background image

 

OPERATION AND MAINTENANCE MANUAL 

12-2015 

 

8

3.3 STORAGE 

 

Store the gate valves in sheltered rooms. 

 

3.4 TRANSPORT 

 
 

Transport the gate valves on sheltered vehicles. 
Never suspend the valve by its drive actuator when handling. 

 
 

 

 

It is recommended use belt slings as shown in the diagram above 

 for handling and installation of the gate valves from DN50 to DN200. 

 

4 ASSEMBLY AND INSTALLATION 

 

4.1 ASSEMBLY GUIDELINES 

 
 

The Type 2109 and 2909 metal seated gland packed wedge gate valves can be installed in underground 

or overground pipelines both in horizontal or vertical orientation. The listed products are suitable for joining with 
the flanged ends of pipelines with the size equal to that of the valve flanges. Note that the system must not expose 
the  (gate)  valve  to  bending  or  tensile  stress  from  loading  with  the  weight  of  unsupported  pipeline  sections. 
Assemble with consideration to pressure and temperature compensation of the pipeline. The valve assembled and 

Summary of Contents for 2109

Page 1: ...d for use by President of Factory JAFAR S A Failure to comply with the guidelines and instructions in this Operation and Maintenance Manual releases the manufacturer from all obligations liability and...

Page 2: ...HE VALVE DESIGN 3 2 2 MATERIALS 4 2 3 DIMENSIONS 5 2 4 REFERENCE STANDARDS 6 2 5 ORDERING INFORMATION 7 2 7 MARKINGS 7 3 PROTECTION STORAGE TRANSPORT 7 3 1 PROTECTIVE COATINGS 7 3 2 PACKAGING 7 3 3 ST...

Page 3: ...teel rings Nominal diameter dimension range DN40 to DN600 mm Maximum medium flow rate liquid max 4 m s gas max 30 m s The driving torque at opening start and closing end is as listed below DN mm 40 50...

Page 4: ...aterial Reference standard 1 Body Spheroidal cast iron EN GJS 400 15 EN GJS 500 7 PN EN 1563 2012 2 Cover Spheroidal cast iron EN GJS 400 15 EN GJS 500 7 PN EN 1563 2012 3 Wedge Spheroidal cast iron E...

Page 5: ...OPERATION AND MAINTENANCE MANUAL 12 2015 5 2 3 DIMENSIONS Drive ready 2109 With electric drive actuator 2909...

Page 6: ...flanges PN EN19 2005 Industrial valves Marking of metallic valves PN EN 12266 1 2012 Industrial valves Testing of metallic valves Pressure tests test procedures and acceptance criteria Mandatory requ...

Page 7: ...following standards PN EN 19 2005 PN EN 1171 2007 The gate valve bodies feature markings on the front and back walls of the body chamber The marking contains the following data valve type defined by...

Page 8: ...ION 4 1 ASSEMBLY GUIDELINES The Type 2109 and 2909 metal seated gland packed wedge gate valves can be installed in underground or overground pipelines both in horizontal or vertical orientation The li...

Page 9: ...OPERATION The gate valve shall be operated according to all relevant requirements for cut off valves i e either in fully open or fully closed positions Leaving the gate valve partially opened or close...

Page 10: ...ANUAL 12 2015 10 The product assembled installed and operated in compliance with this Manual is covered by a commercial warranty from the manufacturer The conditions and period of the warranty is spec...

Reviews: