Installation
Item no. 10404231, Revision 07
22 ( 40 )
8
Installation
Before installation:
Ü
Check the HF spindle for damage and ensure that it is complete.
If the HF spindle has been stored for a long period:
Ü
Carry out all steps in the Commissioning after storage section.
8.1
Installing the HF spindle
Connect media and cables with a
flexible connection.
Complete the following steps in sequence to install the HF spindle:
Ü
Remove the sealing plugs that protect the connections against damage
and contamination during transportation.
Ü
Instead of these sealing plugs, install the appropriate hose fittings.
Ü
Install the corresponding hoses in the hose fittings
Ü
Make sure that the connections are flexible and free of strain.
Ü
Seal all connections for compressed air axially in relation to the tightening
direction.
Ü
Seal all connections for cooling water axially in relation to the tightening
direction.
Ü
If the HF spindle is equipped with sealing air:
Ä
Make sure that no air flow can occur in the bearing area.
Ä
Always use sealed cable boxes when connecting electrical lines.
Ü
Mount the HF spindle on the machine.
Ü
Connect the hoses to the connection of the respective media.
Ü
Connect the connector of the operating connection lines to the relevant
connection of the HF spindle and to the frequency converter.
Ü
Lock the connectors.
Note: Connect the SpeedTEC quick locking connector.
u
For the combination SpeedTEC connector plug/SpeedTEC cable plug:
u
Remove the O ring on the SpeedTEC connector plug.