background image

Declaration of Incorporation

Item no. 10408018, Revision 03

43 ( 44 )

15

Declaration of Incorporation

Under the EC Machinery Directive

The safety instructions of the
product documentation sup-
plied must be observed.

Nakanishi Jaeger GmbH

SF-Elektromaschinenbau

Siemensstr. 8

D-61239 Ober-Mörlen

Tel. +49 (0) 60029123 -0

hereby declare that the product,

Product

High Frequency Spindle

Type

Z120-H824.06 K1W2V

Serial no.

See last page of manual

as far as possible from the supplied, complies with the essential requirements
of the Machinery Directive 2006/42/EC.

Sections of the Machinery Directive have been applied: 1.1.1; 1.1.2; 1.1.5; 1.3.2;
1.3.4; 1.5.1; 1.5.2; 1.5.4; 1.5.5; 1.5.6; 1.5.8; 1.5.9; 1.6.4; 1.6.5; 1.7.1; 1.7.1.1; 1.7.2;
1.7.3; 1.7.4;

The  incomplete  machinery  in  its  standard  design  complies  furthermore  with
the following applicable regulations:

Applicable harmonized standards

DIN EN ISO 12100

Safety of machines

The machinery is incomplete and must not be put into service until the ma-
chinery  into  which  it  is  to  be  incorporated  has  been  declared  in  conformity
with the provisions of the Machinery Directive 2006/42/EC and any other ap-
plicable regulations.

We at Nakanishi Jaeger GmbH agree to submit the special documents for in-
complete machines to national authorities upon request.

The special technical documentation referred to in Annex VII, Part B, belong-
ing to the machine has been created.

Person who is authorized to compile the documents listed in Annex VII, Part B:

Nakanishi Jaeger GmbH

Ober-Mörlen, 01.09.2023

Summary of Contents for Z120-H824.06 K1W2V

Page 1: ...Manual Z120 H824 06 K1W2V High Frequency Spindle Pneumatic taper change ...

Page 2: ...lopment we reserve the right to make technical modifications and variations from the exact design described in the manual The text in this manual has been compiled with the utmost care However Nakanishi Jaeger GmbH cannot assume any legal responsibility or liability of any kind for incorrect information and any consequences thereof Translations and reproductions including of extracts are prohibite...

Page 3: ...ifications 22 6 7 Air borne noise emissions 23 7 Operating location 23 8 Installation 24 8 1 Installing the HF spindle 24 8 2 Diameter of media supply line 25 8 3 Cooling water 25 8 3 1 Quality of cooling water 25 8 3 2 Setting the cooling 25 8 4 Compressed air 26 8 4 1 Air purity classes ISO 8573 1 26 8 4 2 Setting the sealing air 26 8 4 3 Setting values 27 9 Commissioning 28 9 1 Running in sched...

Page 4: ...18 Revision 03 4 44 Contents Translation of the original manual 13 1 Disposal and environmental protection 38 14 Service and repairs 39 14 1 Service partners 39 14 2 Malfunctions 40 15 Declaration of Incorporation 43 ...

Page 5: ...tion of the man ual carefully again 1 2 Explanation of symbols used To enable quick classification of information this manual uses visual aids in the form of symbols and text markings Notes are marked with a signal word and a colored box DANGER Dangerous situation Results in serious injury or death u Measure to avert the danger WARNING Dangerous situation May result in serious injury or death u Me...

Page 6: ...ssories Available on request q Spindle holder q Frequency converter q Chiller q Collet grease q Further accessories on request Only approved accessories have been tested for operational safety and func tionality Ü Do not use any other accessories this may invalidate any warranty claims and compensation claims for damages Ü If the spindle holder is to be produced in house it is essential to contact...

Page 7: ...d a frequency con verter 3 1 Permissible types of machining The HF spindle has been developed only for the following types of machining q Cutting q Drilling q Engraving q Grinding Ü Contact Nakanishi Jaeger GmbH if other types of machining are required 3 2 Permissible materials The HF spindle has been developed only for the following materials q Metals such as alloys cast metals etc q Sintered mat...

Page 8: ...are not approved for use in areas at risk of explosion Use in such areas may result in explosions u Do not use the HF spindle in potentially explosive atmospheres DANGER Due to flying parts The HF spindle operates at high speeds and may therefore be flung away by these u Operate the HF spindle only if it is installed in the machine or system in a fixed manner Note Adhere to the limit values u Obse...

Page 9: ...use chips to fly out with great force u Never remove the protective devices of the machine or system u Always wear protective goggles during work Example of design Inserting the shank Note Ensure functionality u Never operate the HF spindle without a clamped tool shank If no tool shank is clamped q The clamping system is damaged by the centrifugal forces q The clamping system is shifted q The bala...

