ADwin-Pro II
Hardware, manual Dec. 2018
7
ADwin-Pro II-BM
ADwin-Pro II-BM
ADwin
4.3
ADwin-Pro II-BM
Pro II "backmounted"
with 15 slots
In the version "backmounted" of the standard enclosure, the modules are
plugged-in at the rear of the enclosure.
Fig. 5 – Enclosure of
ADwin-Pro II-BM
(rear panel)
The system fuse is located in a slot in the power supply unit above the female
connector for the power supply cable (rear of the enclosure).
At the rear of the enclosure, above the power supply connector you will find a
label with the revision number:
Number of Slots
16
Main dimensions (l x w x h)
Slot area (w x h)
336mm × 447.5mm × 146mm (incl. feet)
84 HP × 3 U
Power supply unit
100V…240V AC at 50/60Hz
switching-mode power supply
upper power limit >70W
Fuse
5A, slow-blow fuse
Fig. 6 – Enclosure of the
ADwin-Pro II
-BM: Specification
Revision
Release
Previous versions
E1
Jun. 2006
ADwin-Pro II
: New enclosure design and new back
plane with Pro I and Pro II bus.
6
3
4
5
1
2
POWER
ON
230V
CPU-T
ADwin-
ST
AC
ET
HERNET
DIG I/O