background image

 

 
P/N 2412800000 REV. C 6/2011 

 

Page 6 

 
 
It is strongly suggested that a trained gas appliance service company examine the appliance at 
least yearly. 
 

REPAIR GUIDELINES 

 
All repair work must be completed by a licensed, trained service person experienced in 
commercial gas food service equipment. 
 
During any service function, the satisfactory operation of the automatic gas ignition system (pilot 
safety) should be verified.  If it becomes necessary to replace any gas control device, such as a 
main burner valve, safety valve, thermocouple, etc., the replacement part should be ordered 
from the factory only, unless it has been determined that the 

EXACT

 part is available from your 

local parts supplier. 
 
 

SUPREME CONVECTION OVEN WIRING DIAGRAM 

 

 

NOTE:

  A WIRING DIAGRAM CAN BE FOUND ON THE INSIDE OF THE OVEN KICK   

 

 PLATE. 

Summary of Contents for JSR

Page 1: ...or obstacles that may obstruct the flow of combustion and ventilation air FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other applia...

Page 2: ...he Standard for Quick Disconnect Devices for Use with Gas Fuel ANSI Z21 41 latest edition In Canada the flexible connector must be CGA approved and comply with the CAN1 6 10 88 Quick disconnect must c...

Page 3: ...ly valve to let gas to flow into the appliance Wait 5 minutes 2 Light lighters 3 Adjust lighter flames by using a screwdriver to turn lighter valve screw clockwise or counter clockwise Good flame char...

Page 4: ...and top burner pilots ignited continue with lighting the oven pilot 1 Flip master toggle switch to ON position The indicator light will glow 2 Remove oven kick plate 3 Push red button of safety pilot...

Page 5: ...TE If removing hot plates for any reason remember to replace the plate s with the underside exhaust gas opening of the plate towards the rear All plates should fit tightly and flat to each other Once...

Page 6: ...service function the satisfactory operation of the automatic gas ignition system pilot safety should be verified If it becomes necessary to replace any gas control device such as a main burner valve...

Page 7: ...989 and a quick disconnect device that complies with the Standard for Quick Disconnect Devices for Use with Gas Fuel ANSIZ21 41 1989 Adequate length must be provided to limit the movement of the appli...

Reviews: