Standard Filtration Modes FØ - F3 (EPROM Rev. 3.56)
Heating in either of these modes (FØ - F3) is automatically controlled by the water temperature. If the hot tub
water drops 2ºF (1.2ºC) below the temperature setpoint, the heater will turn on with the 24-hour circulation
pump. Both remain on until the water temperature rises to the temperature setpoint, then the heater will turn off.
Refer to the options below:
FØ
No filter cycles, 5 minute blowout cycle once a day, every 24 hours from the time of power up.
F1
1 hour of filtration a day (1/2 hour cycle every 12 hours)
F2
1 1/2 hours of filtration a day (1/2 hour cycle every 8 hours)
F3
2 hours of filtration a day (1/2 hour cycle every 6 hours)
Economy Filtration Modes F4 - F6 (EPROM Rev. 3.56)
In any economy mode (F4 - F6), the control panel’s digital timer circuit determines when each filter cycle takes
place. The heater will only operate while a filter cycle is running. The heater will not operate when either Jets
button is pressed to manually cancel an active filter cycle or to activate the main jet pump between filter cycles.
Refer to the options below:
F4
1 hour of filtration a day (1/2 hour cycle every 12 hours)
F5
1 1/2 hours of filtration a day (1/2 hour cycle every 8 hours)
F6
2 hours of filtration a day (1/2 hour cycle every 6 hours)
Lockout Modes L1 - L2 (EPROM Rev. 3.56)
Additional modes (L1 - L2) are special modes designed for servicing/cleaning. Refer to the options below:
L1
Lock Out (disables all hot tub functions to permit filter cleaning or other maintenance) - If the hot tub is
heating when the system is put into lockout mode, the heater will immediately shut off and the circulation
pump will cycle water for 30 seconds to cool the heater element, then shut off.
L2
Lock Mode (disables the jets and light buttons to prevent unauthorized use of the hot tub) - The filter cycles
and heater will continue to operate as programmed in this mode.
Example: The “F3” filter cycle was enabled
prior to choosing the lock mode. The hot tub continues to perform filter cycle “F3” until lock mode is cancelled,
allowing another filter cycle to be selected.
The temperature display flashes when either Lock Out Mode is enabled.