-69-
5
Zero-speed running (no
output at stop)
If the Inverter runs with the output
frequency of 0, the terminal becomes ON. If
the Inverter is in the stop state, the terminal
becomes OFF.
6
Motor overload pre-warning
The Inverter judges whether the motor load
exceeds the overload pre-warning
threshold before performing the protection
action. If the pre-warning threshold is
exceeded, the terminal becomes ON. For
motor overload parameters, see the
descriptions of P9.00 to P9.02.
7
Inverter overload prewarning
The terminal becomes ON 10s before the
Inverter overload protection action is
performed.
8
Set count value reached
The terminal becomes ON when the count
value reaches the value set in PB.08.
9
Designated count value
reached
The terminal becomes ON when the count
value reaches the value set in PB.09.
10
Length reached
The terminal becomes ON when the
detected actual length exceeds the value
set in PB.05.
11
PLC cycle complete
When simple PLC completes one cycle, the
terminal outputs a pulse signal with width of
250 ms.
12
Accumulative running time
reached
If the accumulative running time of the
Inverter exceeds the time set in P8.17, the
terminal becomes ON.
13
Frequency limited
If the set frequency exceeds the frequency
upper limit or lower limit and the output
frequency of the Inverter reaches the upper
limit or lower limit, the terminal becomes
ON.
14
Torque limited
In speed control mode, if the output torque
reaches the torque limit, the Inverter enters
the stall protection state and meanwhile the
terminal becomes ON.
15
Ready for RUN
If the Inverter main circuit and control circuit
become stable, and the Inverter detects no
fault and is ready for RUN, the terminal
becomes ON.
16
AI1 larger than AI2
When the input of AI1 is larger than the
input of AI2, the terminal becomes ON.
Summary of Contents for DLB1-0D40S2G
Page 11: ...11 Graph 1 722 30KW product outline dimensions Graph 1 837 55KW product outline dimensions...
Page 12: ...12 Graph 1 875 110KW product outline dimensions Graph 1 9 132 160KW product outline dimensions...
Page 14: ...14 2 Wirings 2 1 Standard wiring diagrams Graph 2 8 0 4 18 5KW inverter wiring diagram...
Page 15: ...15 Graph 2 922 400KW inverter wiring diagram...
Page 159: ...159...