36
Refer to the heat pump and/or hot tub manual for usage
warnings.
■
M
aintenance
of
MiniMuM
teMperature
of
water
in
tub
and
anti
-
freeze
protection
of
tHe
pipes
(“s
Mart
w
inter
”).
“Smart Winter” mode lets you make use of a special probe to
monitor the temperature of the compartment under the tub, which
contains the all of the pipes of the plumbing circuit. In extreme
conditions, the system may turn on this protection (indicated on
the display by the message
ICE
), switching on the pump(s) and the
blower (where present).
ATTENTION: In the case of particularly low temperatures
specifically, check the electrical power supply regularly to
ensure that the function is not interrupted.
The pumps are turned on at pre-set intervals:
NOTES
- If the temperature of the compartment drops rapidly, the frequen-
cy of activation increases.
- If it becomes necessary to turn on the anti-freeze protection during
a filtering cycle, these will be suspended and resume when the cycle
is complete.
- If it is necessary to perform an anti-freeze cycle while a function
activated by the user is in progress, the cycle will be activated 15
minutes after the end of the function.
- If this protection is active, the spotlight may still be turned on.
■
“e
nergy
savings
”
Mode
(“
eco
”
function
)
When this function is on, the water heater only turns on again when
the temperature drops to approximately 10°C (50°F) below the set-
point.The minimum permitted temperature is 15°C.
Press the “Up/Down”
button: the current temperature is
displayed.
While the LED above the thermometer symbol is on, hold
down the “Light”
button for approximately 5 seconds: when
the button is released the screen briefly shows the new refer-
ence value alternated with the word "Eco"; then, the current
temperature will appear again.
To turn the function off, proceed as indicated above (press
the “Up/Down”
button, etc.).
NOTE:
- To check the function status
, press the “
Up/Down
”
button: if
“Eco” appears, the function is on.
- Do not set the "energy saving" mode if the heat pump is used for
cooling water (Jacuzzi® Cool Power heat pump).
Water filtering
The water needs to be filtered to keep it clean and clear. This option
is active during the day as follows:
- two filtration cycles that are repeated every 12 hours.
Each filtration cycle is has an initial phase, in which the pump
and the blower (where present) are turned on one at a time for
approximately one minute; then the cycle continues, activating
the Clearray™ Pro3tect™ and the filtration pump for the remain-
ing time.
■
s
etting
tHe
filtering
cycles
To set the filtering cycle:
Hold down the “Pump”
button for approximately 5 sec-
onds: dx
(where “x” indicates the duration in hours) appears on the
screen.
Use the “Up/Down”
button to enter the desired duration
(from a minimum of 0 to a maximum of 12 hours)
.
NOTE:
press and hold the button until you reach the desired val-
ue; by releasing the button and pressing it again, the adjustment is
made in the opposite direction.
Press the “Pump”
button again and the selected value is
confirmed, and the cycle start delay is programmed with re-
spect to the "0" time
(
sy
parameter where “y” indicates the num-
ber of hours).
WARNING:
time "0" is the instant when power is supplied to the hot
tub through the main switch or the time when the parameters are
stored; if, for example, the value "4" is set as the start delay of the
cycle, this means that the filtration will start 4 hours after turning
on the hot tub, or after storing the parameters; it is also possible to
reduce the parameter value to 0 “
s
”: In this case, the filtration cycle
will start immediately.
Set the start delay
(from a minimum of 0 to a maximum of 12)
using the “Up/Down”
button and confirm the value with the
“Pump”
button to store the values inserted and to exit the
programming mode.
When the function is active, the LED of the respective symbol
lights up
(if it flashes, it means that the cycle has been suspended;
see relative section).
During the filtering cycles, “Flt” appears on the screen.
NOTES
If no key is touched for about 5 seconds, the device exits “parame-
ter-setting” mode.
If there is a power outage, the data in the memory is saved, but the
time “0” will become the moment at which the electricity comes
back on. Therefore, it may be necessary to turn the main switch up
the line from the hot tub off and back on to re-align the cycle start
delay with the memorized parameters.
Summary of Contents for VIRTUS
Page 2: ...2...
Page 9: ...9 1 2 3 1 0...
Page 10: ...10 click 2 3 clack 1 4 5x40 mm 2a 2b 1 2a 2b 1 6 6 4 5 2 0...
Page 12: ...12 2 1 3 6 7 8 10 9 PUMP POOL s s s 3b 0...
Page 13: ...13 2 9x19 mm 2 5 mm 1 2 3 1 2 2 3 3 4 0...
Page 92: ...92 16 dip switch 1 16A dip switch 1 V V V spa m m 1 2 m BACKWASH...
Page 100: ...100 ON smart winter...
Page 101: ...101 B2 dip switch 2 LL L1 L2...
Page 102: ...102 Jacuzzi Jacuzzi Jacuzzi Europe S p A Jacuzzi Eco Heat Cool Power b1 b2 b1 b2 b1 b2...
Page 103: ...103...