Installation
Item no. 10406064, Revision 03
31 ( 48 )
8.3.2
Setting the cooling
Ü
Observe the following values for liquid cooling:
Hose diameter (*)
Min. DN 5.5
Feed temperature
Min. 20°C
Volumetric flow
Min. 1.5 l/min
Return temperature
Max. 40°C
(*) Use cooling hoses that are impermeable to UV light.
8.4
Hydraulic tool change
Ü
Use only hydraulic oil with the following properties:
DIN 51524
ISO 6743
HLP 46
8.5
Compressed air
8.5.1
Air purity classes (ISO 8573-1)
Solid impurities
Class 3
Filter grade at least 5 µm for solids
Water content
Class 4
Max. pressure dew point +3 °C
Total oil content
Class 3
Max. oil content 1 mg/m
3