IMPORTANT SAFETY INFORMATION

READ ALL INSTALLATION INSTRUCTIONS
Jacuzzi Whirlpool Bath does not recommend prolonged periods of use of the steamer. Prolonged use of the steam
system can raise excessively the internal human body temperature and impair the body’s ability to regulate its internal
temperature (hyperthermia). Consult your physician about your safety and comfort before using the steam system.
Limit your use of steam to 10–15 minutes until you are certain of your body’s reaction. A cooling shower spray can
be used simultaneously with the steam to assist in regulating your body temperature.

Alcohol and certain drugs or medications, such as tranquilizers, affect a person’s ability to withstand high temperatures
and may produce dangerous side effects. Don’t use alcohol or drugs when using steam.

The elderly, the infirm, and children should not use the steamer unattended. Pregnant women and people with heart
conditions should consult their physicians before using the steamer.

The wet surfaces of steam enclosures can be slippery. Use care when entering and exiting.

Do not place or use electrically connected devices, such as television, radio, or stereo speakers, lights, hair dryers,
or telephones, within 1.5 m (5 feet) of a steam enclosure, shower, or bath.

Read and follow manufacturer’s safety information with all optional equipment.

The steam head is hot. Do not touch the steam head or the steam within one foot distance of the head or surfaces
surrounding the steam head.

Do not block or obstruct the steam head in any manner.

Do not store or use flammable liquids near the steam generator.

Note:  This is a professional grade product.  A good knowledge of construction techniques, plumbing and
electrical installation according to codes are required for proper installation and user satisfaction.  We
recommend that a licensed contractor perform the installation of all Jacuzzi Whirlpool Bath products.  Our
warranty does not cover improper installation related problems.

Optional Accessories

• Steam Enclosure (U194865 Chrome Finish with Clear Glass, U194866 Brass Finish with Clear Glass.

U195865 Chrome Finish with Frosted Glass, U195866 Brass Finish with Frosted Glass

• Dome (U192000)
• Digital Controller with Timer and Temperature Sensor (S063829 Bright Brass).  Chrome Standard  with Unit.
• Automatic Drain Down Valve (S066000)
• Steam Nozzle (E203829 Brass).  Chrome standard and installed on unit.
• Wall Mount Shower Set (C994959 White, C994829 Bright Brass, C994827 Chrome)
• Optica™ 100 Single Handle Mixer (C997959 White, C997829 Bright Brass, C997827 Chrome)
• Large Tear Drop Handle for Optica 100 (C998959 White, C998829 Bright Brass, C998827 Chrome)
• Bright Brass Strainer (A175829)

Summary of Contents for Steam & Shower Base SEDONA

Page 1: ...SEDONA Steam Shower Base INSTALLATION OPERATING INSTRUCTIONS...

Page 2: ...a steam enclosure shower or bath Read and follow manufacturer s safety information with all optional equipment The steam head is hot Do not touch the steam head or the steam within one foot distance...

Page 3: ..._________________________ 8 Finish Materials ______________________________________________________________________ 8 9 Service Access _________________________________________________________________...

Page 4: ...delivery of the products in good order to the carrier Refer any claims for damage to the carrier For definitions of warranty coverage and limitations refer to the published warranty information packa...

Page 5: ...lling the base The use of materials that shim or provide a level installation are allowed provided the method used will ensure a level base that is supported from the bottom Materials that may be used...

Page 6: ...sition when connecting to a drain line To allow steam generator removal for maintenance or service use a straight union DRAIN DOWN OUTLET OPTIONAL AUTOMATIC DRAIN DOWN VALVE DRAIN DOWN VALVE MOUNTED V...

Page 7: ...ing joists to the controller location Note Do not staple through or damage cable An option for tile rooms is to use the 1 gang rough in box provided and install at the desired control mounting locatio...

Page 8: ...installer s responsibility Drain leakage is excluded from the Jacuzzi Whirlpool Bath warranty of this product Slide the shower base into the framed opening and attach the shower base flange to the st...

Page 9: ...unting screws to draw the control housing securely against the finished wall Do not over tighten the mounting screws Install the decorative cover plate by sliding the top of the cover plate over the t...

Page 10: ...included with the sensor If the 7 8 holeisjaggedoriscuttoolargethetrimringmaybeused to cover the exposed edges Make sure that the sensor probe is pointing down once installed Tape the sensor in place...

Page 11: ...with a wood or plastic edge Metal tools will scratch the surface Spots left by plaster or grout can be removed if lightly rubbed with detergent on a damp cloth or sponge Paint tar or other difficult s...

Page 12: ...le element If the steam room temperature drops more than 5 degrees both elements will automatically engage Operation of Your Digital Time and Temperature Control 1 Be sure the power circuit and water...

Page 13: ...vice person For additional assistance or the factory authorized service person nearest you call the Service Department at 1 800 363 0251 This number is only for service for the steam generator The Tro...

Page 14: ...12 Troubleshooting...

Page 15: ...13 Wiring Diagram...

Page 16: ...ble on a national basis for products of this type It is the responsibility of the installer owner to determine specific local code compliance prior to installation of the product Jacuzzi Whirlpool Sho...

Page 17: ...those with manufacturing or workmanship defects for a period of five 5 years from the date of original installation except when the warranted product is installed in commercial locations such as clubs...

Page 18: ...e use or inability to use a warranted product Some States do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the ab...

Page 19: ...or acts of God such as lightning floods earthquakes etc In addition THE COMPANY WILL NOT BE RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES or losses arising from any cause e g water damage to car...

Page 20: ...zi Whirlpool Bath Warranty Service Department P O Drawer J Walnut Creek California 94596 Call 800 288 4002 To obtain warranty replacement for factory installed components for Company supplied options...