1 0 9 7 2 0
1 0 9 7 2 0
Plumbers' Putty or Caulking
Adjustable Wrench
Teflon Tape
Phillips Screwdriver
Channel Locks
TOOLS REQUIRED
Tubing Cutter
Regular Screwdriver
FINISHED WALL
BOTTOM OF
TUB
OR SHOWER
STALL
48" TO 54"
OPTIONAL
ROUGHING-IN DIMENSIONS
7-7/8" D.
SHW
TUB
By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT
SAFETY STOP (1) reduces risk of accidental scalding. To set the maximum hot water temperature of your faucet, all
you need to do is adjust the setting on the HOT LIMIT SAFETY STOP (1).
15
13
11
97
531
0
15
1
3
1
1
9
7
5
3
1
15
1
3
1
1
9
7
5
3
1
2
COLDER
(Larger Numbers)
0 1 3 5 7 9 11 13 15
HOTTER
(Smaller Numbers)
0 1 3 5 7 9 11 13 15
Turn CARTRIDGE STEM (2) to the OFF position (coldest setting) before making adjustment to HOT LIMIT STOP (1). Use
a flat blade screwdriver to pry free the HOT LIMIT SAFETY STOP (1). Pull forward and rotate counterclockwise one number
to limit hot water temperature. Use ARROW (3) on CARTRIDGE (4) and NUMBERS (5) on HOT LIMIT STOP (1) for indication.
1
5
1
5
4
1
4
3
3
2
2
GREASE
O-RING
1
INSTALL TRIM
Push CAP (1) onto VALVE CARTRIDGE (2).
Mount ESCUTCHEON HOLDER (3) with gasket and the ESCUTCHEON
(4) to valve body and secure with SCREWS (5).
Push the COVER (6) as shown over the CAP (1) and align prongs on
COVER (6) with screw holes in ESCUTCHEON (4).
Important! Make sure COVER (6) snaps over the SCREWS (5).
Push ADAPTER (7) over CARTRIDGE STEM (8).
Push ESCUTCHEON (9) onto ADAPTER (7).
Mount CROSS HANDLE (10) or LEVER HANDLE (11) and secure with
WASHER and SCREW (12).
Cover with CAP (13).
6
7
3
11
13
12
1
10
5
2
4
8
9
CAUTION: Protect finish on SHOWER ARM
and SHOWER HEAD when installing.
ADJUST HOT LIMIT STOP
TEST INSTALLED FITTING
3
Turn VALVE "off".
With HANDLE (1) in "off" position, turn on water supplies and check all
connections for leaks.
Operate HANDLE (1) and flush water lines thoroughly. Check the function for
proper operation.
4
BACK TO BACK INSTALLATION
(SEE ILLUSTRATION STEP 5 FOR REFERENCE)
Remove Handle and Trim from Valve. See step 1 for reference.
Remove PRESSURE BALANCE UNIT (5). Rotate PRESSURE BALANCE UNIT (5) 180˚ so that the inlets face up and the
large outlet port faces down.
Push PRESSURE BALANCE UNIT (5) in casting make sure inlets line up with holes in bottom of casting. Top
flange should butt up against top of casting.
Reassemble FIXATION RING (4) and CARTRIDGE (1).
For reference