-55-
4.6 Input terminals:P4.00-P4.39
The DLB1 provides six DI terminals (DI5 can be used for high-speed pulse input) and
three analog input (AI) terminals. The optional extension card provides another four DI
terminals (DI7 to DI10) and an AI terminal (AI3x).
Code
Description
Setting range
Defa
ult
Restri
ctions
P4.00
DI1 function selection
0~59
1
★
P4.01
DI2 function selection
0~59
4
★
P4.02
DI3 function selection
0~59
9
★
P4.03
DI4 function selection
0~59
12
★
P4.04
DI5 function selection
0~59
13
★
P4.05
DI6 function selection
0~59
2
★
P4.06
DI7 function selection
0~59
12
★
P4.07
DI8 function selection
0~59
13
★
P4.08
DI9 function selection
0~59
14
★
P4.09
DI10 function selection
0~59
15
★
The following table lists the functions available for the DI terminals.
Value
Function
Description
0
No function
Set 0 for reserved terminals to avoid malfunction.
1
Forward RUN (FWD)
The terminal is used to control forward or reverse RUN of
the Inverter.
2
Reverse RUN (REV)
3
Three-line control
The terminal determines three-line control of the Inverter.
For details, see the description of P4.11.
4
Forward JOG (FJOG)
FJOG indicates forward JOG running, while RJOG indicates
reverse JOG running. The JOG frequency, acceleration time
and deceleration time are described respectively in P8.00,
P8.01 and P8.02.
5
Reverse JOG
(RJOG)
6
Terminal UP
If the frequency is determined by external terminals, the
terminals with the two functions are used as increment and
decrement commands for frequency modification. When the
frequency source is digital setting, they are used to adjust
the frequency.
7
Terminal DOW N
8
Coast to stop
The Inverter blocks its output, the motor coasts to rest and is
not controlled by the Inverter. It is the same as coast to stop
described in P6.10.
9
Fault reset (RESET)
The terminal is used for fault reset function, the same as the
function of RESET key on the operation panel. Remote fault
reset is implemented by this function.
Summary of Contents for DLB1-0D40S2G
Page 11: ...11 Graph 1 722 30KW product outline dimensions Graph 1 837 55KW product outline dimensions...
Page 12: ...12 Graph 1 875 110KW product outline dimensions Graph 1 9 132 160KW product outline dimensions...
Page 14: ...14 2 Wirings 2 1 Standard wiring diagrams Graph 2 8 0 4 18 5KW inverter wiring diagram...
Page 15: ...15 Graph 2 922 400KW inverter wiring diagram...
Page 159: ...159...