23
5.5 Lock Out Mode
The control panel temperature display flashes when the Lock Out Mode is active. Lock Out
Mode disables all hot tub functions to permit filter cleaning. If the hot tub is heating when
lockout mode is selected, the heater will immediately turn off and the circulation pump will
cycle water for 30 seconds to cool the heater element, then turn off.
See section 4.2 (page
20).
5.6 Summer Logic
When the water temperature in the hot tub rises 2ºF (1ºC) above the set temperature setpoint.
The hot tub goes into “Summer Logic.” When this happens, the circulation pump automati-
cally turns off to prevent additional heat build up from the pump that would eventually cre-
ate an overheat condition. The circulation pump, main pump and aftermarket ozone (when
installed) will remain off until the water temperature cools to the set temperature, then reac-
tivate as programmed.
This setting is not user-programmable.
Note: Summer Logic does not take effect until the hot tub’s water reaches 95ºF (35ºC) or higher.
6.0 Understanding Circuit Board Pin Assignments
6.1 Circuit Board Jumpers
Refer to the jumper pin table and circuit board diagram below for specific details:
WHT
J2
J3
Transformer
120 VAC
J4
J20
J21
J12
J14
J16
J11
J15
J13
J17
J7
J8
J9
J10
J5
J6
Heater IN
Heater OUT
F1*
K1
K2
K3
K4
K5
K7
K8
1
2
3
4
5
6
JP1
7
8
1
2
3
4
5
6
JP1
7
8
N
J 1
TE
M
P/H
I-L
IM
IT
FL
O
W
SW
1
2
3
4
5
6
JP1
7
8
J 4
N
N
N
N
N
N
N
L
L
L
L
L
L
L
L
L
Spa Light
Ozone
Circ Pump
Pump 1
Pump 2
Red Black
Heater In
Heater Out
F1
Rev. 3.53
Display is
Flashing
Display is
Flashing
Circuit Board Jumpers
Pins Jumpers
J-315 Board Only
J-325, J-335 & J345 Board
1-2:
OFF
Enables 40A Logic. Heater will opereate with
high speed pump 1 on.
Enables 50A Logic; Allows heater to run with
1 pump in high speed.
Default Setting.
1-2:
ON
Enables 15A Logic
Default Setting.
(120V Operation), or 30A Optional(240V
Operation).
Enables 40A logic; Forces heater off when
any jet pumps are on high speed.
Overrides
50A or 60A Logic.
3-4:
OFF
Not used on J-315.
Enables 1 Pump Logic. (J-325 Only)
3-4:
ON
Not used on J-315.
Enables 2 Pump Logic.
5-6:
OFF
Not used on J-315.
Leave off for 40A or 50A Logic.
5-6:
ON
Not used on J-315.
Enables 60A Logic. (Not used on J-325)
7-8:
OFF
Enables Fahrenheit (ºF) temperature display.
7-8:
ON
Enables Celsius (ºC) temperature display.
J-315 Cir
cuit Board
J-325, J235 & J-345
Cir
cuit Board
6600-286
6600-289
Summary of Contents for Premium J-315
Page 45: ...45 Appendix...
Page 62: ...62 Notes...