b. Otherwise, replace the pressure switch to gain dependability.
IF shorting out the pressure switch does NOT solve the problem, the failure is the
board itself. Double check that the pressure switch cord to make sure it’s plugged
securely into the board and the cord isn’t cut. IF not, your short is telling the board
water movement is happening and it’s ignoring the signal. This rarely happens but
when it does, you have to replace the board.
The CLICKS are not over:
After the pump and heater come on and don’t touch any topside control, you will
hear another CLICK. That is the ozonator being turned on.
Summary:
a. Power up spa.
b. If no CLICK:
Cause: Incorrect or no power OR bad board.
c. Get 1
st
Click but not Second:
Cause: Board, sensor, or pressure switch failure.
d. Get 1
st
and 2
nd
Click but not 3
rd
.
Cause: Pump failure, pressure switch failure, or board failure.
e. Get 1
st
, 2
nd
, and 3
rd
but No Heater Light
Cause: Pressure switch or board failure.