ADwin-Pro II
Hardware, manual Dec. 2018
191
Pro II: Extension and Interface Modules
Pro II-FlexRay-2 Rev. E
ADwin
If an interface runs as physical end of a FlexRay bus, the bus bus must be ter-
minated at this interface with the appropriate DIP switch (see fig. 161); the
channels A and B can be terminated separately. Since both channels are run
differential, you always have to switch both (!) DIP switches for each channel
to the right for termination.
If the FlexRay module is not located at the end of the bus you may not termi-
nate the interface.
Both FlexRay interfaces can be combined to a startable FlexRay cluster via
DIP swithces. For combination of the channels A and B you always have to
switch both (!) DIP switches for each channel upwards (see fig. 161).
Fig. 161 – Pro II-FlexRay-2 Rev. E: PCB and front panel
Module Revisions
The differences between the revisions are described below:
Programming
The module is comfortably programmed with
ADbasic
instructions. The
instructions are described in
ADbasic
online help and in the Pro II Software
manual.
The include file
ADwinPro_All.inc
contains instructions for the following
functions:
Revision
Output
date
Previous changes
E1
08 / 2009 First version
Area
Instructions
Initialize a FlexRay interface
P2_FlexRay_Init
Reset a FlexRay controller
P2_FlexRay_Reset
Query interface version
P2_FlexRay_Get_Version
Set and read controller register
P2_FlexRay_Read_Word
P2_FlexRay_Write_Word
Set module LED
P2_Check_LED
P2_Set_LED
P2_FlexRay_Set_LED
FlexRay-2
CHANNEL
1
2
A
B
A
B
19CAN1003
LM3940-3.3
ADM
706
XC3S400
XILINX
®
LT
525
XCF04S
LT1764
LT1764
24512
2995
XCF02S
LM92
CBTD16210DGG
CBTD16210DGG
CBTD16210DGG
CBTD16210DGG
OFF ON
B
Connector 1 & 2:
CONNECTED
DISCONNECTED
A
B
A
B
A
OFF ON
OFF ON
OFF ON
Termination
Termination
DIP switch for
bus termination
D I P s w i t c h f o r
combination
1
2