background image

1 0 9 4 3 4

1 0 9 4 3 4

Roman Tub Fillers

1

SPOUT ASSEMBLY

2

TEE AND HOSE ASSEMBLY

Insert SPOUT SHANK (1) through center hole of tub deck or mounting surface. Make sure RUBBER WASHER (2) is 
properly positioned into SPOUT ESCUTCHEON BASE (3).

Assemble RUBBER WASHER (4), FIBER WASHER (5) and LOCKNUT (6) onto threads of SPOUT SHANK (1)
from underside of tub deck or mounting surface.

Push one RING WASHER (1) and one 0-RING (2) onto end
of SPOUT SHANK (3).

Slide the TEE (4) onto SPOUT SHANK (3) until it makes
contact with the 0-RING (2). Push the other 0-RING (2)
and RING WASHER (1) onto the SPOUT SHANK (3).
Make sure both 0-RINGS (2) are seated into grooves
of TEE (4).

Thread LOCK NUT (5) onto SHANK (3). Rotate TEE (4)
about 10 degrees from center and tighten securely.

Insert FIBER WASHERS (6) into COUPLING NUTS (7) of
SUPPLY HOSES (8) and tighten.

Align SPOUT (8) and tighten LOCKNUT (6).

Note: All deck mounted Roman tub sets must be installed with the tub spout outlet at least two (2) inches above
the flood level rim of the tub. See Figure 1a.

1

4

5

6

3

Turn off hot and cold water
supplies before beginning.

CAUTION

1-3/4" MAX.

2

8

2

2

1

1

3

4

GROOVE IN TEE

GROOVE IN TEE

10˚

FRONT

Figure 1a

DECK MOUNT

BATH

RIM

BATH

RIM

TWO (2) INCHES

MINIMUM

TUB MOUNT

TWO (2) INCHES

MINIMUM

ROUGHING-IN
DIMENSIONS

Plumbers' Putty or Caulking

Adjustable Wrench

Phillips Screwdriver

Channel Locks

TOOLS REQUIRED

Tubing Cutter

Regular Screwdriver

Basin Wrench

3/4"NPT

INLETS

NOTE : BORE SIZE 1-3/8"

2-3/4" D.

1-3/8" D.

6-7/16"

9"

2-13/16" D.

30º

2" MAX.

3

INSTALL VALVE BODIES AND HANDLES

INSTALL VALVES

REMOVE HANDLES

1-1/4'' MAX.

Thread LOCKNUT (10) to bottom of VALVE BODY (1). Make sure FIBER
WASHER (11) and RUBBER WASHER (12) are installed. Insert VALVE
BODY (1) through mounting hole from underside of SINK or mounting
surface.

Note: If HANDLES ASSEMBLIES are installed on VALVE BODIES (1) they must be
removed to install VALVE BODIES (1) from under lavatory or mounting surface.

To remove CRYSTAL KNOB HANDLE (2): Unthread INDEX CAP (3) and remove
HANDLE SCREW (4). Pull off CRYSTAL KNOB HANDLE (2) and unthread HANDLE
BASE (5). Unthread ESCUTCHEON (6).

To remove LEVER HANDLES (2): Loosen SET SCREW (7) with Hex Wrench
provided with faucet. Pull LEVER HANDLE (8, 9) off and unthread HANDLE BASE (5)
and ESCUTCHEON (6).

Insert FIBER WASHERS (13) into COUPLING NUTS (14) of SUPPLY HOSES (15) and
tighten making water tight connection. 

Important: Loop SUPPLY HOSES (15) as

shown so they do not kink. 

3
4

2

5

6

10

1

13 14

15

11

18

16

12

JADO

INSTALL HANDLES

COLD

HOT

8

9

7

17

17

7

Hex wench

supplied

Seal

Note: VALVE BODY marked Hot is installed in the left Mtg. hole,
VALVE BODY marked Cold in the right when facing front of fitting.
Maximum mounting surface thickness is 1-1/4".

For Crystal handles:

 With VALVE in off position align CRYSTAL HANDLE (2) and install

onto VALVE STEM (18). Install HANDLE SCREW (4) and tighten. Install INDEX CAP (3). 

For Lever Handles:

 Install FRICTION WASHER (17) onto base of LEVER HANDLE (8, 9).

With VALVE in off position align LEVER HANDLE (8, 9) as shown or as desired. Install
LEVER HANDLE (8, 9) onto VALVE STEM (18) and tighten SET SCREW (7) with HEX
WRENCH supplied. 

Thread ESCUTCHEON (6) with seal onto VALVE BODY (1). Thread HANDLE
BASE (5) onto VALVE BODY (1) until snug against internal stop. Thread
ESCUTCHEON (6) counter-clockwise until seated against HANDLE BASE (5).
Set VALVE BODIES (1) so that their outlets are facing toward SPOUT TEE
(16) and then tighten LOCKNUT (10) using wrench.

6" TO 12" 

Reviews: