background image

 

www.jacuzzi.com

 

Page 5

Experience

English

Pure Air® Auto-Dri™ Air Channels

To remove accumulations of bathtub residue from the whirlpool system, it is recommended that a Whirlpool bathtub be 

cleaned at least twice a month. For best results, however, we recommend that you clean your Whirlpool bathtub after 

each use using Systems Clean™, our exclusive two-part plumbing system cleaner made specifically for Whirlpool bath

-

tubs. Systems Clean™ is available through an authorized Jacuzzi Luxury Bath distributor, by calling 1-800-288-4002 or 

may be purchased online at www.jacuzzi.com.

  J2 Auto-Dri™ Air Channels

The blower will operate for 20 minutes and then automatically shut off, unless power is manually turned off. In either 

 

case, 20 minutes after the blower has shut off, it will turn ON for a one-minute drying cycle to blow out any water remain

-

ing in the air system.

If the bath is used without the blower operating (showering or bathing without using the Pure Air® system), initiate the 

one-minute drying cycle manually by use of the ON/OFF switch. Turn the switch ON and OFF again as you exit the bath 

and the drying cycle will occur in 20 minutes.

  J2 Daily Auto-Dri™ Cycle

To Activate: Holding the 

 button for five-seconds when the blower is off activates the daily Auto-Dri™ cycle. The blower 

will start every day at the same time for one-minute. Once the daily Auto-Dri™ cycle is activated, the blower will come on 

for one-second, turn off for two-seconds, come on for one-second and then turn off.

To Deactivate: Holding the 

 button for five-seconds when the blower is off deactivates the daily Auto-Dri™ cycle. When 

the daily Auto-Dri™ cycle is deactivated, the blower will come on for one-second and then turn off.

  J4 Auto-Dri™ Air Channels

The Auto-Dri™cycle is automatic and will reduce excessive accumulation of residual water in the air channels.

There are two Auto-Dri™ cycles: drain assisted Auto-Dri™ cycle and daily Auto-Dri™ cycle.

  J4 Drain Assist

The Auto-Dri™ cycle is sensor assisted – two sensors (metal dials) are located near the drain of the bathtub. The sensors 

detect the presence and absence of water in the bathtub.

 To ensure effective and correct operation of the water sensors, it is important to keep them clean and free from block

-

age or objects.

After bathing and following the emptying of the bathing well, the sensors detect a “no water” condition. A five minute wait 

time elapses and then the blower is activated. The blower will cycle through a range of speeds for 2 ½ minutes, during 

which either 2 or 3 indicator lights will flash at various speeds.

• 

The Auto-Dri™ cycle will engage even if the blower is not used during bathing.

• 

The cycle may initiate more than once if the sensors become wet during any part of the Auto-Dri™ operation or during 

routine cleaning of the bathtub. This is normal and does not require attention.

  J4 Daily Auto-Dri™ Cycle

Each day, the blower will automatically activate a daily Auto-Dri™ cycle. The blower will operate for one minute on high 

power, followed by 15 seconds at ½ power.

To set Auto-Dri™ cycle time:

 Wait until the time, which you desire the daily Auto-Dri™ cycle to activate, with the blower off, 

press and hold the plus button for five seconds. To confirm that you have set the time, the blower will cycle between on 

and off 2 times in a 4 second span.

To cancel daily Auto-Dri™ cycle:

 With the blower off, press and hold the plus button for five seconds. To confirm that you 

have cancelled the Auto-Dri™ cycle , the blower will come on for 1 second and then stop.

  You must set the daily Auto-Dri™ cycle upon installation; the default is no pre-set daily Auto-Dri™ cycle.

  If a power failure occurs, the system will default to no daily Auto-Dri™ cycle.

Summary of Contents for Pure Air Series

Page 1: ...EXPERIENCE MANUAL Jacuzzi Luxury Bath 14525 Monte Vista Avenue Chino CA 91710 1 800 288 4002 www jacuzzi com Pure Air Whirlpool Salon Spa LG34000B 10 2015 ...

Page 2: ... is a health precaution as these bathtubs are not designed to hold water continuously like pools or spas Close the drain and fill the bathtub until water is at least 1 to 2 25 mm to 51 mm above the highest jet or air inlet see water line indicated in the illustration Figure 1 Do not turn on the Whirlpool or Pure Air system at any time if the jets or air inlets are not completely immersed in water ...

Page 3: ...ions disconnect all power supply cables to both 120 VAC services J2 Control Panel Pure Air Schematic Diagram J4 Control Panel Pure Air Schematic Diagram Fig 2 CONTROL PANEL BLOWER 120 VAC 15A Dedicated GFCI Circuit Required G Fig 3 BLOWER CONTROL PANEL CHROMATHERAPY LIGHTS 2X Auto Dri SENSOR CABLE LIGHT CONTROL BOX 120 VAC Panel LED Light 120VAC 15A Dedicated GFCI Circuit Required 120VAC 15A Dedic...

Page 4: ... active function will brighten Fig 5 BLOWER OPERATION Press to turn ON Press again to turn OFF Use toggles to control speed INCREASE TOGGLE Press to increase the selected feature Press and hold 5 seconds to cancel daily Auto Dri To select a solid color press the increase toggle when the color is displayed DECREASE TOGGLE Press to decrease the selected feature CHROMATHERAPY Press once to turn ON co...

Page 5: ...uto Dri cycle is automatic and will reduce excessive accumulation of residual water in the air channels There are two Auto Dri cycles drain assisted Auto Dri cycle and daily Auto Dri cycle J4 Drain Assist The Auto Dri cycle is sensor assisted two sensors metal dials are located near the drain of the bathtub The sensors detect the presence and absence of water in the bathtub To ensure effective and...

Page 6: ...C 15A Dedicated GFCI Circuit Required G G J2 Control Panel Whirlpool Schematic Diagram CONTROL PANEL 120VAC PUMP PUMP MOTOR CONTROL BOX 120V 20A Decidated GFCI Circuit Breaker 120V 15A Decidated GFCI Circuit Breaker FOR MODELS WITH IN LINE HEATER G CHROMATHERAPY LIGHTS Reference Illustration for a Whirlpool System Fig 6 J2 Control Panel Whirlpool with Chromatherapy Schematic Diagram Fig 7 ...

Page 7: ...once to activate color lighting Press a second time to activate solid White color Press a third time to turn OFF NOTE The Up and Down buttons can be used to select colors or intensity Press button to activate the color blending feature Light sequence is as follows Blue Teal Green Yellow Or ange Red Pink Purple To select a solid color press the Up button when the color is displayed Solid White colo...

Page 8: ... select a solid color press increase toggle when color is displayed DECREASE TOGGLE Press to decrease the selected feature LEFT AIR VALVE CONTROL Press to activate the left air valve Use toggles to control air mix RIGHT AIR VALVE CONTROL Press to activate the right air valve Use toggles to control air mix WAVE FEATURE Press to turn ON Press again to turn OFF CHROMATHERAPY Press once to turn ON col...

Page 9: ...a visible indicator light on the heater itself that signifies the heater is operating The heater will help maintain the temperature of the water in the bathtub It is not intended to heat the water to a desired temperature Vacuum Switch The heater is equipped with a preset vacuum switch which will not allow the heater to turn ON if the pump is not running and water is not flowing through the whirlp...

Page 10: ...e purchased online at www jacuzzi com To clean your bathtub simply use a mild non abrasive liquid detergent solution You can protect and restore the gloss to a dulled acrylic surface by applying Meguiar s 10 Mirror Glaze a product specifically designed for use on acrylic finishes If Meguiar s is not available use a fine grade automotive rubbing compound followed by an application of clear automoti...

Page 11: ...UMP MOTOR 120VAC 20A Dedicated GFCI Required FUSE FUSE FUSE FUSE BLOWER HEATER FUSE JUNCTION BOX AUTO DRI SENSOR CABLES Fig 17 CHROMATHERAPY LIGHTS 2X 1 2 3 4 VIEW A SEE VIEW A PUMP MOTOR ILLUMATHERAPY LIGHTS 4X FUSE FUSE FUSE FUSE BLOWER HEATER CONTROL BOX Air Valve 240VAC Pump RS232 Panel Blower Inside Light 1 Inside Light 3 Ambient Light 1 Temp Sensor Inside Light 2 Inside Light 4 LOGO Light Am...

Page 12: ...selected feature LEFT AIR VALVE CONTROL Press to activate the left air valve Use toggles to control air mix RIGHT AIR VALVE CONTROL Press to activate the right air valve Use toggles to control air mix WAVE FEATURE Press either Whirlpool or Pure Air feature Press to turn ON wave Press again to turn OFF wave CHROMATHERAPY OR ILLUMATHERAPY Press once to turn ON colored lighting Toggles will cycle col...

Page 13: ...uzzi Luxury Bath 800 288 4002 Blower operates but NO air is exiting the holes Check valves are stuck in the closed position Contact Jacuzzi Luxury Bath 800 288 4002 Blower operates but air is not exiting all of the holes Blower intensity is not sufficient Obstructed air holes Increase the blower intensity NOTE The system is designed such that all air channels operate at the 4th blower setting Remo...

Page 14: ...____________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________...

Reviews: