51
A10 2006 LED Series J-325 / J-335 / J-345 Board (USA/Canada 60 Hz)
USA/Canada 60 Hz Models
•
Board Type: #6600-288
•
Compatible Models: Original equipment board for all
2006+ domestic J-325, J-335 and J-345 models with1 or
2-pumps.
TRANSFORMER
SP
A LIGHT
O
3
optional CD Ozone
Cir
c.
Pump
N
L
N
L
N
N
N
N
L
L1
L2
N
L
N
L
L
L
L
L
PUMP 1
PUMP 2
LO
HI
HI
GRN
US / Canada 60 Hz Power Connections
240 V
AC 60 Hz, 1-Phase;
USE COPPER CONDUCTORS ONL
Y, WIRE SIZE MUST BE
APPROPRIA
TE PER NEC AND/OR LOCAL CODES
*
This device complies with Part
15 of the FCC rules. Operation is
subject to the following two
conditions:
1.
This device may not cause
harmful interfer
ence.
2.
This device must accept any
intefer
ence r
eceived including
interfer
ence that may cause
undesir
ed operation.
STEREO
*
(optional)
20A, 250 V
, SC-20
Temp. Sensor
HI-Limit/Fr
eeze Sensor
Flow Switch
Heater
5.5 kW
JP1
4
2
3
1
6
5
8
7
Logic Jumper Settings for all Domestic 60 Hz Models:
JP1 1-2 ON = 40 A Logic (Overrides 60A Logic)
JP1 1-2 OFF = 50 A Logic
JP1 5-6 ON = 60 A Logic (J-345 w/3.56 Chip Only)
JP1 5-6 OFF = 40 or 50A Logic (3.56 Chip Only)
JP1 7-8 ON = C T
emperatur
e Display
JP1 7-8 OFF = F T
emperatur
e Display
1
2
3
4
5
6
7
10
1
1
12
13
14
15
16
17
18
19
20
21
22
e= equipment access side
J-345
e
J-335
e
J-325