background image

14

Summary of Contents for S198

Page 1: ...Affinity Owner s Manual...

Page 2: ...AND ADJUST WATER TEMPERATURE BEFORE USE WARNING RISKOFHYPERTHERMIA PEOPLEUSINGMEDICATIONSAND ORHAVINGANADVERSEMEDICALHISTORY SHOULD CONSULT A PHYSICIAN BEFORE USING A HYRDOMASSAGE BATHTUB EQUIPPED WI...

Page 3: ..._____________________________ 7 Water Supply________________________________________________________________________ 7 Operation _______________________________________________________________________...

Page 4: ...RICAL REQUIREMENTS BATH 115 VAC 60 Hz 30 Amp Single Phase Must be Class A GFCI Protected The unit must be hard wired permanent from this circuit to the control box ELECTRICAL REQUIREMENTS RAPIDHEAT HE...

Page 5: ...uld not be removed until final cleanup Important Read complete instructions before beginning installation Each whirlpool bath arrives ready for installation completely equipped with motor pump assembl...

Page 6: ...CD Radio ground ing wire CD Radio chassis to control box bonding bar coiled under the bath rim Run wires through wall cutout to CD Radio build out 38 9 MIN BATH PERIMETER 1x4 NOT FOR SUPPORT FINISHED...

Page 7: ...s for future use Run wires through sleeve Insert sleeve into build out When flush bend appropriate tabs to hold sleeve firmly in place Connect the speaker power connector and TV audio to the CD radio...

Page 8: ...eaker wires to back cover speakers observing polarity right speaker purple and purple w black stripe left speaker green and green w black stripe Then position back cover by sliding downward over gaske...

Page 9: ...elow For operation refer to the RapidHeat instruc tions DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a Ground Fault Circuit Interrupter We recommend that a qualified electricia...

Page 10: ...arrant connections of water supply fittings and piping fill systems or drain overflow systems Nor is it respon sible for damage to the bath which occurs during instal lation CAUTION A nonflammable pro...

Page 11: ...e must be repeated starting from step 1 For Bath 1 Press and release the Bath button 2 Press and hold the BLOWER button The LED will flash 3 While holding the BLOWER button press the POWER button for...

Page 12: ...odes will be erased NOTE Batteries installed with incorrect polarity may leak and damage the remote control Do not mix old and new batteries or carbon types with alkaline types REAR SIDE COVER COVER R...

Page 13: ...CLOCKWISE TO REDUCE AIR FLOW TURN COUNTER CLOCKWISE TO INCREASE AIR FLOW AIR INDUCTION CONTROLS DIRECTIONALLY ADJUSTABLE FULLY ADJUSTABLE JETS CD Radio For operation of the CD radio consult the manual...

Page 14: ...yourself into the bath near the intake for the circulation pump Repeat same process with Systems Clean Packet 2 It is important to use Packet 1 before Packet 2 to avoid a strong odor Run the bath for...

Page 15: ...acuzzi Whirlpool Bath makes no representation or warranty regarding and will not be responsible for any code compliance 13 NOTCH GASKET COVER STRAINER SCREW SUCTION FITTING SUCTION COVER STRAINER ASSE...

Page 16: ...14...

Page 17: ...53 mm 182 mm TEMPLATE FOR CD RADIO MOUNTING SLEEVE 15...

Page 18: ......

Page 19: ...acts of God such as lightning floods earthquakes etc In addition THE COMPANY WILL NOT BE RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES or losses arising from any cause e g water damage to carpet...

Page 20: ...obtain warranty replacement for factory installed components for Company supplied options and accessories manufactured and supplied by the Company call or write the above Provide a description of the...

Reviews: