5
3
WATER SUPPLY CONNECTIONS
Connect water supply to VALVE BODIES
(1)
with 1/2" IPS
FLEXIBLE SUPPLIES
(3)
or 3/8" O.D. BULL-NOSE RISERS
(4)
.
Use wrench to tighten connections.
Do not over tighten. Be careful not to kink copper supply when
bending. Use tubing cutter to cut to proper length.
1
4
FERRULE
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE
PURCHASED SEPARATELY.
COUPLING
NUT
H 9 6 5 1 2 7 B
Widespread Lavatory Faucets
APPLY SEALANT
OR TEFLON TAPE
4
A FOAM SEAL
(1)
is installed on underside of FLANGE
(2)
. (Plumbers
Putty may be used in place of FOAM SEAL
(1)
if desired.)
Apply sealant or Teflon tape to threads of TAILPIECE
(10)
and
thread into DRAIN BODY
(7)
making a water tight seal.
Drop FLANGE
(2)
into LAVATORY DRAIN
(3)
. From below assemble
RUBBER GASKET
(4)
, PLASTIC WASHER
(5)
and LOCK NUT
(6)
onto
DRAIN FLANGE
(2)
. Do not tighten fully.
INSTALL POP-UP DRAIN
FIG. 4a
FIG. 4b
FIG. 4c
FIG. 4c
FIG. 4a
FIG. 4b
1
4
3
2
5
6
7
8
6
9
2
Adjust STOPPER
(13)
height by repositioning POP-UP ROD
(16)
in SWIVEL
(15)
and tightening SET SCREW
(18)
.
Assemble POP-UP SWIVEL
(15)
to PIVOT ROD
(11)
but do not tighten.
Drop POP-UP ROD
(16)
through other hole in POP-UP SWIVEL
(15)
and
tighten SET SCREW
(17)
.
Assemble PIVOT ROD
(11)
, WASHER (20) and PIVOT NUT
(12)
as shown.
Install CONCAVE WASHER
(19)
into PIVOT ROD OPENING
(9)
if not preinstalled.
Hand tighten PIVOT NUT
(12)
. Drop STOPPER
(13)
into drain.
(To vandal proof drain rotate STOPPER
(13)
so PIVOT ROD (11) goes
through EYE
(14)
of STOPPER
(13)
. Make connection to "P" TRAP.
Inspect inside DRAIN BODY
(7)
that SEAL
(8)
is installed. Thread
DRAIN BODY
(7)
tight against FLANGE
(2)
to make a water tight seal.
10
9
7
6
16
15
17
18
2
10
14
13
12
The PIVOT ROD OPENING
(9)
in DRAIN BODY
(7)
should face the rear
of the lavatory. Tighten LOCK NUT
(6)
on FLANGE
(2)
to make a water
tight connection with channel locks. Do not over tighten.
19
20
11
8
12
13
14
9
11
10
COLD
HOT
1-3/4'' MAX.
2
3
INSTALL VALVE BODIES
"O" RING
Thread LOCKNUT
(8)
to bottom of VALVE BODY
(2)
. Make sure
FIBER WASHER
(9)
and RUBBER WASHER
(10)
are installed.
Insert VALVE BODY
(2)
through mounting hole from underside
of lavatory or mounting surface.
Note: VALVE BODY marked with Red Dot is installed in the left mtg.
hole, VALVE BODY marked with Blue Dot in the right when facing
front of fitting. Maximum mounting surface thickness is 1-3/4".
From top install SPACER
(7)
onto VALVE BODY
(2)
. Thread
MOUNTING RING
(6)
on VALVE BODY
(2)
until seated tightly against
SPACER
(7)
. Set VALVE BODIES
(2)
so that their outlets are facing
toward SPOUT TEE
(11)
and then tighten LOCKNUT
(8)
using 35mm
or adjustable wrench.
Tighten COUPLING NUTS
(13)
of SUPPLY HOSES
(14)
to
INLET
(12)
, making water tight connection.
Important: Loop
SUPPLY HOSES
(14)
as illustrated so they do not kink.
6
1
3
4
7
5
"O" RING
1A
INSTALL HANDLES (LEVER and CROSS)
Turn VALVE BODIES
(2)
to off position. Align HANDLES as shown or
as desired and install HANDLE ASSEMBLY
(1, 1A)
onto VALVE
STEM
(5)
. Thread HANDLE BASE
(3)
onto VALVE BODY
(2)
until
seated tightly against mounting surface.