-117-
PD.02
This device address
1-247, 0 is master station address
1
☆
PD.03
Response delay
0ms-20ms
2
☆
PD.04
Communication
over-time
0.0(invlaid), 0.1s-60.0s
0.0
☆
PD.05
Data transfer format
One’s place MODBUS
30
☆
Non-standard MODBUS protocol
0
Standard MODBUS protocol
1
Ten’s place
Profibus-DP
PPO1 format
0
PPO2format
1
PPO3format
2
PPO5format
3
PD.06
Current resolution
0.01A
0
0
☆
0.1A
1
4.16 PE group: reserved
4.17 Function code management:PP.00-PP.04
Code
Description
Setting range
Default
Restric
tions
PP.00
User password
0~65535
0
☆
If it is set to any non-zero number, the password protection function is enabled. After a
password has been set and taken effect, you must enter the correct password in order to enter the
menu. If the entered password is incorrect you cannot view or modify parameters.
If PP.00 is set to 00000, the previously set user password is cleared, and the password
protection function is disabled.
PP.01
Parameter initialization
No operation
0
0
★
Restore factory settings except
motorparameters
1
Clear records
2
Restore factory settings including
motor parameters
3
Backup current user parameters to
control board memory
4
Backup current user parameters to
keyboard memory 1
5
Backup current user parameters to
keyboard memory2
6
Summary of Contents for DLB1-0D40S2G
Page 11: ...11 Graph 1 722 30KW product outline dimensions Graph 1 837 55KW product outline dimensions...
Page 12: ...12 Graph 1 875 110KW product outline dimensions Graph 1 9 132 160KW product outline dimensions...
Page 14: ...14 2 Wirings 2 1 Standard wiring diagrams Graph 2 8 0 4 18 5KW inverter wiring diagram...
Page 15: ...15 Graph 2 922 400KW inverter wiring diagram...
Page 159: ...159...