Safety Instructions

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS.

This is a professional grade product. A knowledge of construction techniques, plumbing and electrical installation according to 

codes are required for proper installation and user satisfaction. We recommend that a licensed contractor perform the installation 

of all Jacuzzi Luxury Bath products. Our warranty does not cover improper installation related problems.

 

CAUTION

: When using this unit, basic precautions should always be performed, including the following:

 

READ AND FOLLOW ALL INSTRUCTIONS. SAVE THESE INSTRUCTIONS

 

• 

Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the  

 

 manufacturer.

 

• 

Never drop or insert any object into any opening.

 

WARNING: RISK OF ACCIDENTAL INJURY OR DROWNING!  

Do not permit children to use this unit unless they are closely supervised at all times. Do not use hydromassage bathtub 

unless all suction guards are installed to prevent body and hair entrapment. Never operate the hydromassage bathtub if the 

suction cover is broken, damaged or missing.

 

DANGER: RISK OF SEVERE INJURY FROM ELECTRIC SHOCK OR DEATH FROM ELECTROCUTION! 

This unit must be connected only to a supply circuit that is protected by a 15 amp ground fault circuit interrupter (GFCI). 

Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test 

button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate 

in this manner, the GFCI is defective. If the GFCI interrupts power to the bathtub without the test button being pushed, a 

ground current is flowing, indicating a possibility of an electric shock. Do not use this hydromassage bathtub. Disconnect the 

hydromassage bathtub and have the problem corrected by a qualified service representative before using.

 WARNING: RISK OF ELECTRIC SHOCK!  

Connect only to a circuit protected by a ground fault circuit interrupter (GFCI). (For permanently connected units) A green-

colored terminal (or a wire connector) marked “G,” “GR,” “GROUND,” or “GROUNDING”) is provided within the terminal 

compartment. To reduce the risk of electric shock, connect the terminal or connector to the grounding terminal of your 

electric service or supply panel with a conductor equivalent in size to the circuit conductors supplying the equipment.

 

CAUTION: 

This equipment is intended for indoor use only. Install the equipment in accordance with these instructions. Use 

supply wires that are suitable for 167°F (75°C), including the temperature rating of the supply conductors to be used. This 

unit should be electrically grounded and installed by a licensed contractor, electrician, and plumber. Building materials and 

wiring should be routed away from the motor/pump or blower or other heat producing components of this unit. A pressure 

wire connector is provided on the exterior of the motor/pump and heater to permit connection of an No. 8 AWG solid copper 

bonding conductor between this unit and all other electric equipment and exposed metal in the vicinity, as needed to comply 

with local requirements.

Important CSA Safety Instructions (Canadian models only)

  When using this electrical equipment, basic safety precautions should always be followed, including the 

 following:

 

1.   WARNING: RISK OF ACCIDENTAL INJURY OR DROWNING! CHILDREN SHOULD NOT USE HYDROMASSAGE  

 

 

BATHTUB WITHOUT ADULT SUPERVISION.

 

2.  WARNING: RISK OF ACCIDENTAL INJURY OR DROWNING! DO NOT USE HYDROMASSAGE  

 

 

 

 

BATHTUB UNLESS ALL SUCTION GUARDS ARE INSTALLED TO PREVENT BODY AND HAIR ENTRAPMENT.

 

3.  WARNING: TO AVOID INJURY, EXERCISE CARE WHEN ENTERING OR EXITING THE HYDROMASSAGE    

 

 

BATHTUB.

 

4.  WARNING: RISK OF ACCIDENTAL INJURY OR DROWNING! DO NOT USE DRUGS OR ALCOHOL BEFORE OR  

 

 

DURING THE USE OF A HYDROMASSAGE BATHTUB EQUIPPED WITH A HEATER TO AVOID  

 

 

 

 

UNCONSCIOUSNESS AND POSSIBLE DROWNING.

 

5.  WARNING: RISK OF FETAL INJURY! PREGNANT OR POSSIBLY PREGNANT WOMEN SHOULD CONSULT A  

 

 

PHYSICIAN BEFORE USING A HYDROMASSAGE BATHTUB EQUIPPED WITH A HEATER.

 

6.  WARNING: RISK OF HYPERTHERMIA AND POSSIBLE DROWNING: DO NOT USE A HYDROMASSAGE BATHTUB  

 

 

EQUIPPED WITH A HEATER IMMEDIATELY FOLLOWING STRENUOUS EXERCISE.

 

7.   SAVE THESE INSTRUCTIONS.

Summary of Contents for Stella

Page 1: ...iece Tub 5 Overflow Drain Hole Cutouts 5 Installation Instructions for 2 Piece Tub 6 Installation Instructions for Remote Blower 6 Installation Instructions for 2 Piece Tubs with Whisper Technology or...

Page 2: ...tected by a ground fault circuit interrupter GFCI For permanently connected units A green colored terminal or a wire connector marked G GR GROUND or GROUNDING is provided within the terminal compartme...

Page 3: ...drugs or medication can greatly increase the risk of fatal hyperthermia People using medications or having an adverse medical history should consult a physician before using a hydromassage bathtub equ...

Page 4: ...urn bathtub to box or otherwise protect from damage until time of installation Bathtub Water and Operational Test Prepare the sub floor for the drain and ensure that the area is level 1 The drain over...

Page 5: ...low extends below the bottom of the bath The drain overflow requires a cutout of the floor for providing space to accommodate the extension Do not exceed the dimensions of the tub perimeter When the a...

Page 6: ...r When the above locations have been marked on the floor remove the tub base skirt set it aside and continue with the installation process Faucetry is not supplied with the freestanding bath To use de...

Page 7: ...iece where it will connect to the drain alignment kit Fig 9 Place 2 four foot long 2 x 4 wood supports across the top of the skirt Position the wood supports evenly over the skirt as illustrated Fig 8...

Page 8: ...the Linear DWO kit 5 Glue the brass tailpiece assembly to the direct drain as shown Fig 13 1 Apply silicone to bottom flange of bath tub skirt Apply grease to the brass tailpiece 2 Carefully lower the...

Page 9: ...ructions outlined in this manual In the event that damage to the bath such as minor scratching to the surface is inadvertently incurred a qualified professional may be able to restore the luster of th...

Page 10: ...Page 10 www jacuzzi com Installation Instructions Freestanding Baths English Notes...

Page 11: ...Jacuzzi Luxury Bath 14525 Monte Vista Avenue Chino California 91710...

Page 12: ...duct Features Brand Name Price Hydrotherapy Home Resale________________________ Other______________________________ 4 Who finally decided which product you would buy Self Spouse Self and Spouse Togeth...

Reviews: