24
Maintenance of minimum temperature of water in tub and
anti-freeze protection of the pipes (“Smart Winter”).
The system software of your Profile spa is designed to pro-
vide efficient, rational management of any hazardous situations
which may occur due to excessively cold temperatures and freez-
ing of the water.
For further information on water heating and system safe-
guards, refer to the product's installation manual.
NOTE:
when the anti-freeze protection is active, the display will
show the message
ICE
.
ABNORMAL OPERATING CONDITIONS
ALARM SIGNALS
If there is an alarm, this is indicated on the display, with the cor-
responding code.
You will continue to see the code if the alarm condition persists.
Here is a list of the various alarms that may appear. Refer to the
product's installation manual for a detailed description of the var-
ious messages that may appear on the display.
“
FLC
”
In some models, the initials “FLC” may appear on the display.
- Contact an authorized Jacuzzi
®
service centre.
“
FLO
” (flashing)
The heater is not turned on.
- The system attempts to reactivate the heater three times.
“
FLO
” (stable)
The heater cannot be turned on.
Try turning the switch up the line from the spa off and back on; if
the signal stays on, contact an authorized Jacuzzi
®
service centre.
“
HOH
”
The measured temperature at the heater is 48 °C
(118 °F) or higher.
DO NOT ENTER THE WATER
- If the alarm condition persists, even though the temperature has
dropped back below 44°C, try turning the switch up the line from
the spa off and back on. If the signal stays on, contact an author-
ized Jacuzzi
®
service centre.
“
Ho
”
Excessive water temperature.
DO NOT ENTER THE WATER
-
If present, remove cover from spa.
- If the excessive temperature increase is due to sunlight, add cold
water to the spa.
When the temperature has dropped to below 43 °C (109 °F), the
spa should re-activate automatically. If it does not, disconnect the
power supply and contact an
authorized Jacuzzi
®
service centre.
“
rPF
”
Defective temperature probe
DO NOT ENTER THE WATER
It is not possible to activate any function.
- Contact an authorized Jacuzzi
®
service centre.
“
HPF
”
Activation of safety thermostat (electric heater can-
not be turned on).
- Try turning the switch up the line from the spa off and back on
(system reset). If the signal stays on, contact an authorized Jacuzzi
®
service centre.
“
cErr
”
The system has been locked.
- Make sure that you have not left the compensation tank drain open.
- Try turning the switch up the line from the spa off and back on
(system reset). If the signal stays on, contact an authorized Jacuzzi
®
service centre.
Summary of Contents for Profile
Page 2: ......
Page 61: ...61 JACUZZI SPA SPA Salus Per Aquam Spa Jacuzzi Profile 90...
Page 62: ...62 Jacuzzi Europe S p A Jacuzzi Jacuzzi Europe S p A 40 C 38 C 40 C 35 36 C 38 C 10 15...
Page 63: ...MaxiJa cuzzi 40 spa spa Clearray 63...
Page 70: ...TUNER F M 10 Bluetooth Bluetooth spa MP3 Bluetooth VOL VOL VOL VOL VOL VOL 70...
Page 71: ...OPEN CR2032 CLOSE spa 4 71 CR2032 3V OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE...