BM-141GE / BB-141GE
48
10.3.2 Edge Pre-select (EPS) Trigger Mode
An external trigger pulse initiates the capture, and the exposure time (accumulation time) is
the fixed shutter speed set by registers. The accumulation can be LVAL synchronous or LVAL
asynchronous. The resulting video signal will start to be read out after the selected shutter
time.
For timing details, refer to fig. 19. through fig.24 and figures 29 and 30.
To use this mode:
Important notes on using this mode
Trigger pulse >2 LVAL to <1 FVAL)
The following table shows minimum trigger interval in synchronous accumulation mode
Full scan
1054 L
2/3 Partial
774 L
1/2 Partial
635L
1/4 Partial
427 L
1/8 Partial
323 L
1/2 V Binning
529 L
In the case of asynchronous mode, the exposure time should be added to the above
table.