Page 10: ... forwarding this to the machine controller for evaluation 4 3 Installation and maintenance Ü Carry out installation cleaning and maintenance work only after shutting down the HF spindle and after the shaft has come to a standstill Ü Install all safety and protective devices of the machine immediately after completing work 4 4 Modification and repair Modifications or alterations to the HF spindle a...

Page 11: ...ctrical connection for Motor phase V 1a W Electrical connection for Motor phase W 1a PE Electrical connection for PE protective conductor 1b Electrical connection for Tool taper monitoring KTY 1c Electrical connection for Vector control 2 Cooling water G 1 4 3 Sealing air G 1 8 4 Taper cleaning G 1 8 7 Pneumatics for tool change cylinder forward G 1 8 8 Pneumatics for tool change cylinder back G 1...

Page 12: ...r information The FC detects the following operating states of the HF spindle depending on the version q HF spindle rotating q HF spindle too hot q HF spindle at a standstill etc The FC forwards the operating states of the HF spindle to the machine con troller 5 3 Cooling Liquid cooling keeps the HF spindle at a constant temperature during opera tion Note Extension of the service life through heat...

Page 13: ... spindle 5 5 Taper cleaning For guidelines on air quality see Air purity classes ISO 8573 1 26 section Taper cleaning prevents chips and liquids from entering the shaft during a tool change and causing contamination and damage to the inner taper and the clamping system 5 6 Pneumatic tool change For guidelines on air quality see Air purity classes ISO 8573 1 26 section The tool change or tool taper...

Page 14: ... pairs 2 Rated rotation speed 24 000 rpm Acceleration braking value Per second 10 000 rpm other values by consultation Characteristics Speed sensor Vector control Toothed wheel Teeth 256 Module 0 3 Motor protection PTC 145 C Housing Stainless steel Housing diameter 120 mm Cooling Liquid cooled Ambient temperature 10 C 45 C Sealing air Protection category sealing air turned on IP54 Taper cleaning T...

Page 15: ...018 Revision 03 15 44 Coupler plug 4 cables Cable length 1 m motor phases 17 pin metal Cable length 0 2 m sensors 12 pin ECTA 133 Cable length 1 m sensors Weight 23 kg Inner taper run out 1 µ Axial run out 1 µ 6 1 Dimensions Clamping range ...

Page 16: ...00 24 000 rpm Speed 4 600 9 600 14 600 19 600 23 600 rpm Frequency 167 333 500 667 800 Hz Rated power 3 6 7 5 11 5 15 4 18 5 kW Torque 7 5 7 5 7 5 7 5 7 5 Nm Voltage 85 160 220 295 350 V Current 47 47 47 47 47 A S6 60 Rated rotation speed 5 000 10 000 15 000 20 000 24 000 rpm Speed 4 600 9 600 14 600 19 600 23 600 rpm Frequency 167 333 500 667 800 Hz Rated power 4 1 8 5 13 17 4 21 kW Torque 8 5 8 ...

Page 17: ...Technical Specifications Item no 10408018 Revision 03 17 44 6 2 1 Performance Diagram ...

Page 18: ...chn Nr EE 19 06 2015 Alfred Jäger GmbH Siemensstraße 8 61239 Ober Mörlen PTC WK 29031271 Kabelabgang WK PTC PNP 0V Vs PNP output Vs 0V 0V Vs PNP output output 0 14 mm 0 14 mm 0 14 mm 0 14 mm 0 14 mm 0 14 mm 0 14 mm 0 14 mm 0 14 mm 0 14 mm 0 14 mm 0 38 mm 0 38 mm 0 38 mm 0 38 mm 0 5 mm 0 38 mm 0 38 mm 0 38 mm 0 38 mm 0 5 mm 0 5 mm 0 5 mm 12x0 14mm Induktiver Sensor inductive sensor Induktiver Senso...

Page 19: ... Kabelplan S12 12x0 14mm A B E F G C D H J K L M 23 07 2015 J A H K B G M L C F E D K H G M F D L PTC PTC J KTY 3x A B 3x C KTY E 0 14 mm 0 14 mm 0 14 mm 0 14 mm 0 14 mm 0 14 mm 0 14 mm 0 14 mm 0 14 mm 0 14 mm 0 14 mm 0 14 mm gelb yellow braun brown grün green rot red blau blue schwarz black Spindelstecker S12 ECTA 133 Spindle plug S12 ECTA 133 Steuerleitung control cable violett purple weiß white...

Page 20: ...5 mm wird nicht benötigt isoliert hineinlegen not connected isolated YE 0 25 mm BK 0 25 mm WH 0 25 mm BN 0 25 mm GY 0 25 mm BU 0 25 mm RD 0 25 mm PK 0 25 mm 2 0 1 Perschewski 16 03 17 1 29022570 g f e d c b a 4 5 6 1 3 2 a b c d e f g Bl Übersetzungen Vervielfältigungen und die Weitergabe an Dritte auch nur auszugsweise ist ohne schriftliche Gehnehmigung der Fa Nakanishi Jaeger GmbH untersagt Datu...

Page 21: ... voltage Vis 3 kV Response time ta 2 5 s Operating temperature range V 0 Top 25 180 C Resistance values TNAT ΔT R TNAT ΔT VPTC 2 5 V R TNAT ΔT VPTC 2 5 V R TNAT 15 K VPTC 7 5 V R TNAT 23 K VPTC 2 5 V 145 5 C 550 Ω 1330 Ω 4 kΩ 6 5 Tool change monitoring Tool taper monitoring indicates the readiness status of the HF spindle to the operator and forwards the corresponding signal to the machine control...

Page 22: ...hnical Specifications Output level 1 VSS as differential signal Output signal 2 sinusoidal signals offset by 90 and their inverse signals short circuit proof Option reference pulse Output frequency 0 200 kHz for a line capacity of 5 nF Offset static 20 mV Amplitude tolerance 20 10 Amplitude synchronization USp1 USp2 0 9 1 1 Supply voltage UB 5 VDC 5 Power consumption without load 0 3 W Cable lengt...

Page 23: ...sk of injury due to flying parts The HF spindle operates at high speeds which may cause chips to fly out with great force u Never remove the protective devices of the machine or system u Always wear protective goggles during work Example of design Mounting surface Note the following points before installing the HF spindle Ü Make sure that the correct spindle holder for the HF spindle is fitted in ...

Page 24: ...esponding hoses in the hose fittings Ü Make sure that the connections are flexible and free of strain Ü Seal all connections for compressed air axially in relation to the tightening direction Ü Seal all connections for cooling water axially in relation to the tightening direction Ü If the HF spindle is equipped with sealing air Ä Make sure that no air flow can occur in the bearing area Ä Always us...

Page 25: ... immediate corrosion on bare parts which is often unno ticeable at first but later leads to serious corrosion damage Ü Do not use pure or distilled water Deposits in cooling channels due to unsuitable cooling water prevent the dis sipation of heat Ü Use cooling water with the following properties Drinking water according to 98 83 EC Hardness 1 15 dH PH value 7 9 Additive corrosion protection 20 An...

Page 26: ... air quality see Air purity classes ISO 8573 1 26 section The adjustment value for the sealing air depends on the hose diameter and length Ü Hose diameter DN 4 Ü The setting value can be found in the following diagram Ü To ensure effective control turn on the sealing air and cooling when turn ing on the machine This protects the HF spindle even when it is stationary Lowest sealing air supply Dry m...

Page 27: ...o 10408018 Revision 03 27 44 8 4 3 Setting values For guidelines on air quality see Air purity classes ISO 8573 1 26 section Ü Keep to the following values Taper cleaning 4 5 6 bar Pneumatic system for tool change 6 0 bar ...

Page 28: ...entrifugal forces q The clamping system is shifted q The balance of the HF spindle is affected q The bearing is damaged Ü Turn the shaft of the spindle at least ten times by hand Ü Before storing and before commissioning only clean the cooling duct with compressed air 9 1 Running in schedule Duration of load minutes Max load Ü Put the HF spindle into operation with a clamped tool without machining...

Page 29: ...ing this to the machine controller for evaluation 9 4 Commissioning after storage Ü Do not put the HF spindle into operation until its temperature has adjusted from the temperature of the storage location to the temperature of the us age location Ä The temperature difference between the HF spindle and the usage lo cation should not exceed 10 C Ü Carry out all steps in the Maintenance 36 section Ü ...

Page 30: ...The clamping system is damaged by the centrifugal forces q The clamping system is shifted q The balance of the HF spindle is affected q The bearing is damaged 10 1 Clockwise and counter clockwise Sample illustration Direction of rotation indication The HF spindle clamping system is designed for clockwise and counter clock wise rotation Ü Only use tools with the correct direction of rotation for th...

Page 31: ...age and clean when switching to the HF spindle Insert the tool up to the contact surface of the clamping taper Ü Make sure that the shaft of the HF spindle has come to an absolute stand still Ü Switch on the compressed air for cylinder forward Ü Remove the tool Ü Clean the inner taper of the tool mount and the inner taper of the shaft with the felt cleaning taper Ü Insert the tool Ä Insert the too...

Page 32: ...ic taper change During a tool change the tool mount is pressed out of the shaft by the cylin der 10 3 2 Installing the changing station Proceed as follows to install the changing station Ü Drill a hole with a suitable diameter Ø D1 H7 for the tool mount Ü Add an M5 thread Ü Insert the changing station into the hole Ü Secure the changing station using the threaded spindle M5 10 3 3 Maintenance Befo...

Page 33: ... Tool change at the HF spindle Caution No rotation without clamped tool Tool clamped signal HF spindle is ready for use No Connection on off Compressed air Always leave sealing air switched on Even in the case of a tool change This prevents dirt or moisture from entering the HF spindle 3 Taper cleaning on 4 Pneumatic system for tool change on Cylinder forward 7 Perform tool change Taper cleaning o...

Page 34: ...rt HF spindle Clamped signal Cylinder back Clamping system clamped with tool Tool taper inserted in tool mount of HF spindle 1 Start HF spindle when signal 1 Ejected signal Cylinder is extended Clamping system disengaged Tool taper inserted in tool mount of HF spindle Tool taper is not clamped here 0 Do not start HF spindle Note Ensure functionality The released signal shows the user the ready sta...

Page 35: ...may be flung out u Note the maximum speed for the selected tool u Note the maximum speed for the HF spindle u The maximum permissible speed of the HF spindle for commissioning processing is always the lowest specified speed Ü Only use tools that are technically sound Ü Only use tools with a tool shank diameter that corresponds to the inner di ameter of the collet For example do not use shanks with...

Page 36: ...rately all contact sur faces of the HF spindle the mount for the HF spindle the tool mount and the tool holder must be clean Note Foreign matter reduces the service life u Do not use compressed air to clean the HF spindle u Do not use ultrasonic cleaning on the HF spindle u Do not use steam jets to clean the HF spindle This could cause contamination to enter the bearing area 12 2 1 Before commenci...

Page 37: ...izontal position Ü Store the HF spindle so that it is protected from moisture dust and other environmental influences Ü Note the following storage conditions Temperature of storage location 10 C 45 C Relative humidity 50 12 4 Monthly maintenance Ü Turn the shaft of the HF spindle at least ten times by hand every four weeks 12 5 Long periods of storage Ü Turn the shaft of the HF spindle at least te...

Page 38: ...ion More than 90 of the materials used in the HF spindle can be recycled alu minum stainless steel steel copper etc The HF spindle may not be disposed of with normal domestic waste Ü Remove all non recyclable materials Ü Dispose of the HF spindle as scrap at an approved recycling facility Ü Follow all rules of the responsible administrative bodies Ü Do not discharge coolants into wastewater Ü Disp...

Page 39: ... energy supply companies u Before commencing work switch off the power supply of the HF spindle Note Damage due to electrostatic discharge Do not touch the electrostatic sensitive components of the HF spindle 14 1 Service partners Only certified service partners may open and repair the spindle Failure to comply with this voids any warranty claims and compensation claims for dam ages Ü The list of ...

Page 40: ...requency converter has shut down q Check the error messages in the frequency converter man ual Tool change initiated q Turn off the pneumatic system for the tool change HF spindle becomes hot Cause Troubleshooting Insufficient cooling q Check the power of the chiller q Check the water level of the chiller q Check the connections and the cooling hoses q Check the cooling circuit q Check the chiller...

Page 41: ...tly q Only tighten the clamping screws of the spindle holder manually q Do not use technical aids to clamp the HF spindle Bearings damaged q Contact Nakanishi Jaeger GmbH service No automatic tool change Cause Troubleshooting Contamination q Remove all contamination between the tool taper and shaft of the HF spindle Observe all points in the Tool change 30 and Mainte nance 36 sections Collet does ...

Page 42: ...or damage q Replace damaged tool Contamination q Remove all contamination between the tool taper and shaft of the HF spindle Observe all points in the Tool change 30 and Mainte nance 36 sections Frequency converter incorrectly set q Compare the values for the HF spindle with the set values on the frequency converter Machining too heavy q Reduce the machining load intensity Mounting screws are loos...

Page 43: ... 5 1 5 6 1 5 8 1 5 9 1 6 4 1 6 5 1 7 1 1 7 1 1 1 7 2 1 7 3 1 7 4 The incomplete machinery in its standard design complies furthermore with the following applicable regulations Applicable harmonized standards DIN EN ISO 12100 Safety of machines The machinery is incomplete and must not be put into service until the ma chinery into which it is to be incorporated has been declared in conformity with t...

Page 44: ...rlen GERMANY 49 0 6002 9123 0 sales anakanishi jaeger com www nakanishi jaeger com Serial number Type Z120 H824 06 K1W2V Item no 10408018 Revision 03 Date 01 09 2023 Language EN Jaeger Spindles North America Corp 6611 Bay Circle Suite 165 Norcross GA 30071 USA 1 770 674 4480 office jaegerspindles com www nakanishi jaeger com en ...

Reviews: