background image

 

42 

 

 

9/10/15 

Appendix C - Symbology Chart 

[This Appendix may go away completely per internal discussion... or the full 

Symbology Chart below may be replaced with a chart containing only the HS2R9 

supported symbologies (see Artwork folder).   

 

 

 

Summary of Contents for Flexpoint HS2R9

Page 1: ...Flexpoint HS2R9...

Page 2: ...ecommendations 8 Proper Disposal of the Battery 9 Connecting the Base 10 Reading Techniques 11 Chapter 2 Basic System Operation 12 Base 12 RF Radio Frequency Module Operation 12 Cordless HS2R9 12 Syst...

Page 3: ...ce Cable 28 Replacing the Battery 28 Repairs 28 Chapter 10 REGULATORY Service Maintenance 29 10 1 FCC IC 29 FCC Class B Compliance 29 10 2 Industry Canada IC Compliance 30 10 3 CE 31 10 4 Customer Sup...

Page 4: ...x C Symbology Chart continued 43 Appendix D Data Matching Collation Needs 7 bit commands 44 Appendix E GS1 Formatting Needs 7 bit commands 47 Appendix F Japan 2 Byte Output Mode Needs 7 bit commands 5...

Page 5: ...thcare applications and environments The HS2R9 has a sealed housing that protects it from day to day debris and spills and is built with medical grade plastics that are compatible with popular medical...

Page 6: ...ring The configuration string defines the configuration style of the HS2R9 unit Please consult the factory for configuration information Revision String The revision string indicates the revision numb...

Page 7: ...7 9 10 15 flexpoint HS2R9 Imager Components...

Page 8: ...shipped approximately 30 to 60 charged and should be fully charged for maximum charge capacity The battery is a lithium ion cell and can be used without a full charge and can also be charged without...

Page 9: ...working properly please see the troubleshooting section in Chapter 2 Proper Disposal of the Battery When the battery has reached the end of its useful life the battery should be disposed of by a quali...

Page 10: ...r LEDs flash alternating between the green and red LED to indicate the battery is charging If only the red LED is flashing this indicates the unit is charging but the voltage charge is too low to allo...

Page 11: ...to the code and larger when it is farther from the code Symbologies with smaller bars or elements mil size should be read closer to the unit Symbologies with larger bars or elements mil size should be...

Page 12: ...data packets at a fast data rate over a radio signal with randomly changing frequencies making the cordless system highly responsive to a wide variety of data collection applications and resistant to...

Page 13: ...ned located in the well of the base in front of the contact pins the HS2R9 will begin the association process with the Bluetooth module in that base If a regular barcode is scanned the HS2R9 will begi...

Page 14: ...icate this by flashing the red and green LEDs alternately If the battery charge falls below 3 2 Volts during use the red LED will stop blinking and the HS2R9 will enter sleep mode to preserve battery...

Page 15: ...tooth association attempt succeed Blinking Off Battery critically low if discharging system ill shut down shortly Blinking Off Battery too low to power hand held up if in the cradle The battery is cha...

Page 16: ...d On On In base base not powered both LED s on constantly This state will persist for about 2 minutes then the unit will completely power down The only way to wake it is to plug it into a powered base...

Page 17: ...increasing frequency Varying Power up Bluetooth Association Geiger counter beep Bluetooth associating with base opening connection Two ascending beeps Varying Bluetooth association successful One long...

Page 18: ...time it takes to transition from a single flashing red LED state to alternating red and green LED state will depend on how discharged the battery was before placing into the base This could take 30 6...

Page 19: ...luetooth association the HS2R9 will flash the green LED and emit a single short high frequency beep HS2R9 Scanner will not send data to the host If the HS2R9 is associated with the base but no data is...

Page 20: ...faults All Symbologies Linear Symbologies Codabar Code 11 Code 128 Code 2 of 5 Code 39 Code 93 EAN JAN 13 EAN JAN 8 GS1 DataBar Expanded formerly RSS Expanded GS1 DataBar Limited formerly RSS Limited...

Page 21: ...p You may wish to set the same value for minimum and maximum length to force the imager to read fixed length bar code data This helps reduce the chances of a misread EXAMPLE Decode only those bar code...

Page 22: ...22 9 10 15...

Page 23: ...Length Width Weight 1 31 inches 34 4 mm 4 6 inches 116 8 mm 2 02 inches 51 3 mm 4 0 ounces 113 4 g Aimer Illumination LEDS Aiming LEDS 626 nm 30 nm 526 nm 30 nm Image VGA 752x480 Skew Angle 40 degrees...

Page 24: ...ase Presentation Mode HS2R9 Base without Handheld Scanning Standby Inrush 475 mA 125 mA 950 mA 200mA 100mA 700mA Power Supply Noise Rejection Maximum 100 mV peak to peak 10 to 100 kHz Radio Frequency...

Page 25: ...25 9 10 15 Parameter Specification MTBF Per MIL HDBK 217F Ground Benign exceeds 100 000 hours Sealant Rating IP54...

Page 26: ...ty or if the scanner isn t operating well clean the window with a soft cloth or lens tissue dampened with water or a mild detergent water solution If a detergent solution is used rinse with a clean le...

Page 27: ...llon water Dispatch No dilution required Hibiclens 25 6 oz gallon water LpH Disinfectant Cleaner 0 5 oz gallon water Maxima 128 1 oz gallon water Metrizyme 1 oz gallon water Mild detergent Per manufac...

Page 28: ...d Note The use of non JADAK cables voids the warranty only a JADAK cable can be used to keep the IP54 rating Replacing the Battery Replace the battery in the HS2R9 with a battery supplied by JADAK onl...

Page 29: ...o comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential inst...

Page 30: ...in excess of Health Canada limits for the general population consult Safety Code 6 obtainable from Heath Canada s website www hc sc gc ca rpb This device complies with Industry Canada licence exempt R...

Page 31: ...une antenne d un type et d un gain maximal ou inf rieur approuv pour l metteur par Industrie Canada Intentional Radiator Modular Certification of the HS2R9 The HS2R9 also contains intentional radiator...

Page 32: ...harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits EMC DIRECTIVE 2004 108 EC as amended Council Directive of December 15 2004 on...

Page 33: ...1 2008 LED Safety EN 50581 2012 RoHS EN 55024 2010 Immunity EN 55022 2010 EME EN 61000 3 2 2006 A1 2009 A2 2009 Harmonics current 16A EN 61000 3 3 2008 Flicker current 16A ICES 003 Issue 5 2012 Emissi...

Page 34: ...ted purchase record attached Contact the appropriate location below to obtain a Return Material Authorization number RMA before returning the product If you need assistance installing or troubleshooti...

Page 35: ...ther than JADAK or its authorized representatives This warranty shall extend from the time of shipment for the duration published by JADAK for the product at the time of purchase Warranty Period Any d...

Page 36: ...TY OF SUCH INJURIES LOSSES OR DAMAGES SOME STATES PROVINCES OR COUNTRIES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT A...

Page 37: ...37 9 10 15 Appendices Appendix A Programming Bar Codes...

Page 38: ...38 9 10 15...

Page 39: ...39 9 10 15 Appendix B ASCII Conversion Chart...

Page 40: ...40 9 10 15...

Page 41: ...41 9 10 15 Appendix B ASCII Conversion Chart continued...

Page 42: ...endix C Symbology Chart This Appendix may go away completely per internal discussion or the full Symbology Chart below may be replaced with a chart containing only the HS2R9 supported symbologies see...

Page 43: ...43 9 10 15 Appendix C Symbology Chart continued...

Page 44: ...44 9 10 15 Appendix D Data Matching Collation Needs 7 bit commands...

Page 45: ...45 9 10 15...

Page 46: ...46 9 10 15...

Page 47: ...47 9 10 15 Appendix E GS1 Formatting Needs 7 bit commands...

Page 48: ...48 9 10 15...

Page 49: ...49 9 10 15...

Page 50: ...a wireless Bluetooth BLE handheld scanner capable of decoding all major 1d and 2d barcode varieties as well as reading a broad variety of HF RFID tags The HS2R9 consists of a highly configurable area...

Page 51: ...g to read ISO 15693 tags as our current customer requirements are only for that tag type Alternating the operational modes described above reduces current draw to extend battery life The beeper is als...

Page 52: ...a flex circuit and connector on the interface board The antenna is shielded on both along the length of the flex tail up to the loop portion The shield is tied to the ground trace on the antenna which...

Page 53: ...hat allows for independent selection of and activation of all supported tag types The new command added to the firmware is RF_TEST which allows the following values which incorporate all supported RFI...

Page 54: ...54 9 10 15 between any of the individual techniques please scan first the RF_TEST 0 barcode and then scan the other barcode mode 1 4 that you wish to enable...

Page 55: ...ains a red 640 660nm 1mW class 2 Laser Aimer It conforms to the requirements of IEC EN 60825 1 2001 under all operating conditions and meets the accessible radiation limits AELs required for a Class 2...

Page 56: ...56 9 10 15...

Reviews: