background image

Technical description

Item no. 15201039-02, Revision 03

10 ( 36 )

5

Technical description

5.1

Connections of HF spindle

1

3

1

Electrical connection

3

Sealing air

M5

5.2

Electrical connection

The HF spindle may only be operated with a frequency converter (FC).

Ü

Check whether the current, voltage, and frequency data of the HF spindle
match the raw data for the frequency converter.

Ü

Use a motor supply line that is as short as possible.

Ü

Adjust the speed of the HF spindle using the FC.

Ü

Refer to the frequency converter manual for further information.

The FC detects the following operating states of the HF spindle, depending on
the version:

q

HF spindle rotating.

q

HF spindle too hot.

q

HF spindle at a standstill, etc.

The  FC  forwards  the  operating  states  of  the  HF  spindle  to  the  machine  con-
troller.

Summary of Contents for Z33-M060.51 K0,15 S15

Page 1: ...Manual Z33 M060 51 K0 15 S15 High Frequency Spindle Manual tool change ...

Page 2: ... logical development we reserve the right to make technical modifications and variations from the exact design described in the manual The text in this manual has been compiled with the utmost care However Nakanishi Jaeger GmbH cannot assume any legal responsibility or liability of any kind for incorrect information and any consequences thereof Translations and reproductions including of extracts ...

Page 3: ...or data 17 6 3 1 Performance Diagram 18 6 3 2 Equivalent circuit diagram data 18 Parameter 19 6 4 Wiring diagram 20 6 5 Air borne noise emissions 21 7 Operating location 21 8 Installation 22 8 1 Installing the HF spindle 22 8 2 Diameter of media supply line 22 8 3 Compressed air 23 8 3 1 Air purity classes ISO 8573 1 23 8 3 2 Setting the sealing air 23 9 Commissioning 24 9 1 Running in schedule 24...

Page 4: ...ection of the man ual carefully again 1 2 Explanation of symbols used To enable quick classification of information this manual uses visual aids in the form of symbols and text markings Notes are marked with a signal word and a colored box DANGER Dangerous situation Results in serious injury or death u Measure to avert the danger WARNING Dangerous situation May result in serious injury or death u ...

Page 5: ...essories Available on request q Spindle holder q Frequency converter q Collet q Felt cleaning taper q Collet grease q Further accessories on request Only approved accessories have been tested for operational safety and func tionality Ü Do not use any other accessories this may invalidate any warranty claims and compensation claims for damages Ü If the spindle holder is to be produced in house it i...

Page 6: ...and a frequency con verter 3 1 Permissible types of machining The HF spindle has been developed only for the following types of machining q Cutting q Drilling q Engraving q Grinding Ü Contact Nakanishi Jaeger GmbH if other types of machining are required 3 2 Permissible materials The HF spindle has been developed only for the following materials q Metals such as alloys cast metals etc q Sintered m...

Page 7: ...s are not approved for use in areas at risk of explosion Use in such areas may result in explosions u Do not use the HF spindle in potentially explosive atmospheres DANGER Due to flying parts The HF spindle operates at high speeds and may therefore be flung away by these u Operate the HF spindle only if it is installed in the machine or system in a fixed manner Note Adhere to the limit values u Ob...

Page 8: ... chips to fly out with great force u Never remove the protective devices of the machine or system u Always wear protective goggles during work Example of design Inserting the shank Note Ensure functionality u Never operate the HF spindle without a clamped tool shank If no tool shank is clamped q The clamping system is damaged by the centrifugal forces q The clamping system is shifted q The balance...

Page 9: ...this to the machine controller for evaluation 4 3 Installation and maintenance Ü Carry out installation cleaning and maintenance work only after shutting down the HF spindle and after the shaft has come to a standstill Ü Install all safety and protective devices of the machine immediately after completing work 4 4 Modification and repair Modifications or alterations to the HF spindle are only perm...

Page 10: ...equency data of the HF spindle match the raw data for the frequency converter Ü Use a motor supply line that is as short as possible Ü Adjust the speed of the HF spindle using the FC Ü Refer to the frequency converter manual for further information The FC detects the following operating states of the HF spindle depending on the version q HF spindle rotating q HF spindle too hot q HF spindle at a s...

Page 11: ...e heat generated must be dissi pated via the spindle holder optional accessory If the spindle holder is to be produced in house Ü Contact Nakanishi Jaeger GmbH Ü Request the tolerances and production plan for the spindle holder Ü Produce the spindle holder from a thermally conductive material e g alu minum Ü Observe the dimensions of the clamping range in the Technical Specifica tions 12 section M...

Page 12: ...kW Torque 0 08 0 075 0 06 Nm Voltage 47 47 44 V Current 8 2 7 8 8 1 A Motor data Motor technology 3 phase asynchronous drive no brushes or sensors Frequency 1 000 Hz Motor poles pairs 1 Rated rotation speed 60 000 rpm Acceleration braking value Per second 10 000 rpm other values by consultation Characteristics Housing Aluminium Housing diameter 33 mm Cooling Uncooled Heat dissipation Via the spind...

Page 13: ...Technical Specifications Item no 15201039 02 Revision 03 13 36 Clockwise Coupler plug 7 pin Amphenol C16 1 Cable length 0 15 m Weight 0 62 kg Inner taper run out 1 µ 6 1 Dimensions Clamping range ...

Page 14: ... Rated rotation speed 5 000 10 000 30 000 60 000 rpm Speed 2 905 7 888 27 887 57 985 rpm Frequency 83 167 500 1 000 Hz Rated power 0 025 0 066 0 223 0 431 kW Torque 0 0817 0 0802 0 0765 0 0709 Nm Voltage 7 12 29 57 V Current 8 2 8 2 8 2 8 6 A cos φ 0 93 0 87 0 8 0 73 S6 60 Rated rotation speed 5 000 10 000 30 000 60 000 rpm Speed 2 720 7 755 27 744 57 588 rpm Frequency 83 167 500 1 000 Hz Rated po...

Page 15: ...ntal voltage must correspond to the specified motor voltage The measured currents may be greater than the specified values due to the harmonic content 6 2 1 Performance Diagram 6 2 2 Equivalent circuit diagram data Note Damage due to incorrect performance data The values of the parameters relate exclusively to the motor u HF spindle values See tables S1 100 S6 60 and S2 Pmax ...

Page 16: ...5 Cooling type Spindle holder cooled p0341 Moment of inertia 0 0000053 kgm p0348 Field weakening operating speed VDC 600V 253 070 rpm p0350 Stator resistance cold strand 0 238 Ω p0353 Series inductance strand 0 mH p0354 Rotor resistance cold 0 136 Ω p0356 Stator stray inductance 0 058 mH p0358 Rotor stray inductance 0 083 mH p0360 Main inductance 0 89 mH p0604 Motor temperature warning threshold 8...

Page 17: ...peed 5 000 10 000 20 000 30 000 40 000 50 000 60 000 rpm Speed 3 953 8 458 18 000 27 953 37 806 47 954 58 182 rpm Frequency 83 167 333 500 667 833 1 000 Hz Rated power 0 022 0 053 0 112 0 169 0 207 0 232 0 245 kW Torque 0 0536 0 0603 0 0595 0 0577 0 0522 0 0462 0 0403 Nm Voltage 8 11 18 25 31 37 44 V Current 8 1 6 7 6 8 6 8 6 5 6 1 5 6 A cos φ 0 85 0 84 0 83 0 81 0 81 0 79 0 77 Measured values S6 ...

Page 18: ...87 0 349 0 406 kW Torque 0 073 0 0799 0 0778 0 0754 0 072 0 0699 0 067 Nm Voltage 7 12 19 28 35 40 47 V Current 7 7 8 2 8 2 8 1 8 8 1 8 A cos φ 0 91 0 87 0 83 0 8 0 8 0 82 0 81 Note on operation with static frequency converters For operation with a frequency converter the effective fundamental voltage must correspond to the specified motor voltage The measured currents may be greater than the spec...

Page 19: ... 71 Arms p0322 Maximum speed 60 000 rpm p0326 Stalling torque correction factor 100 p0335 Cooling type Uncooled p0341 Moment of inertia 0 0000053 kgm p0348 Field weakening operating speed VDC 600V 324 887 rpm p0350 Stator resistance cold strand 0 238 Ω p0353 Series inductance strand 0 mH p0354 Rotor resistance cold 0 136 Ω p0356 Stator stray inductance 0 087 mH p0358 Rotor stray inductance 0 121 m...

Page 20: ...KTY BU PTC 0 14mm BN KTY RD PTC 0 14mm Stator KTY PTC Spindel 1 3 5 PE 6 2 BN 0 5 mm GN 0 5 mm WH 0 5 mm YE 0 5 mm GY 0 5 mm PK 0 5 mm Motorkabel 7x0 5mm motor cable 7x0 5mm 1 0 4 1 Perschewski 14 09 16 1 29043670 g f e d c b a 4 5 6 1 3 2 a b c d e f g Bl Übersetzungen Vervielfältigungen und die Weitergabe an Dritte auch nur auszugsweise ist ohne schriftliche Gehnehmigung der Fa Nakanishi Jaeger ...

Page 21: ...isk of injury due to flying parts The HF spindle operates at high speeds which may cause chips to fly out with great force u Never remove the protective devices of the machine or system u Always wear protective goggles during work Example of design Mounting surface Note the following points before installing the HF spindle Ü Make sure that the correct spindle holder for the HF spindle is fitted in...

Page 22: ...se fittings Ü Make sure that the connections are flexible and free of strain Ü Seal all connections for compressed air axially in relation to the tightening direction Ü If the HF spindle is equipped with sealing air Ä Make sure that no air flow can occur in the bearing area Ä Always use sealed cable boxes when connecting electrical lines Ü Mount the HF spindle on the machine Ü Connect the hoses to...

Page 23: ... air quality see Air purity classes ISO 8573 1 23 section The adjustment value for the sealing air depends on the hose diameter and length Ü Hose diameter DN 2 8 Ü The setting value can be found in the following diagram Ü To ensure effective control turn on the sealing air and cooling when turn ing on the machine This protects the HF spindle even when it is stationary Lowest sealing air supply Dry...

Page 24: ...mping system is damaged by the centrifugal forces q The clamping system is shifted q The balance of the HF spindle is affected q The bearing is damaged Example of design Clockwise Ü Turn the shaft of the spindle at least ten times by hand 9 1 Running in schedule Duration of load minutes Max load Ü Put the HF spindle into operation with a clamped tool without machining for approx 10 minutes Ü The s...

Page 25: ...ding this to the machine controller for evaluation 9 4 Commissioning after storage Ü Do not put the HF spindle into operation until its temperature has adjusted from the temperature of the storage location to the temperature of the us age location Ä The temperature difference between the HF spindle and the usage lo cation should not exceed 10 C Ü Carry out all steps in the Maintenance 29 section Ü...

Page 26: ...amaged 10 1 Clockwise Sample illustration Direction of rotation indication The HF spindle clamping system is designed for clockwise rotation Ü Only use tools with the correct direction of rotation for the HF spindle Ü Only use tool mounts with the correct HF spindle direction of rotation Ü Set the direction of rotation of the HF spindle on the FC in accordance with the arrow display on the HF spin...

Page 27: ...ool Ü Make sure that the shank of the clamped tool does not press on the inner stop of the tool mount once the clamping nut has been tightened Ü To prevent the clamping nut from loosening tighten it again after a short period of operation and when the shaft is at a standstill 10 2 1 Maximum tightening torques Short clamping bore Continuous clamping bore Excessive tightening torques MA can damage o...

Page 28: ...s may be flung out u Note the maximum speed for the selected tool u Note the maximum speed for the HF spindle u The maximum permissible speed of the HF spindle for commissioning processing is always the lowest specified speed Ü Only use tools that are technically sound Ü Only use tools with a tool shank diameter that corresponds to the inner di ameter of the collet For example do not use shanks wi...

Page 29: ... to the openings of the HF spindle 12 2 Daily cleaning To ensure that the HF spindle functions safely and accurately all contact sur faces of the HF spindle the mount for the HF spindle the tool mount and the tool holder must be clean Note Foreign matter reduces the service life u Do not use compressed air to clean the HF spindle u Do not use ultrasonic cleaning on the HF spindle u Do not use stea...

Page 30: ...ected from moisture dust and other environmental influences Ü Note the following storage conditions Temperature of storage location 10 C 45 C Relative humidity 50 12 4 Monthly maintenance Ü Turn the shaft of the HF spindle at least ten times by hand every four weeks 12 5 Long periods of storage Ü Turn the shaft of the HF spindle at least ten times by hand every three months Ü Then put the HF spind...

Page 31: ...odies If the HF spindle cannot be dismantled send the HF spindle to Nakanishi Jaeger GmbH Nakanishi Jaeger GmbH shall not assume the costs incurred for shipment and the fees for the recycling facilities 14 Service and repairs DANGER Electric shock Electric shock can lead to severe burns and life threatening injuries Take measures to prevent hazards caused by electrical energy for details re fer e ...

Page 32: ...erter See also Spindle becomes hot 32 Frequency converter has shut down q Check the error messages in the frequency converter man ual HF spindle becomes hot Cause Troubleshooting Insufficient cooling q Check the power of the chiller q Check the water level of the chiller q Check the connections and the cooling hoses q Check the cooling circuit q Check the chiller for error messages Phase missing q...

Page 33: ...uly or is dis torted q Only use spindle holders from the original accessories or holders produced according to the tolerances specified by Nakanishi Jaeger GmbH HF spindle clamped too tightly q Only tighten the clamping screws of the spindle holder manually q Do not use technical aids to clamp the HF spindle Bearings damaged q Contact Nakanishi Jaeger GmbH service Sensor does not send any signals ...

Page 34: ...erve all points in the Tool change 26 and Mainte nance 29 sections Frequency converter incorrectly set q Compare the values for the HF spindle with the set values on the frequency converter Machining too heavy q Reduce the machining load intensity Mounting screws are loose q Tighten the screws securely HF spindle damaged q Contact Nakanishi Jaeger GmbH service If the error is not rectified after c...

Page 35: ...1 5 5 1 5 6 1 5 8 1 5 9 1 6 4 1 6 5 1 7 1 1 7 1 1 1 7 2 1 7 3 1 7 4 The incomplete machinery in its standard design complies furthermore with the following applicable regulations Applicable harmonized standards DIN EN ISO 12100 Safety of machines The machinery is incomplete and must not be put into service until the ma chinery into which it is to be incorporated has been declared in conformity wit...

Page 36: ...n GERMANY 49 0 6002 9123 0 sales anakanishi jaeger com www nakanishi jaeger com Serial number Type Z33 M060 51 K0 15 S15 Item no 15201039 02 Revision 03 Date 01 09 2023 Language EN Jaeger Spindles North America Corp 6611 Bay Circle Suite 165 Norcross GA 30071 USA 1 770 674 4480 office jaegerspindles com www nakanishi jaeger com en ...

Reviews: