background image

 

 
P/N 2412800000 REV. C 6/2011 

 

Page 4 

 

The

 

convection oven has

 

a pilot re-ignition safety feature.  This feature runs on 120V system 

using the pilot, thermocouple and Baso safety valve.  To operate the pilot re-igniter, the master 
electric switch (toggle switch) located at the control panel must remain in “ON” position.  If the 
pilot flame and oven burner flames are extinguished by drafts or temporary loss of gas (less 
than 5 seconds) the pilot will attempt to re-ignite by sparking.  Should the thermocouple cool 
down (over 5 seconds) the safety valve closes and shuts down the gas supply to the oven 
burner.  The sparking will 

NOT

 stop until the pilot flame is re-established while the unit is under 

power. To re-establish the pilot flame, follow the lighting procedures below.  
 
 

Convection Oven Section Lighting Procedure:

 

 
With main gas supply on and top burner pilots ignited, continue with lighting the oven pilot  
 
1.  Flip master toggle switch to “ON” position.  The indicator light will glow. 
 
2.  Remove oven kick plate. 
 
3.  Push red button of safety pilot valve and light pilot.  Continue to push red button until pilot 

flame remains on (minimum of 30 seconds).  Release button. 

 
4.  Turn oven gas valve to fully on position. 
 
5.  Turn thermostat dial to desired temperature. Check oven burner ignition. 
 
6.  Check if pilot flame is extinguished of not. 
 
7.  Turn off thermostat. 
 
8.  Check pilot flame (still ignited). 
 
9.  Replace oven kick plate. 
 
 

Convection Oven Section Operation 
 

1.  Turn oven gas valve to fully on position. 
 
2.  Turn thermostat to desired temperature. 
 
3.  Flip blower toggle switch to “AUTO” position to turn blower on. 
 
 
 
    
 

 

If it is necessary to lower oven temperature very rapidly to accommodate a different product, 
simply adjust thermostat to the lower selected temperature.  Open oven door and flip blower 

CAUTION: 

When possible,

 DO NOT 

operate convection oven 

with oven blower OFF for more than 2 minutes. 

Summary of Contents for JSR

Page 1: ...or obstacles that may obstruct the flow of combustion and ventilation air FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other applia...

Page 2: ...he Standard for Quick Disconnect Devices for Use with Gas Fuel ANSI Z21 41 latest edition In Canada the flexible connector must be CGA approved and comply with the CAN1 6 10 88 Quick disconnect must c...

Page 3: ...ly valve to let gas to flow into the appliance Wait 5 minutes 2 Light lighters 3 Adjust lighter flames by using a screwdriver to turn lighter valve screw clockwise or counter clockwise Good flame char...

Page 4: ...and top burner pilots ignited continue with lighting the oven pilot 1 Flip master toggle switch to ON position The indicator light will glow 2 Remove oven kick plate 3 Push red button of safety pilot...

Page 5: ...TE If removing hot plates for any reason remember to replace the plate s with the underside exhaust gas opening of the plate towards the rear All plates should fit tightly and flat to each other Once...

Page 6: ...service function the satisfactory operation of the automatic gas ignition system pilot safety should be verified If it becomes necessary to replace any gas control device such as a main burner valve...

Page 7: ...989 and a quick disconnect device that complies with the Standard for Quick Disconnect Devices for Use with Gas Fuel ANSIZ21 41 1989 Adequate length must be provided to limit the movement of the appli...

Reviews: