background image

8

SPECIFICATION

Power voltage

220V-240V 50-60Hz 1650W

Water Supply

Water input

Connect to the water pipe directly

Water pressure

0.08

 

MPa - 0.75

 

MPa (0.8

 

kgt/cm² - 7.5

 

kgt/cm²)

Wash device

Rear wash water volume

0.5

 

L/min - 0.9

 

L/min

Front wash water volume

0.5

 

L/min - 0.9

 

L/min

Tank volume

1

 

L

Temperature

Room temp./Low 33°C/Medium 37°C/High 40°C

Heating power

1600W

Safety device

Floating switch / Temperature fuse / Water level sensor

Heated seat

Temperature

Room temp./Low 30°C/Medium 35°C/High 40°C

Heating power

40W

Safety device

Temperature fuse

Warm air 

dryer

Temperature

Room temp./Low 35°C/Medium 40°C/High 45°C

Heating power

200W

Safety device

Temperature fuse

Other safety device

Earth leakage protector

Power cord length

1.5

 

m

Net weight

46

 

kg

NOTE: 

1.  Please stop the water supply if the power suddenly turns off in the process of using. The product will 

run self-checking system and recover after power turns back on.

2.  Please use our special angle valve and other accessories.

Phenomenon

Inspection Method

Solution

Fail to run

Power failure or forget to 

switch on

Confirm the power is on 
Reconnect the power

The nozzle does 

not spray or the 

water does not 

flow smoothly

Water supply failure or water 

tap shut off

Check the water supply and turn on the valve

Filter mesh is jammed

Check the filter mesh 

Water outlet is jammed by 

limescale

Clean the nozzle with toothbrush

Water leakage

Connection parts not tight

Tighten connection

Low temperature 

for water or seat

Temperature not set 

Reset the temperature

Summary of Contents for Smart Toilet

Page 1: ...Smart Toilet USER MANUAL CLEAN COMFORT HYGIENE ...

Page 2: ...t use wet hand to touch power plug which may lead to electric shock Please do not spray water or cleaning agent on the product or power plug which may lead to electric shock and malfunction 1 As an electric appliance the product should not be installed too close to splashing water or in very humid conditions 2 The socket load should be 1300W and up 3 The battery for the remote control will be 3 x ...

Page 3: ...ay lead to fire Dismantling repair and alteration of the product is forbidden Do not force the toilet seat lid to close Disconnect the power plug during thunderstorms Ensure the plug is grounded Beware of low temperature burn if seated on toilet too long Disconnect the plug if there is abnormal smell or sound Do not lean on the seat cover Do not spray water or cleaning agent on the product and pow...

Page 4: ...o will front wash 30 seconds move wash 30 seconds and drying 3 minutes then stop Bidet Moving wash Same operation as posterior moving wash button the only difference is the washing position This is designed for female users Dryer Press this button to activate drying function Will stop automatically after 5 minutes or when you stand Press Dryer temp button to adjust dryer temperature 4 levels to ch...

Page 5: ...pen they will close automatically after 90 seconds Flush automatically when you stand When nobody is seated on toilet press Stop Flush button to flush When there is no electricity press the side button to flush When seated on the toilet press any wash button nozzle will clean itself for 3 seconds then come out to wash when you stand nozzle will clean itself again for 3 seconds Automatic deodorizat...

Page 6: ... 7 5 kg 5 After flange installed put the toilet on the ground and make sure the cross central line and the sewage are aligned Then compress slowly until tight 7 Coat anti mildew sealants on the circle of the toilet with contact to the ground 8 After sealants are solid plug in the power slowly open the angle valve Control the water pressure under 7 5 kg and check the connection is well sealed 6 Ins...

Page 7: ...flush Pair remote controller when seated on the toilet STEP 1 Keep pressing side button for 5 seconds until you hear BEEP the LED display will blink at the same time now the toilet is waiting to pair STEP 2 Press any button on the remote controller will hear BEEP and LED display will stop blinking pair finished The remote control should already be paired Only need to pair if setting up a new remot...

Page 8: ... fuse Other safety device Earth leakage protector Power cord length 1 5 m Net weight 46 kg NOTE 1 Please stop the water supply if the power suddenly turns off in the process of using The product will run self checking system and recover after power turns back on 2 Please use our special angle valve and other accessories Phenomenon Inspection Method Solution Fail to run Power failure or forget to s...

Reviews: