intake S749000...

Page 7: ...otected separate circuit SPECIFICATIONS DUETTA 7242 RH 72 1829 mm L 42 1067 mm W 26 660 mm H Template Provided P N DA06000 Not Available Factory Installed Intake S749000 Heater Min 98 U S gal 371 lite...

Page 8: ...are nominal with a tolerance of 0 and 1 4 6 4 mm W H BELLAVISTA CORNER Right Hand SIDE VIEW END VIEW 2 51 mm Heater MAX 1 2 FOR ALL UNITS Electrical Service Requirements All require a dedicated GFCI p...

Page 9: ...Access Opt Service Access BELLAVISTA 5 5 Right Hand 4 x 4 42 72 10 1 2 35 13 16 11 3 4 6 30 1 8 Heater Motor 12 H x 18 L Service Access Opt Service Access BELLAVISTA 6 Right Hand CIPREA Right Hand 4...

Page 10: ...4 mm 10 Jacuzzi Whirlpool Bath K339000X 3 06 ROUGHING IN REFERENCE ELARA 6042 Right Hand 60 42 21 4 2 10 6 12 x 4 2 Heater Motor Opt Service Access 12 H x 18 L Service Access ELARA 6636 Right Hand 66...

Page 11: ...REFERENCE RECTANGULAR Some tubs are supplied with cutout and or undermount template Refer to CUTOUT on pages 6 8 for template part numbers Add 1 4 to this dimension when roughing in for 3 wall niche N...

Page 12: ...1 4 6 4 mm ROUGHING IN REFERENCE VENICIA Right Hand 10 1 2 36 3 42 72 12 1 8 5 1 4 29 7 8 18 x 4 Motor 12 H x 18 L Service Access Heater Opt Service Access 12 H x 18 L Service Access Opt Service Acce...

Page 13: ...ments are in inches To convert to millimeters multiply inches by 25 4 3 Service access dimensions given are minimum size 4 The overall dimensions are nominal with a tolerance of 0 and 1 4 6 4 mm 60 60...

Page 14: ...anchoring material is NOT used use construction adhesive under the foam feet and fasten the metal anchor straps to the floor to prevent the unit from shifting while trim deck finishes or finish caulk...

Page 15: ...THOUT SKIRT 12 12 FRONT HEATER Service Access Corner Tubs For partially or fully sunken installations allow for ac cess to service connections It is the installer s respon sibility to provide sufficie...

Page 16: ...e enough space to maneuver and insert tub The Designer Luxury line whirlpool tubs have electrical plumbing and lighting systems installed Do not lift the bath by the plumbing or wiring at any time han...

Page 17: ...in the bottom illustration Do not use plumbing fixtures or plumbing lines to lower unit The clearance under the substrate is required for air flow circulation requirements Place a piece of scrap lumbe...

Page 18: ...nfirm you have 120 VAC 20 AMP and 15 AMP service requirements The GFCI circuits must match these requirements Care must be taken to connect the 20 AMP pump motor or control box power cord ONLY to the...

Page 19: ...ontrol the direction of the spray NOTE Proper installation of a shower is the responsibil ity of the installer Jacuzzi Whirlpool Bath is not respon sible for damage to the unit or for water damage whi...

Page 20: ...ly Baths equipped with 2 speed motors and electronic controls can also influence water force and force of air Direction To change the direction of the water flow swivel the jet nozzle to the desired a...

Page 21: ...om no air to maximum air Left Air Valve Status LED The Left Air Valve Status LED will show four LED lights at maximum air and only one LED light when the air is turned OFF Each additional LED indicate...

Page 22: ...through the whirlpool system High Limit Switch The heater includes an exclusive High Limit switch This safety circuit will not false trip from hot tap water It will only turn off the heater if the th...

Page 23: ...er and run for 2 to 3 minutes Drain completely and rinse off any residue Remember to reset the air valves to your bathing comfort level DANGER Harmful if swallowed Eye irritant Protect your eyes skin...

Page 24: ...st always be in place on the suction fitting to minimize the potential hazard of hair and or body en trapment NOTCH GASKET COVER STRAINER SCREW SUCTION FITTING SUCTION COVER STRAINER ASSEMBLY Lighting...

Page 25: ...junction box With motor turned off remove safety cover and remove any debris Clean thoroughly before replacing Replace suction cover before operating Use electronic controls to open air valves Reset...

Page 26: ...2008 by Jacuzzi Whirlpool Bath Products Page of 2 Publication GR86000A 08 08 8 Button Control Panel SPECIFICATIONS FOR ALL UNITS Electrical Service Requirements Requires a separate dedicated GFCI prot...

Page 27: ...rom the left side to the right side next to the pump motor The following details will replace information found in the Combination Air Bath and Whirlpool Installation and Operation Instructions BR2800...