Now that your Quantum Plus spa is in place, you are probably eager to take advantage of its unique designed-in features—

especially the patented Jacuzzi Whirlpool Bath hydromassage performance. Besides being a beautiful addition to your
indoor decor or outdoor landscaping, your Jacuzzi whirlpool spa will provide you with the ultimate in spa pleasure.

Basic Control Set-Up

The control set-up on your Quantum Plus spa is designed to give you fingertip control of the heater, lights, air induction,

Water Rainbow and whirlpool/filter pump and blower systems of your unit from inside or outside your spa.  Follow the basic
control set-up described below to familiarize yourself with the several functions of the control panels located on the top of
the spa.

CAUTION

Do not turn on power to the spa unless it is filled with water to the normal water level.  (See water line indicatormark
on skimmer frame.)  When the power is on, the built-in timer may activate the system even though the SYSTEM is
turned off at the control panel.  If the spa’s motor/pump is actuated when there is not sufficient water in the unit,
the circulation pump and heater could be irreparably damaged.    In addition to damaging the unit, operating the
spa with insufficient water could cause a fire.

SYSTEM CONTROL MODULE

Using a garden hose, fill the spa with water to the
waterline indicator mark on the skimmer frame.  (See
page 20 for information on using Water Rainbow as a
fill spout if desired.)

At the house service panel, turn on the circuit breaker
or switch that controls the electrical service to your spa.
(Make sure there is no other appliance on that circuit.)

Open the skirt door giving access to the System Control
Module.

Your spa is provided with a earth leakage circuit breaker
(ELCB). At initial start-up and at least once a month
thereafter, with power on, push the button located on
the spa System Control Module.  The switch should
move to the OFF (O) position.  Move the switch to the
ON (1) position to reset.  If the interrupter fails to operate
in this manner, there is a ground current flowing or a
device malfunctioning, indicating the possibility of elec-
tric shock. Turn off power and do not use the spa until
the source of the breakdown has been identified and
corrected.

HIGH TEMPERATURE SAFETY SWITCH

High temperatures above the thermostat range
will cause the high temperature safety switch to
trip and the system to turn off.  See operating
instructions.  When water temperature is less
than 100

°

 F., reset by pressing the safety switch

reset button located on the cover of the heater
enclosure.

CAUTION:  DO NOT BREAK DOOR SEAL;

OPENING DOOR VOIDS W ARRANTY

THIS EQUIPMENT REQUIRES QUALIFIED SERVICE
PERSONNEL FOR PROPER REPAIR.  CONTACT YOUR
JACUZZI WHIRLPOOL BATH DEALER FOR SERVICE.

NO USER SERVICABLE PARTS BEHIND THIS DOOR.

CAUTION

This system is GFCI (Ground Fault Circuit Interrupter) pro-tected for your
safety.  Bypassing the GFCI or tampering with the system in any way may
cause electrical shock, in-jury or death and will void the warranty.  GFCI
protection does not extend to 230 V AC circuit conversion.  If test indi-cates
that the GFCI is not functioning, DO NOT  USE THE UNIT  until the electrical
problem has been corrected. (See installation instructions.)   TEST  THE GFCI
ONCE A MONTH.

TEST PROCEDURE
Unit must be filled to proper water level and correct power supplied.

1. Push TEST button of GFCI.

2. RESET button should pop out.  This should cut off power

to the system.  CAUTION: if RESET button does not
pop out, or if RESET  button does pop out and system
is still on, DO NOT USE YOUR SPA.

3. If the GFCI tests okay, restore power by pushing in the

reset button.  The RESET button must be pushed until

it locks into place and remains depressed.

IF THE GFCI FAIL TO RESET PROPERLY, DO NOT USE
THE SPA!  CONTACT A  QUALIFIED ELECTRICIAN.

FLOW

SWITCH

TEMP.

SAFETY

SWITCH

INTERLOCK

SWITCH

LIGHT #1

LIGHT #2

Turn dial to correct time and day.  Slide tabs

toward center for desired operating periods.
(One tab = 2 hrs.)

HEATER

BLOWER

JETS

MOT OR/

PUMP

FILTER

MOT OR/

PUMP

GFCI

TIMER

PLUG-IN
C0NNECTORS

Summary of Contents for The Quantum Plus

Page 1: ...TM Portable Whirlpool Spa Owner s Manual The Quantum Plus...

Page 2: ...tion pump and may cause a fire Read manufacturer s safety information provided with all optional equipment Jacuzzi Whirlpool Bath does not recommend spa water temperatures in excess of 40 C 104 F High...

Page 3: ..._______________________ 11 Silent Air Induction _______________________________________ 11 Filtration _______________________________________________ 11 Maintenance ___________________________________...

Page 4: ...ftwopatented front loadskimmer filtersformaximumefficiency Theunique 4 65m2 50 sq feet filtration system designed by Jacuzzi Whirlpool Bath allows easy access from inside the spa to both filter cartri...

Page 5: ...kirt panels and the acces sory package which contains the Owner s Manual filter cartridges and extra lenses and bulbs Set aside skirt panels until equipment set up Set aside the filter cartridges in a...

Page 6: ...mes from the factory requires a 230 VAC 50 AMP 4 wire grounded type electri cal service and must be in a separate circuit having no otherapplianceconnectedinthatcircuit Ifyoudonothave this kind of cir...

Page 7: ...nstallation If you install the spa outdoors we recommend that you provide a concrete pad for it to rest on To do this construct forms for a 8 x 8 x 4 thick level pad Install a 10 gauge wire mesh appro...

Page 8: ...plastic sheet covering the spa Use care stepping into the spa with shoes will scratch the acrylic surface 2 Remove any packing materials from the spa 3 Remove each filter cartridge from its plastic ba...

Page 9: ...position Move the switch to the ON 1 position to reset If the interrupter fails to operate in this manner there is a ground current flowing or a device malfunctioning indicating the possibility of ele...

Page 10: ...e reason the switches are tripped the reset button must be pushed in for the heater to operate again after the water has cooled to about 38 C 100 F Set the built in timer see below Use of the timer al...

Page 11: ...FILTER The next selection is OFF again Use the JETS function as a reference to indicate your location in the function sequence since that function is the most obvious when operating For best performan...

Page 12: ...as just turned off the indicator lamp on the control panel will turn off at this time 10 OPERATION Temperature Control Turn on the heater by selecting the HTR FILTER mode on the SYSTEM selector switch...

Page 13: ...fully adjustable jets will dramatically increase the Water Rain bow flow CAUTION The water circulating through the Water Rainbow spouts is not fresh water and therefore is not suitable for drinking A...

Page 14: ...its pores The addition of clarifier will make the water clearer but clogged filters must be cleaned as prescribed under the section entitled Filter Maintenance in this manual Hard Water Add a de miner...

Page 15: ...used heavily change the water at least every month pH A chemical term used in expressing relative acid ity or alkalinity in numeric values with 7 0 usually regarded as neutral and for purposes of this...

Page 16: ...nd winds etc accumulate in the spa and cannot be filtered out it is necessary to drain your spa and refill it with fresh water This should be done every 2 months or more often depending on the amount...

Page 17: ...idges clean them and store them dry 5 Keep water and debris out by covering with a rigid spa cover 6 Before using the spa again review the Operating In structions CAUTION Not winterizing will cause ir...

Page 18: ...n forced polyester resin A catalyst causes a chemical reac tion during manufacture that bonds these layers perma nently into a hard strong material With a minimum amount of care and cleaning your whir...

Page 19: ...Heater not functioning but heater light on A B C A Clogged or blocked suction strainer or skimmer basket B Filter clogged dirty C Poor water chemistry D Insufficient filtering time E Improper mainten...

Page 20: ...our power company A Turn on power at service panel B Select other function C Reset circuit breaker D Reset circuit protector E Reset button s on heater after water has cooled see Note if switch contin...

Page 21: ...D Inadequate supply wiring E High temperature safety switches tripped A Let cool for one hour Motor overload protector will reset if problem persists see Note B C D Consult electrician to cor rect wir...

Page 22: ...Do not interconnect water supply with recirculating system of the spa To make the connections necessary to use the Water Rainbow as a fill spout follow this procedure Make sure spa is unplugged and c...

Page 23: ......

Page 24: ...vailable on a national basis for products of this type It is the responsibility of the installer owner to determine specific local code compliance prior to installation of the product Jacuzzi Whirlpoo...

Reviews: