background image

Technical Specifications

Item no. 10205102, Revision 05

14 ( 36 )

6.2

Technical data sheet (KL7003 , AC-Motor)

The power values (S1, S6, S2)
are valid for sinusoidal cur-
rents and voltages.

The power values of the HF
spindle are dependent on the
frequency converter used and
may vary from the indicated
values.

Motor type

7/7-4

Rated power

4,6 kW

Rated rotation speed

30.000 rpm

Cooling

Liquid cooled

Motor protection

PTC 160°C

Winding resistance

1,6 Ω

Measured values: S1-100%

Rated rotation speed

5.000

10.000

15.000

20.000

25.000

30.000

rpm

Speed

3.888

8.766

14.002

18.910

23.868

28.294

rpm

Frequency

167

333

500

667

833

1.000

Hz

Rated power

0,766

1,671

2,641

3,398

4,043

4,621

kW

Torque

1,88

1,82

1,8

1,72

1,62

1,56

Nm

Voltage

86

154

228

297

366

365

V

Current

10

10

10

10

10

10

A

Cos φ

0,25

0,41

0,57

0,67

0,71

0,8

Measured values: S6-60%

Rated rotation speed

5.000

10.000

15.000

20.000

25.000

30.000

rpm

Speed

3.892

8.902

13.816

18.793

23.522

28.362

rpm

Frequency

167

333

500

667

833

1.000

Hz

Rated power

0,821

1,876

2,816

3,792

4,644

5,156

kW

Torque

2,02

2,01

1,95

1,93

1,89

1,74

Nm

Voltage

85

153

221

289

353

354

V

Current

11

11

11

11

11

11

A

Cos φ

0,88

0,83

0,8

0,79

0,78

0,86

Summary of Contents for Z80-M530.03 S6

Page 1: ...Manual Z80 M530 03 S6 High Frequency Spindle Manual tool change...

Page 2: ...velopment we reserve the right to make technical modifications and variations from the exact design described in the manual The text in this manual has been compiled with the utmost care However Nakan...

Page 3: ...Speed sensor digital differential magneto resistor 18 6 6 Air borne noise emissions 18 7 Operating location 19 8 Installation 20 8 1 Installing the HF spindle 20 8 2 Diameter of media supply line 21 8...

Page 4: ...of the man ual carefully again 1 2 Explanation of symbols used To enable quick classification of information this manual uses visual aids in the form of symbols and text markings Notes are marked with...

Page 5: ...Optional accessories Available on request q Spindle holder q Frequency converter q Chiller q Collet q Collet grease q Further accessories on request Only approved accessories have been tested for oper...

Page 6: ...nd a frequency con verter 3 1 Permissible types of machining The HF spindle has been developed only for the following types of machining q Cutting q Drilling q Engraving q Grinding Contact Nakanishi J...

Page 7: ...re not approved for use in areas at risk of explosion Use in such areas may result in explosions u Do not use the HF spindle in potentially explosive atmospheres DANGER Due to flying parts The HF spin...

Page 8: ...ause chips to fly out with great force u Never remove the protective devices of the machine or system u Always wear protective goggles during work Example of design Inserting the shank Note Ensure fun...

Page 9: ...the machine controller for evaluation 4 3 Installation and maintenance Carry out installation cleaning and maintenance work only after shutting down the HF spindle and after the shaft has come to a s...

Page 10: ...voltage and frequency data of the HF spindle match the raw data for the frequency converter Use a motor supply line that is as short as possible Adjust the speed of the HF spindle using the FC Refer t...

Page 11: ...The temperature of the HF spindle should not exceed 45 C as this shortens the service life of the bearing u Check the temperature of the HF spindle on the housing 5 4 Sealing air For guidelines on air...

Page 12: ...ency 1 000 Hz Motor poles pairs 2 Rated rotation speed 30 000 rpm Acceleration braking value Per second 10 000 rpm other values by consultation Characteristics Speed sensor Differential magneto resist...

Page 13: ...Technical Specifications Item no 10205102 Revision 05 13 36 6 1 Dimensions Clamping range...

Page 14: ...5 000 10 000 15 000 20 000 25 000 30 000 rpm Speed 3 888 8 766 14 002 18 910 23 868 28 294 rpm Frequency 167 333 500 667 833 1 000 Hz Rated power 0 766 1 671 2 641 3 398 4 043 4 621 kW Torque 1 88 1 8...

Page 15: ...9 2 333 3 842 5 425 6 871 6 893 kW Torque 2 41 2 86 2 93 2 94 2 87 2 43 Nm Voltage 81 151 217 286 351 348 V Current 14 15 15 15 15 16 A Cos 0 93 0 91 0 89 0 88 0 88 0 9 Note on operation with static f...

Page 16: ...sstra e 8 61239 Ober M rlen 29027270 Pinbel FS13 PTC DFP 3pol 04 11 2008 PE 5 6 10 1 8 3 0 14 mm 0 14 mm DFP Resistor 220 Ohm Widerstand 9 2 12 4 7 11 U W 0 75 mm 0 14 mm 0 14 mm 0 14 mm 0 14 mm 0 25...

Page 17: ...cording to the positive temperature coefficient thermistor temperature TPTC small signal resistance Technical Specifications Type M135 Max operating voltage TA 0 40 C V max 30 V Max measuring voltage...

Page 18: ...resistor Rx is already integrated in the evaluation unit FC u Only connect signal and ground Supply voltage U Rx Signal 8 V 220 1000 mV 8 V 450 2000 mV 12 V 220 1000 mV 12 V 680 3000 mV 15 V 220 1000...

Page 19: ...speeds which may cause chips to fly out with great force u Never remove the protective devices of the machine or system u Always wear protective goggles during work Example of design Mounting surface...

Page 20: ...gs install the appropriate hose fittings Install the corresponding hoses in the hose fittings Make sure that the connections are flexible and free of strain Seal all connections for compressed air axi...

Page 21: ...s immediate corrosion on bare parts which is often unno ticeable at first but later leads to serious corrosion damage Do not use pure or distilled water Deposits in cooling channels due to unsuitable...

Page 22: ...n air quality see Air purity classes ISO 8573 1 22 section The adjustment value for the sealing air depends on the hose diameter and length Hose diameter DN 4 The setting value can be found in the fol...

Page 23: ...al forces q The clamping system is shifted q The balance of the HF spindle is affected q The bearing is damaged Example of design Clockwise Turn the shaft of the spindle at least ten times by hand Bef...

Page 24: ...rding this to the machine controller for evaluation 9 4 Commissioning after storage Do not put the HF spindle into operation until its temperature has adjusted from the temperature of the storage loca...

Page 25: ...tool shank is clamped q The clamping system is damaged by the centrifugal forces q The clamping system is shifted q The balance of the HF spindle is affected q The bearing is damaged 10 1 Clockwise S...

Page 26: ...Clean the thread of the shaft u Clean the inner taper of the shaft Lightly grease the thread of the clamping nut Push the collet into the clamping nut until it engages in the groove pro vided for thi...

Page 27: ...ments may be flung out u Note the maximum speed for the selected tool u Note the maximum speed for the HF spindle u The maximum permissible speed of the HF spindle for commissioning processing is alwa...

Page 28: ...to the openings of the HF spindle 12 2 Daily cleaning To ensure that the HF spindle functions safely and accurately all contact sur faces of the HF spindle the mount for the HF spindle the tool mount...

Page 29: ...zontal position Store the HF spindle so that it is protected from moisture dust and other environmental influences Note the following storage conditions Temperature of storage location 10 C 45 C Relat...

Page 30: ...n More than 90 of the materials used in the HF spindle can be recycled alu minum stainless steel steel copper etc The HF spindle may not be disposed of with normal domestic waste Remove all non recycl...

Page 31: ...energy supply companies u Before commencing work switch off the power supply of the HF spindle Note Damage due to electrostatic discharge Do not touch the electrostatic sensitive components of the HF...

Page 32: ...er See also Spindle becomes hot 32 Frequency converter has shut down q Check the error messages in the frequency converter man ual HF spindle becomes hot Cause Troubleshooting Insufficient cooling q C...

Page 33: ...or is dis torted q Only use spindle holders from the original accessories or holders produced according to the tolerances specified by Nakanishi Jaeger GmbH HF spindle clamped too tightly q Only tigh...

Page 34: ...serve all points in the Tool change 25 and Mainte nance 28 sections Frequency converter incorrectly set q Compare the values for the HF spindle with the set values on the frequency converter Machining...

Page 35: ...1 5 6 1 5 8 1 5 9 1 6 4 1 6 5 1 7 1 1 7 1 1 1 7 2 1 7 3 1 7 4 The incomplete machinery in its standard design complies furthermore with the following applicable regulations Applicable harmonized stand...

Page 36: ...rlen GERMANY 49 0 6002 9123 0 sales anakanishi jaeger com www nakanishi jaeger com Serial number Type Z80 M530 03 S6 Item no 10205102 Revision 05 Date 01 09 2023 Language EN Jaeger Spindles North Ame...

Reviews: