34
- If the message “
FLO
/FLC
”
appears on the display, alternating with
the temperature value
, the heater pressure switch/flow switch may
be faulty. Please see the “Abnormal operating conditions – alarm
signals” chapter.
Press the TEST button of the differential switch located up-
stream from the electrical system to which the hot tub is con-
nected. If it does not trip, it may be faulty or it may have tripped
due to problems in the electrical system of the building.
Disconnect the hot tub and do not use it until you have iden-
tified and eliminated the defect.
Check the operation of the pumps
and:
- briefly press the “Pump”
button (display A1) to turn pump
1 on/off
(the button briefly lights up blue, then returns to white);
- press the “Pump”
button (display A2) to turn pump 2 on/off
(the button briefly lights up blue, then returns to white);
- press the “Pump”
button once (display B) to turn on pump
1; press it again to turn on pump 2. Press the button a third
time to turn off pump 1 and a fourth time to turn off pump 2.
Check that the spotlight switches on and off using the “Light”
key
(display B) and then the
key (display A1/A2).
Check that there are no leaks from the hydraulic connections
or other problems.
Completely disinfect the hot tub by carrying out “super-chlo-
rination” treatment
.
Please refer to the Jacuzzi system water treatment guide
and relative catalogue for details on water quality mainte-
nance, the methods and warnings governing the use of rela-
tive chemical products.
Make a note of the pressure value shown on the filter pres-
sure gauge
.
Note: regularly check the pressure value shown by filter. If
this value increases by max. 0.2 atm with respect to the ini-
tial value, the filter needs to be backwashed (see the use and
maintenance manual).
After a few hours, turn off the omnipolar switch.
Open the drain valveand completely empty the hot tub.
If included, re-install the front and side panels.
CAUTION
m
Do not use the hot tub the first time you start it as there
is a high concentration of chlorine in the water during
this phase. Immediately empty the bath.
Contact the local authorities for the standards govern-
ing the discharge of chemically treated water.
Close the drain valve(s) and fill the hot tub again with fresh
water as previously explained.
Turn the omnipolar switch back on and check that the hot
tub works correctly.
A1
B
A2
6
0
pump
spotlight
viewing and adjusting temperature,
parameters, functions
Temperature adjustment LED
heater LED
filtering LED
Summary of Contents for VIRTUS
Page 2: ...2...
Page 9: ...9 1 2 3 1 0...
Page 10: ...10 click 2 3 clack 1 4 5x40 mm 2a 2b 1 2a 2b 1 6 6 4 5 2 0...
Page 12: ...12 2 1 3 6 7 8 10 9 PUMP POOL s s s 3b 0...
Page 13: ...13 2 9x19 mm 2 5 mm 1 2 3 1 2 2 3 3 4 0...
Page 92: ...92 16 dip switch 1 16A dip switch 1 V V V spa m m 1 2 m BACKWASH...
Page 100: ...100 ON smart winter...
Page 101: ...101 B2 dip switch 2 LL L1 L2...
Page 102: ...102 Jacuzzi Jacuzzi Jacuzzi Europe S p A Jacuzzi Eco Heat Cool Power b1 b2 b1 b2 b1 b2...
Page 103: ...103...