background image

 

www.jacuzzi.com

 

Page 9

Experience

English

Whirlpool Operations (Continued)

  Controlling Whirlpool Direction & Flow

 

CAUTION:

 Never run the whirlpool system with all the jets closed.

To adjust the direction of the jets:

• 

To change the direction of the water flow, swivel the jet nozzle to the desired angle, Figure 12.

To adjust the water flow to the jets:

• 

Increase the force of the flow by rotating the nozzle or jet face to the left (counterclockwise). Decrease the force of the 

flow by rotating the nozzle or jet face to the right (clockwise). Reference Figure 13.

RapidHeat™

  RapidHeat™ (Standard on Salon® models)

The heater turns ON automatically any time whirlpool operation is active. Heater 

 

operation is not displayed on the control panel. There is a visible indicator light on the 

heater itself that signifies the heater is operating. The heater will help maintain the 

temperature of the water in the bathtub. It is not intended to heat the water to a desired 

temperature.

  Vacuum Switch

The heater is equipped with a preset vacuum switch which will not allow 

the heater to turn ON if the pump is not running and water is not flowing 

through the whirlpool system.

  High-Limit Switch

The heater includes an exclusive High-Limit switch. This safety circuit will not false trip from hot tap water. It will only turn 

OFF the heater if the thermostat fails. To reset, press the button. If the high-limit trips frequently, please contact us at 

www.jacuzzi.com, or at 1-800-288-4002.

Fig. 12

Fig. 13

PUSH  TO RESET

OVER HEAT

PROTECTION

HEATER ON

High Limit 

Reset

Heater 

On

Fig. 14

 IMPORTANT NOTE: 

Heater will only work when 

the water temp is 77°F or 

above. You should always fill 

the tub with warm water. 

Summary of Contents for Pure Air Series

Page 1: ...EXPERIENCE MANUAL Jacuzzi Luxury Bath 14525 Monte Vista Avenue Chino CA 91710 1 800 288 4002 www jacuzzi com Pure Air Whirlpool Salon Spa LG34000B 10 2015 ...

Page 2: ... is a health precaution as these bathtubs are not designed to hold water continuously like pools or spas Close the drain and fill the bathtub until water is at least 1 to 2 25 mm to 51 mm above the highest jet or air inlet see water line indicated in the illustration Figure 1 Do not turn on the Whirlpool or Pure Air system at any time if the jets or air inlets are not completely immersed in water ...

Page 3: ...ions disconnect all power supply cables to both 120 VAC services J2 Control Panel Pure Air Schematic Diagram J4 Control Panel Pure Air Schematic Diagram Fig 2 CONTROL PANEL BLOWER 120 VAC 15A Dedicated GFCI Circuit Required G Fig 3 BLOWER CONTROL PANEL CHROMATHERAPY LIGHTS 2X Auto Dri SENSOR CABLE LIGHT CONTROL BOX 120 VAC Panel LED Light 120VAC 15A Dedicated GFCI Circuit Required 120VAC 15A Dedic...

Page 4: ... active function will brighten Fig 5 BLOWER OPERATION Press to turn ON Press again to turn OFF Use toggles to control speed INCREASE TOGGLE Press to increase the selected feature Press and hold 5 seconds to cancel daily Auto Dri To select a solid color press the increase toggle when the color is displayed DECREASE TOGGLE Press to decrease the selected feature CHROMATHERAPY Press once to turn ON co...

Page 5: ...uto Dri cycle is automatic and will reduce excessive accumulation of residual water in the air channels There are two Auto Dri cycles drain assisted Auto Dri cycle and daily Auto Dri cycle J4 Drain Assist The Auto Dri cycle is sensor assisted two sensors metal dials are located near the drain of the bathtub The sensors detect the presence and absence of water in the bathtub To ensure effective and...

Page 6: ...C 15A Dedicated GFCI Circuit Required G G J2 Control Panel Whirlpool Schematic Diagram CONTROL PANEL 120VAC PUMP PUMP MOTOR CONTROL BOX 120V 20A Decidated GFCI Circuit Breaker 120V 15A Decidated GFCI Circuit Breaker FOR MODELS WITH IN LINE HEATER G CHROMATHERAPY LIGHTS Reference Illustration for a Whirlpool System Fig 6 J2 Control Panel Whirlpool with Chromatherapy Schematic Diagram Fig 7 ...

Page 7: ...once to activate color lighting Press a second time to activate solid White color Press a third time to turn OFF NOTE The Up and Down buttons can be used to select colors or intensity Press button to activate the color blending feature Light sequence is as follows Blue Teal Green Yellow Or ange Red Pink Purple To select a solid color press the Up button when the color is displayed Solid White colo...

Page 8: ... select a solid color press increase toggle when color is displayed DECREASE TOGGLE Press to decrease the selected feature LEFT AIR VALVE CONTROL Press to activate the left air valve Use toggles to control air mix RIGHT AIR VALVE CONTROL Press to activate the right air valve Use toggles to control air mix WAVE FEATURE Press to turn ON Press again to turn OFF CHROMATHERAPY Press once to turn ON col...

Page 9: ...a visible indicator light on the heater itself that signifies the heater is operating The heater will help maintain the temperature of the water in the bathtub It is not intended to heat the water to a desired temperature Vacuum Switch The heater is equipped with a preset vacuum switch which will not allow the heater to turn ON if the pump is not running and water is not flowing through the whirlp...

Page 10: ...e purchased online at www jacuzzi com To clean your bathtub simply use a mild non abrasive liquid detergent solution You can protect and restore the gloss to a dulled acrylic surface by applying Meguiar s 10 Mirror Glaze a product specifically designed for use on acrylic finishes If Meguiar s is not available use a fine grade automotive rubbing compound followed by an application of clear automoti...

Page 11: ...UMP MOTOR 120VAC 20A Dedicated GFCI Required FUSE FUSE FUSE FUSE BLOWER HEATER FUSE JUNCTION BOX AUTO DRI SENSOR CABLES Fig 17 CHROMATHERAPY LIGHTS 2X 1 2 3 4 VIEW A SEE VIEW A PUMP MOTOR ILLUMATHERAPY LIGHTS 4X FUSE FUSE FUSE FUSE BLOWER HEATER CONTROL BOX Air Valve 240VAC Pump RS232 Panel Blower Inside Light 1 Inside Light 3 Ambient Light 1 Temp Sensor Inside Light 2 Inside Light 4 LOGO Light Am...

Page 12: ...selected feature LEFT AIR VALVE CONTROL Press to activate the left air valve Use toggles to control air mix RIGHT AIR VALVE CONTROL Press to activate the right air valve Use toggles to control air mix WAVE FEATURE Press either Whirlpool or Pure Air feature Press to turn ON wave Press again to turn OFF wave CHROMATHERAPY OR ILLUMATHERAPY Press once to turn ON colored lighting Toggles will cycle col...

Page 13: ...uzzi Luxury Bath 800 288 4002 Blower operates but NO air is exiting the holes Check valves are stuck in the closed position Contact Jacuzzi Luxury Bath 800 288 4002 Blower operates but air is not exiting all of the holes Blower intensity is not sufficient Obstructed air holes Increase the blower intensity NOTE The system is designed such that all air channels operate at the 4th blower setting Remo...

Page 14: ...____________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________...