4.9 Operation panel and display:P7.00-P7.14
Code
Description
Setting range
Def
ault
Restri
ctions
P7.01
DIR/JOG function
DIR/JOG disabled
0
0
★
Switchover between operation panel
control and remote command control
(terminal or communication)
1
Switchover between forward rotation
and reverse rotation
2
Forward JOG
3
Reverse JOG
4
DIR/JOG key is a multifunctional key. You can set the function of the DIR/JOG key by using this
parameter. You can perform switchover by using this key both in stop or running state.
•
0: DIR/JOG key disabled This key is disabled.
•
1: Switchover between operation panel control and remote command control (terminal or
communication)
You can perform switchover from the current command source to the operation panel control
(local operation). If the current command source is operation panel control, this key is invalid.
•
2: Switchover between forward rotation and reverse rotation
You can change the direction of the frequency reference by using the DIR/JOG key. It is valid
only when the current command source is operation panel control.
•
3: Forward JOG
You can perform forward JOG (FJOG) by using the DIR/JOG key.
•
4: Reverse JOG
You can perform reverse JOG (FJOG) by using the DIR/JOG key.
P7.02
STOP/RESET
STOP/RESET key enabled only in
operation panel control
0
1
☆
STOP/RESET key enabled in any
operation mode
1
P7.03
LED display running
parameters 1
0000~FFFF
1F
☆
Summary of Contents for DLB1-0D40S2G
Page 11: ...11 Graph 1 722 30KW product outline dimensions Graph 1 837 55KW product outline dimensions...
Page 12: ...12 Graph 1 875 110KW product outline dimensions Graph 1 9 132 160KW product outline dimensions...
Page 14: ...14 2 Wirings 2 1 Standard wiring diagrams Graph 2 8 0 4 18 5KW inverter wiring diagram...
Page 15: ...15 Graph 2 922 400KW inverter wiring diagram...
Page 159: ...159...