Temperature unit of measure
The temperature scale is set to °C. It can be changed to °F as fol-
lows:
Press and hold the
“Light”
key for about 12 seconds, un-
til the message
“cFn”
appears.
If necessary, use the
“Up”
and/or
“Down”
keys to
scroll the menu until you see the message “
cFn
”. Press the
“Light”
key again to confirm the option.
Now insert the password
123
as follows:
- use the
“Up”
and/or
“Down”
keys to insert the first
number.
- confirm the selection by pressing the
“Light”
key.
Perform the same steps to insert the other two numbers.
Once you have inserted the password, the display will show
the message
I1x
(where “x” may be 1 or 0; the memorized val-
ue is 0).
Use the keys
“Up”
and/or
“Down”
to change “x”
from
0
a
1
(corresponding to the scale in °F). Confirm the se-
lection with the
“Light”
key. The display will show the mes-
sage
I2x
. Press the
“Light”
key again to go to parameter
I3 0
,
which must never be modified
.
Press the
“Light”
key one more time to exit the procedure
and memorize the new values. The display will go off for a mo-
ment, and then it will come on again.
To go back to the Celsius scale (°C), return to the procedure and
set figure “x” of the parameter
I1x
to 0.
NOTE:
If no key is pressed for 20 seconds, you will exit the
procedure and any changes made will not be saved.
Water heating temperature ("set point")
To check or modify the water heating temperature, do the follow-
ing:
Press the
“Up”
or
“Down”
key. The display will show
the current memorized temperature
(in °C or °F as pro-
grammed, see "Temperature unit of measure)
and the respec-
tive symbol appears.
Press the key
“Up”
or
“Down”
again to change the
displayed value from a minimum of15 °C to a maximum of 40
°C (59÷104 °F).
To show the temperature of the water in the tub again, do not
touch any key for about 5 seconds.
Operation of the heater is shown on the display by a symbol
displayed steady.
If instead it is flashing, it means that heat-
ing has been suspended to keep from exceeding the maximum
permitted consumption. See also the previous note.
As soon as the water temperature setpoint is reached, the
heater is shut off. It will not be turned back on until the water
temperature drops about 0.5 °C - 1 °F below the setpoint.
To ensure precise measurement of the water temperature,
the filtering pump comes on every half hour (even if no filtering
cycles are set), since the temperature probe is located in the
heater pipe.
NOTE:
when the system is turned off, or there is a power out-
age, the last setpoint is stored in memory.
Maintenance of minimum temperature of water in tub and
anti-freeze protection of the pipes (“Smart Winter”).
At least every half hour, the system reads the actual tempera-
ture. If it is below the minimum admissible value (15 °C - 59 °F),
the heater and the filtering pump are automatically activated until
the temperature rises above that value.
“Smart Winter” lets you make use of a special probe to moni-
tor the temperature of the compartment under the tub, which con-
tains the all of the pipes of the plumbing circuit. In extreme con-
ditions, the system may turn on this anti-freeze protection (indi-
cated on the display by the message
ICE
). The pumps will be
turned on according to the following configurations:
Light
Clock
Filter
Instant Clear
Blower
Econo
Pump 1
Pump 2
Up
Down
clock
pump 1
pump 2
blower
spotlight
filtering cycle
adjustment
temperature
heater
energy
saving
panel lock
Summary of Contents for SKYLINE
Page 2: ......
Page 3: ...3 1 3 2 4 1...
Page 85: ...85 spa Fill Pump1 Pump2 Light spa spa spa spa Clock 5 Up Down Clock...
Page 89: ...89 1 Pump 1 Pump 2 20 10 20 10 Light 2...
Page 93: ...93 2 3 10 10 pH TA c 2 3 2 3 pH 0 C 0 C Smart Winter...
Page 94: ...94 pH Jacuzzi po lish polish...
Page 95: ...95 Jacuzzi spa 1 2 Jacuzzi A Ja cuzzi 320 1 A 2...
Page 97: ...HPF Jacuzzi cErr 30 Jacuzzi...
Page 98: ......
Page 99: ......