Technical description
Item no. 10406166, Revision 03
12 ( 48 )
5
Technical description
5.1
Connections of HF spindle
3b
8
2
2
1c
3a
1b
1a
7
12
11 4
1a
Electrical connection for: motor phases
1b
Electrical connection for: Tool taper monitoring, PTC, KTY
1c
Electrical connection for: Vector control
2
Cooling water
G 1/4"
3a
Sealing air (front)
G 1/8"
3b
Sealing air (rear)
M5
4
Taper cleaning
G 1/4"
7
Hydraulic system for tool change (cylinder forward)
M10x1
8
Hydraulic system for tool change (cylinder back)
M10x1
11
Internal coolant supply
G 1/4"
12
Leakage
G 1/4"