INSTALLATION AND GAS PIPING 
 

A qualified installer, service agency or gas supplier must perform installation and service. 
 

  If equipped, the appliance is supplied with a three-prong (grounding) plug for your protection 

against shock hazard and should be plugged directly into a properly grounded three-prong 
receptacle.  Do not cut or remove the grounding prong from this plug. 

 

  The installation must conform with local codes, or in the absence of local codes, in the USA, 

National Fuel Gas Code ANSIZ223.1-latest edition and in Canada, CAN.CGA-B149.1 and 
CANCGA-B149.2 “Installation Code for Gas Burning Appliances.”  Electrical installation 
must conform to latest edition of National Electrical Code, ANSI/NFPA70 in the United 
States, and CSA Standard C22.1 Canadian Electrical Code Part I in Canada. 

 

  Level appliance.  Adjustable legs are provided.  If the appliance is equipped with casters, 

the installation shall be made with a connector that complies with the Standard for 
Connectors for Movable Gas Appliances ANSI-Z21.69-latest edition and a quick-disconnect 
device that complies with the Standard for Quick-Disconnect Devices for Use with Gas Fuel, 
ANSI-Z21.41-latest edition.  In Canada, the flexible connector must be CGA approved and 
comply with the CAN1 6.10.88.  Quick disconnect must comply with CAN1 6.9.M79. 

 

  Adequate means must be provided to limit the movement of the appliance without 

depending on the connector and the quick-disconnect device or its associated piping to limit 
the appliance movement.  The restraining means may be attached to the rear of appliance 
by cable and hook. 

 

  The appliance shall be installed with the following minimum clearances to adjacent 

construction: 

 

 

Combustible 

Non-combustible 

 

Without Unit Broiler 

With Unit Broiler 

 

Sides 

6 inches 

9 inches 

0 inches 

Rear 

3 inches 

6 inches 

0 inches 

Floor 

6-inch legs 

6-inch legs 

0 inches 

 

 

 

 

 

  A conveniently located gas shutoff valve, external to the appliance is required for complete 

shutdown. 

 

  Be sure all valves are in a closed position before connection to gas supply. 

 

  Connect appliance to gas supply line.  Under no circumstances should the gas supply line 

be smaller than the inlet pipe on the appliance.  Use pipe compound on all pipe joints.  
Compound must be resistant to the action of liquefied petroleum gases.   

 

  Check all gas connections for leaks using a soap and water solution.  

DO NOT USE AN 

OPEN FLAME FOR CHECKING PURPOSES.

 

 

Summary of Contents for JSR

Page 1: ...or obstacles that may obstruct the flow of combustion and ventilation air FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other applia...

Page 2: ...he Standard for Quick Disconnect Devices for Use with Gas Fuel ANSI Z21 41 latest edition In Canada the flexible connector must be CGA approved and comply with the CAN1 6 10 88 Quick disconnect must c...

Page 3: ...ly valve to let gas to flow into the appliance Wait 5 minutes 2 Light lighters 3 Adjust lighter flames by using a screwdriver to turn lighter valve screw clockwise or counter clockwise Good flame char...

Page 4: ...and top burner pilots ignited continue with lighting the oven pilot 1 Flip master toggle switch to ON position The indicator light will glow 2 Remove oven kick plate 3 Push red button of safety pilot...

Page 5: ...TE If removing hot plates for any reason remember to replace the plate s with the underside exhaust gas opening of the plate towards the rear All plates should fit tightly and flat to each other Once...

Page 6: ...service function the satisfactory operation of the automatic gas ignition system pilot safety should be verified If it becomes necessary to replace any gas control device such as a main burner valve...

Page 7: ...989 and a quick disconnect device that complies with the Standard for Quick Disconnect Devices for Use with Gas Fuel ANSIZ21 41 1989 Adequate length must be provided to limit the movement of the appli...

Reviews: