Technical Specifications
Item no. 10404111, Revision 12
20 ( 40 )
6.5
Speed sensor (digital differential magneto resistor)
Trouble-free evaluation requires good wiring.
Ü
Use twisted and shielded cables.
Ü
Connect the HF spindle based on the connection example shown below.
DFP = digital differential magneto
resistor
S = signal
Note: Resistor (Rx).
If the resistor (Rx*) is already integrated in the evaluation unit (FC):
u
Only connect signal and ground.
Supply voltage (U)
Rx (*)
Signal (**)
+ 8 V
220 Ω
1000 mV
+ 8 V
450 Ω
2000 mV
+ 12 V
220 Ω
1000 mV
+ 12 V
680 Ω
3000 mV
+ 15 V
220 Ω
1000 mV
+ 15 V
680 Ω
3000 mV
+ 24 V
220 Ω
1000 mV
+ 24 V
680 Ω
3000 mV
*Unnecessary if a resistor is integrated in the evaluation unit (frequency converter, etc.).
**Values may differ by ±20% depending on the measuring method.
6.6
Air-borne noise emissions
CAUTION: Noise has an impact on health.
u
Only operate the HF spindle if you are wearing hearing protection.