-115-
PC.48
Running time of simple PLC
reference 15
0.0s(h)~6553.5s(h)
0.0s(h)
☆
PC.49
Acceleration/deceleration
time of simple PLC
reference 15
0~3
0
☆
PC.50
Time unit of simple PLC
running
s(s)
0
0
☆
h(hour)
1
PC.51
Reference 0 source
PC.00 setting
0
0
☆
AI1
1
AI2
2
AI3( keyboard potentiometer)
3
Pulse setting
4
PID
5
Set by preset frequency (P0.08),
modified via terminal UP/DOW N
6
It determines the setting channel of reference 0. You can perform convenient switchover between
the setting channels. When multi-reference or simple PLC is used as frequency source, the switchover
between two frequency sources can be realized easily.