LGCN
8
2) Remove the samples and put the load on, the scale begins to count.
3) Press key
CE
to return to the weighing mode.
ACAI
Automatic Counting Accuracy Improvement (ACAI) results in a more accurate count by
increasing the reference weight without the need to count additional parts. A higher reference
weight is important when there is a risk of inconsistent piece weights or if the reference
weight is close to the minimum. ACAI uses an initial averaging unit weight to count additional
pieces that are placed on the scale .the scale gives a beep as the new higher reference
weight is used to recalculate the averaging unit weight. The process can be repeated as long
as the additional weight is less than the previous reference weight . Once this limit is
exceeded ACAI is turned off.
6. Calibration
1) For best result, calibrate the scale on a regular basis. Temperature change, geographic
gravity variation, altitude change and abuse are reasons why a scale may need recalibration.
2) Here we take LGCN-1530 as an example.
6-1 Single Point Calibration
1) Switch on the power, press and hold key
SMPL
while pressing key
.
2) Input 11 with numeric keys.
3) Again press key
SMPL
to enter the zero point
calibration modes, with “
” flashing.
4) Wait till “
” stop flashing, press key
SMPL
, then
Key in the calibration value with the numeric keys .(unit
is g)
Summary of Contents for LGCN-3075