BM-141GE / BB-141GE
36
8.3.6 Note for 100BASE-TX connection
In order to use 100Mbps network, 100BASE-TX and Full Duplex are available. Half
Duplex cannot be used.
In the case of connecting on 100BASE-TX, the maximum packet size should be 1500
byte.
In the case the of connecting on 100BASE-TX, the specifications such as frame rate,
trigger interval and so on described in this manual cannot be satisfied.
Pixel Type
Frame rate at Full Frame scan[fps]
MONO8, BAYRG8, BAYGB8
8.0
~
8.2
MONO10_PACKED,MONO12_PACKED
5.4
~
5.6
MONO10, MONO12,BAYRG10,
BAYGB10,BAYRG12, BAYGB12
4.0
~
4.2
8.4. GigE camera connecting examples
8.4.1 Using a switching hub for 1 port
All cameras and NIC belong to the same subnet
The accumulated transfer rate for all cameras should be within 800Mbps
The packet size and the packet delay should be set appropriately in order
for the data not to overflow in the switching hub.