-26-
Motor parameter auto-tuning
Procedures:
1)
Set P0.02=0 (operation panel as command source channel)
2)
Input motor actual parameters:
Motor selection
Parameters
Motor1
P1.00:motor type selection P1.01:rated power
P1.02:rated voltageP1.03:rated current
P1.04:rated frequencyP1.05:rated speed
3)
If (asynchronous) motor can separate from load, set P1.37=2 (asynchronous motor complete
auto-tuning) and press RUN key. The inverter will automatically calculate parameters below:
Motor selection
Parameters
Motor1
P1.06:asynchronous motor stator resistor
P1.07:asynchronous motor rotorresistor
P1.08:asynchronous motor leakage
inductanceP1.09:asynchronous motor mutual inductance
P1.10:asynchronous motor no load current
4) If (asynchronous) motor cannot separate from load, set P1.37=1 and press RUN key.
Finish auto-tuning.
3.3
JOG
DLB1 series default setting value
Code
Default setting
value
P0.01
0
Sensorless vector control
(
SVC
)
P0.02
0
Operation panel command channel
(
LED OFF
)
P0.03
0
Keyboard setting frequency(P0.08, UP/DOW N can
edit, not retentive at power failure)
After correctly set motor parameter P1.00-P1.05 and auto-tuning, user can control motor operation using
keyboard.
Summary of Contents for DLB1-0D40S2G
Page 11: ...11 Graph 1 722 30KW product outline dimensions Graph 1 837 55KW product outline dimensions...
Page 12: ...12 Graph 1 875 110KW product outline dimensions Graph 1 9 132 160KW product outline dimensions...
Page 14: ...14 2 Wirings 2 1 Standard wiring diagrams Graph 2 8 0 4 18 5KW inverter wiring diagram...
Page 15: ...15 Graph 2 922 400KW inverter wiring diagram...
Page 159: ...159...